Dayton 2ZRP9, 2ZRP8 Installation, Assembly for Wheels Handles, Grounding Instructions

Page 4

Dayton Operating Instructions and Parts Manual

2ZRP8, 2ZRP9

Dayton® Generator

generator. Or, use a heavy duty,

Eoutdoor-rated extension cord that is

Nrated (in watts or amps) at least equal G to the sum of the connected appliance L loads. Check that the entire cord is free

Iof cuts or tears and that the plug has

Sall three prongs, especially a grounding H pin.

NEVER try to power the house wiring by plugging the generator into a wall outlet, a practice known as “back feeding”. This is an extremely dangerous practice that presents an electrocution risk to utility workers and neighbors served by the same utility transformer. It also bypasses some of the built-in household circuit protection devices.

If you must connect the generator to the house wiring to power appliances, have a qualified electrician install the appropriate equipment in accordance with local electrical codes. Or, check with your utility company to see if

it can install an appropriate power transfer switch.

For power outages, permanently installed stationary generators are better suited for providing backup power to the home. Even a properly connected portable generator can become overloaded. This may result in overheating or stressing the generator components, possibly leading to a generator failure.

Installation

ASSEMBLY FOR WHEELS AND

HANDLES:

Use the following items for installation: Isolator (3), Bolts (2), Locknut (1), Underbracket Assembly (4), Bolts (5), Washers (6), Collar/Shaft (8), Wheels (9),

Washers (10), Axle Bracket (7), Washers (12), Axle (11), Bolts (13), Handle Assembly (14), Locknut (15).

1.Raise the generator off the work surface to allow clearance to mount the Wheel Kit onto the unit.

NOTE: Make sure the generator is stable and secure before installing the Wheel Kit.

2.Assemble the Isolators (3) to the Underbracket Assembly (4) using two Locknuts (1) and two Bolts (2), tighten bolts securely.

3.Using four Locknuts (1), four Washers (6), and four Bolts (5) assemble the Underbracket Assembly (4) onto the alternator end of the generator. Tighten all bolts securely inside of rail.

4.Fasten the Axle Support Brackets (7) to the engine end of the generator using four Bolts (5), four Washers

(6)and four Locknuts (1). Tighten all bolts securely.

5.Using two Collars (8), six Washers

(10)and Axle (11) mount both Wheels (9) onto the generator.Make sure the axle is centered with the generator.

6.Attach the Handle Assemblies (14 & 15) to the frame using four Bolts (13), eight Washers (12), and four Locknuts (16), tighten bolts.

GROUNDING INSTRUCTIONS

This product must be grounded. If it should malfunction or breakdown,



Image 4
Contents General Safety Information SpecificationsDescription UnpackingDayton Generator Models 2ZRP8, 2ZRP9 Assembly for Wheels Handles InstallationGrounding Instructions Line Transfer Switch Pre-OperationEngine oil FuelingOperation Battery InstallationHigh Altitude Maintenance Generator MaintenanceElectric Start ShutdownEvaporative Emission Components Idle Control AdjustmentEngine AIR Cleaner Cleaning and Gapping Spark PlugChecking Engine OIL Changing Engine OILShort Term 1-6 months Storing GeneratorLong Term More than 6 months Troubleshooting Chart Generator 2ZRP8, 2ZRP9 For Repair Parts, call Repair Parts 2ZRP8 Repair Parts Illustration for Generator-7500-0GHE Repair Parts 2ZRP9 Repair Parts Illustration for 32-0825 Repair Parts List for 2ZRP8 Generator Repair Parts Illustration for 32-0826 Repair Parts List for 2ZRP9 Generator Repair Parts Illustration for Repair Parts List for Fuel Tank G L I S H Repair Parts Illustration for 2ZRP9 Wire Diagram 2ZRP8, 2ZRP9 Descripción DesembalajeInformación de Seguridad GeneralGenerator Dayton Modelos 2ZRP8, 2ZRP9 Instalación Asamblea Para Ruedas Y AsiderosInstrucciones DE Conexion a Tierra Conmutador de transferencia de lineaAceite DEL Motor Carga DE CombustibleInstalación DE BATERÍA/ Pila Altitud AltaArranque de Retroceso Comienzo El éctricoMantenimiento DEL Generador Componentes de Emisión EvaporadoRegulación de velocidad del control de marcha en vacio MotorInspecciÓn del nivel de aceite Cambio de aceite del motorAlmacenamiento de generador Arrestador DE ChispaMantenimiento 11-SpTabla de Identificación de Problemas 12-SpGarantia Limitada 13-SpServicio permanente 24 horas al día al año 14-SpLista de Partes de Reparación para el/la/los/las 2ZRP8 15-Sp16-Sp Lista de Partes de Reparación para el/la/los/las 2ZRP9 17-Sp18-Sp 19-Sp 20-Sp 21-Sp 22-Sp 23-Sp 24-Sp 25-Sp Notas 26-SpDéballage Consignes Générales de SécuritéVentilation d’air frais suffisante Conserver CES InstructionsModèles 2ZRP8, 2ZRP9 Électrique Montage Pour LES Roues ET LES PoigneesInstructions de mise À la terre Avant opération CarburantRecommendations Générales Type d’essenceInstallation DE LA Batterie MéLANGES D’ESSENCE ET D’éTHERHaute Altitude Démarrage avec lançeur à rappelARRêT Démarrage électriqueEntretien DU Groupe éLECTROGèNE RéGLAGE DE LA Commande DE Ralenti Entretien des pièces d’émission par évaporationMoteur VéRIFICATION DU Niveau D’HUILENettoyage et Réglage de l’écartement des bougies 10-FrPare-étincelles Court terme 1 à 6 moisLong Terme plus de 6 mois 11-FrEntretien 12-FrOuvrir la soupape de carburant 13-FrGarantie Limitée 14-Fr15-Fr Heures par jour 365 jours par an 16-FrListe des pièces détachées pour 2ZRP8 17-Fr18-Fr Illustration des pièces détachées pour GEN-7500-0GHEListe des pièces détachées pour 2ZRP9 19-Fr20-Fr Illustration des pièces détachées pour 32-0825Liste des pièces détachées pour 2ZRP8 Alternateur 21-Fr2ZRP58, 2ZRP9 22-FrListe des pièces détachées pour 2ZRP9 alternateur 23-Fr24-Fr Illustration des pièces détachées pourListe des pièces détachées pour Réservoir de Carburant 25-FrA N Ç a I S Illustration des pièces détachées pour 2ZRP9 Wire Diagram 27-Fr