CLEANING THE EXHAUST PORT AND MUFFLER­

Depending on the type of fuel used, the type and amount of lubricant used, and/or your operating conditions, the exhaust port and muffler may become blocked with carbon deposits. If you notice a power loss with your gas-powered products, you may need to remove these deposits to restore perfor- mance. We highly recommend that only qualified service technicians perform this service.

spark arrestor

See Figure 25.

Inspect the spark arrestor for breaks or holes. Replace if necessary. To purchase a replacement spark arrestor contact RIDGID customer service at 1-866-539-1710.

Use a brush to remove carbon deposits from the spark arrestor screen as needed.

draining fuel tank/carburetor

See Figures 26 - 27.

To help prevent gum deposits in the fuel system, drain the fuel from the tank and carburetor before storing.

DRAINING THE FUEL TANK

Turn the engine switch key to “OFF”or press and hold the off switch until the engine stops.

Turn the fuel valve to the OFF position.

Remove the fuel line from the petcock by squeezing the ends of the retaining clip and sliding the fuel line off.

Install one end of a drain line over the petcock, and place the other end in a fuel container large enough to catch the fuel being drained from the tank.

Turn the fuel valve to the ON position.

For better fuel drainage, please tilt the unit toward the fuel petcock slightly (approximately 1 in.).

When the fuel has drained from the tank, close the fuel valve and reinstall fuel line securely on petcock.

draining the carburetor

Turn the engine switch key off or press and hold OFF switch in the OFF position for three (3) seconds or until the engine stops.

Turn the fuel valve to the OFF position.

Position a suitable container under the carburetor drain screw to catch fuel; loosen the screw.

Allow fuel to drain completely into container.

Retighten drain screw.

NOTE:  Consult hazardous waste management guidelines in your area for the proper way to dispose of used fuel.

Transporting

See Figure 28.

Turn the engine switch key switch off.

Turn the fuel valve to the OFF position.

Make sure engine and exhaust of unit is cool.

For security, insert the pin to secure the handle before transporting.

Keep unit level while transporting to prevent fuel spill- age.

Do not drop or strike unit or place under heavy objects.

18 — English

Image 18
Contents Neutral Bonded to Frame Portable GeneratorRD8000 / RD80011 Series / Série / Serie AVERTISSEMENT Table of Contents IntroductionImportant safety instructions Kill YOU in MinutesSpecific Safety Rules Symbols Symbol Signal MeaningSafety Labels Hot Surface warningSymbols ElectricalExtension cord Ground fault circuit interrupterElectric motor loads See FigurePower Management Generator CapacityFeatures Product SpecificationsKnow Your Generator Installing Legs AssemblyLoose Parts List Installing the wheelsInstalling a Wall Mount for the removable control panel AssemblyConnecting battery Removable Control PanelBefore Operating the Unit OperationApplications Raising and Lowering the HandleOxygenated Fuels Using fuel stabilizerChecking/adding fuel GenSmart Digital DisplayLifting the Generator Generator Control PanelMoving the Generator Electric StartStarting the engine Stopping the engineTo stop the engine under normal operating conditions Maintenance General MaintenanceDraining fuel tank/carburetor Cleaning the Exhaust Port and MUFFLER­Spark arrestor TransportingStorage MaintenanceMaintenance Schedule Storage time Prior to storingTroubleshooting Problem Possible Cause SolutionWhat is Covered Under the 3 Year Limited Warranty WarrantyYear Limited Warranty What is not CoveredLimited Manufacturer’s Warranty from Subaru Robin Warranty PeriodsEvaporative Emission Control Warranty Statement Table DES Matières Mise À LA Terre DU GénérateurArrière Instructions Importantes Concernant LA Sécurité AdvertissementConserver CES Instructions Règles de sécurité particulières Symboles Symbole Signal SignificationAvertissement Autocollants DE SÉCURITÉ­Avertissement Concernant Le lubrifiant Moteur Caractéristiques électriquesAvertissement Concernant LE Carburant Mise À LA Terre AvertissementDisjoncteur de fuite à la terre Charges du moteur électriqueCordon Prolongateur Voir la figureCapacité du générateur Gestion DE L’ÉNERGIECaractéristiques LISTe deS PIÈceS dÉTachÉe AssemblageAvertissement DéballageConnexion d’une pile Installation DES RouesPanneau de commande amovible Voir las figures 9 etRélever ET Abaisser LA Poignée UtilisationAvant D’UTILISER L’UNITÉ VÉRIFICATION/AJOUT de lubrifiantVÉRIFICATION/AJOUT DE Carburant Utilisation DE Stabilisateur DE CarburantCarburants Oxygénés Panneau de commande de la générateur Déplacement du génératriceSoulever LA Génératrice Démarrage Électrique Mise EN Marche DU MoteurArrêt DU Moteur INSPECTION/NETTOYAGE DU Filtre À AIR EntretienEntretien Général Entretien DE LA BougieVidange DU Réservoir DE CARBURANT/ Carburateur Nettoyage DE L’ORIFICE D’ÉCHAPPEMENT ET DU SilencieuxPARE-ÉTINCELLES TransportRemisage Calendrier D’ENTRETIENProblème Cause Possible Solution DépannageCE QUI EST Couvert PAR LA Garantie Limitée DE Trois ANS Garantie Limitée DE Service DE 3 ANSGarantie CE QUI N’EST PAS CouvertGarantie limitée de Subaru Robin Périodes DE GarantieResponsabilités DU Propriétaire Dans LE Cadre DE LA Garantie Peligro Conexión a tierra del generador Índice DE ContenidoIntroducción Pág. posteriorAdvertencia Instrucciones de seguridad importantesPeligro Guarde estas instruccionesReglas DE Seguridad Específicas Precaución SÍMBOLoSPeligro Símbolo Señal SignificadoEtiquetas DE Seguridad Advertencia de Superficie calienteAdvertencia del lubricante de motor Aspectos eléctricosAdvertencia de combustible Advertencia acerca de la conexión a tierraVea la figura Cargas de motores eléctricosCordón de extensión Para efectuar una pruebaAdministración DE LA Potencia Capacidad del generadorFamiliarícese CON EL Generador CaracterísticasEspecificaciones DEL Producto Tanque DE Combustible CON Indicador DE CargaDesempaquetado ArmadoLIsTa DE pIEzas sUElTas Instalación de lAS patasPanel de control desmontable Instalación de las ruedasConexión DE LA Batería Para quitar el panel de control desmontable del generadorAntes DE Accionar LA Unidad FuncionamientoAplicaciones LEvANTAR y BAjAR EL MANgOVerificación y abastecimiento de combustible Uso de estabililzador de combustible­Combustibles Oxigenados Panel de control general Traslado el generadorLevantar EL Generador Arranque eléctrico Arranque del motorApagado del motor Mantenimiento Mantenimiento GeneralDrenaje del tanque del combustible y del carburador Limpieza DEL Orificio DE Escape Y DEL SilenciadorParachispas TransporteAlmacenamiento Programa DE MantenimientoCorrección de problemas Problema Causa Posible SoluciónGarantía DE lIMITADA DE 3 Años GarantíaRidgid Generador LO QUE no Está CubiertoMotor CON Garantía Limitada DE 3 Años Cobertura DE LA Garantía DEL Fabricante RD8000/RD80011 Series / Série / Serie Customer Service InformationService après-vente  Información sobre servicio al consumidorPage Iii Axle essieu, eje OFF Start Engine Switch Page Fi g Combustible Off arret, apagado

RD80011, RD8000 specifications

The RIDGID RD8000 and RD80011 represent a significant advancement in the world of underground utility locating. These versatile tools are designed to help professionals accurately detect and trace buried utilities, ensuring safe and efficient excavation and construction processes.

Both models are equipped with advanced signal processing technologies that enhance their ability to locate utilities, even in challenging environments. The RD8000 is renowned for its range of frequencies—typically offering up to five different transmission frequencies, allowing users to locate a variety of utility types including electric, gas, water, and telecommunications lines. This frequency versatility means that users can effectively cater to a wide spectrum of application needs, from residential projects to large-scale infrastructure work.

The RD80011 variant enhances these capabilities with added features aimed at improving user experience and precision. One standout feature is the built-in GPS technology, which allows for real-time mapping and locating of utilities, providing users with the ability to track locations directly on their devices. This integration streamlines the process of recording and reporting utility locations, fostering efficient workflow and reducing the risk of errors in documentation.

Additionally, both models boast an ergonomic design, featuring a lightweight build and intuitive controls that make them user-friendly. The display screen is bright and easy to read, featuring visual indicators that help convey critical information at a glance. The RD8000 and RD80011 utilize a rechargeable battery that ensures long-lasting power, giving users the confidence to tackle extended projects without the need to frequently replace batteries.

Another valuable characteristic is the built-in earphone jack, allowing for enhanced audio feedback and communication in noisy environments. Users can listen for specific tones corresponding to different utilities, which can aid in pinpointing the location with greater accuracy.

These RIDGID models also include advanced interference suppression technologies to minimize signal distortion from other nearby utilities, ensuring users receive clear and accurate data. This feature is particularly vital in complex urban settings where multiple utilities coexist in close proximity.

In summary, both the RIDGID RD8000 and RD80011 are designed with professional utility locators in mind, integrating advanced technologies and features that enhance detection capabilities, improve ease of use, and contribute to safer excavation practices.