Chapter 5 View
Table 14 Status: Hardware Status
| LABEL | DESCRIPTION | 
| Device Name | This field displays the descriptive name of a device. | 
| 
 | 
 | 
| Device IP | This field displays the IP address of a device | 
| 
 | 
 | 
| Fan RPM | A properly functioning fan is an essential component (along with a sufficiently | 
| (RPM) | ventilated, cool operating environment) in order for the device to stay within the | 
| 
 | temperature threshold. Each fan has a sensor that is capable of detecting and | 
| 
 | reporting if the fan speed falls below the threshold shown. | 
| 
 | 
 | 
| Index | This field displays the fan number. | 
| 
 | 
 | 
| Current | This field displays this fan’s current speed in Revolutions Per Minute (RPM). | 
| 
 | 
 | 
| Max | This field displays this fan’s maximum speed recorded in Revolutions Per Minute | 
| 
 | (RPM). | 
| 
 | 
 | 
| Min | This field displays this fan’s minimum speed recorded in Revolutions Per Minute | 
| 
 | (RPM). | 
| 
 | 
 | 
| Threshold | This field displays the minimum speed at which a normal fan should work. | 
| 
 | 
 | 
| Status | NORMAL indicates that this fan is functioning above the minimum speed. ERROR | 
| 
 | indicates that this fan is functioning below the minimum speed. | 
| 
 | 
 | 
| Voltage (V) | The power supply for each voltage has a sensor that is capable of detecting and | 
| 
 | reporting if the voltage falls out of the tolerance range. | 
| 
 | 
 | 
| Index | This field displays the first voltage sensor number. | 
| 
 | 
 | 
| Current | This is the current voltage reading in volts. | 
| 
 | 
 | 
| Max | This field displays the maximum voltage recorded at this sensor in volts. | 
| 
 | 
 | 
| Min | This field displays the minimum voltage recorded at this sensor in volts. | 
| 
 | 
 | 
| Threshold | This field displays the minimum voltage percentage at which the switch should work. | 
| 
 | 
 | 
| Status | NORMAL indicates that the voltage is within an acceptable operating range at this | 
| 
 | point; otherwise ERROR is displayed. ABSENT indicates that there is no power | 
| 
 | reading at a sensor(s). | 
| 
 | 
 | 
| Temperature | The switch has temperature sensors that are capable of detecting and reporting if | 
| 
 | the temperature rises above the threshold. You may choose the temperature unit (in | 
| 
 | degrees Celsius or Fahrenheit). | 
| 
 | 
 | 
| Celsius | Select this option to display the temperature in degrees Centigrade. | 
| 
 | 
 | 
| Fahrenheit | Select this option to display the temperature in degrees Fahrenheit. | 
| 
 | 
 | 
| Index | This field displays the temperature sensor number. | 
| 
 | 
 | 
| Current | This shows the current temperature at this sensor. | 
| 
 | 
 | 
| Max | This field displays the maximum temperature recorded at this sensor. | 
| 
 | 
 | 
| Min | This field displays the minimum temperature recorded at this sensor. | 
| 
 | 
 | 
| Threshold | This field displays the upper temperature limit at this sensor. | 
| 
 | 
 | 
| Status | This field displays NORMAL for temperatures below the threshold and ERROR for | 
| 
 | those above. | 
| 
 | 
 | 
| Polling | The text box displays how often (in seconds) this screen refreshes. You may change | 
| 
 | the refresh interval by typing a new number in the text box and then clicking the | 
| 
 | Apply button. | 
| 
 | 
 | 
| Close | Click Close to close the screen. | 
| 
 | 
 | 
| 58 | 
 | |
| NetAtlas Workgroup User’s Guide | 
 | |
| 
 | 
 | 
 |