Emerson U/300/S/12P, U /400/S/12P, U/300/S/6P, U /400/S/6P, 400KVA, 200, 160 user manual Contents

Page 7

 

Contents

 

Chapter 1 General Description

1

1.1

Features

1

1.2

Design Concept

1

 

1.2.1 HIPULSE U Module Design

1

 

1.2.2 Bypass Supplies

2

 

1.2.3 System Control Philosophy

2

 

1.2.4 ECO Mode (For Single UPS Only)

3

 

1.2.5 UPS Power Switch Configuration

4

 

1.2.6 Battery Circuit Breaker

4

 

1.2.7 Battery Temperature Compensation

4

 

1.2.8 System Expansion

4

1.3

Operation Mode

4

Chapter 2 Mechanical Installation

6

2.1

Notes

6

2.2

Environmental Considerations

6

 

2.2.1 UPS Location

6

 

2.2.2 Battery Location

7

2.3

Mechanical Considerations

7

 

2.3.1 System Composition

7

 

2.3.2 Moving The Cabinets

7

 

2.3.3 Clearances

7

 

2.3.4 Fixing Of The Magnetic Components

7

 

2.3.5 Cable Entry

7

2.4

Preliminary Checks

8

2.5

Installation Drawings

8

Chapter 3 Electrical Installation

15

3.1

Power Cabling

15

 

3.1.1 System Configuration

15

 

3.1.2 Cable Rating

15

 

3.1.3 General Notes

16

 

3.1.4 Cable Connections

16

 

3.1.5 Safety Earth

16

 

3.1.6 Protective Devices

16

 

3.1.7 Cabling Procedure

17

3.2

Distance From Floor To Connection Point

19

3.3

Control Cabling

20

 

3.3.1 Monitoring Board Ports

20

Image 7
Contents 31011661 Version V1.0 Revision date April 29Page Page Manual Describes The Following Equipment Safety Precautions Page Contents Page Page Page Hipulse U Module Design FeaturesGeneral Description Design ConceptMains failure Bypass SuppliesSystem Control Philosophy Normal operationECO Mode For Single UPS Only Battery Temperature Compensation Operation ModeUPS Power Switch Configuration Battery Circuit BreakerSource Share mode Auto-restart modeBypass mode Maintenance modeEnvironmental Considerations Mechanical InstallationUPS Location Mechanical Considerations Top view Air Installation DrawingsPreliminary Checks 1905 Front view Air inlet615 556 1061 1210 1251 Top view Air outlet651 761 800 843 Back view Top view Air outlet Front view 1903 Air1641 Side view104 424 155 Top view Air outlet 1685 1626 Cable access Base view415 556 1451 1600 1641 Removable Grille 2 pcs Front正view视图Removable Grille 2 pcsFront view 正视图 Ventilation after being installedAir inlet 进风口 Grille Cable Rating Electrical InstallationPower Cabling System ConfigurationProtective Devices Safety EarthGeneral Notes Cable ConnectionsOutput of the system Cabling ProcedureUPS battery Nm M10 bolts. Ensure Correct Phase RotationRectifier Bypass Earth Auxiliary Terminal blockConnections Distance from floor to connection point Distance From Floor To Connection PointCard Control CablingMonitoring Board Ports Dry contact input portsDry contact output port Description of maintenance bypass cabinet portDescription of dry contact output port Auxiliary DC power output portEPO input port Communication portsCommunication port resource deployment table Battery ControlConnecting Power Cables Connecting Main Cabinet And Side CabinetW41-5 Connecting Signal CablesPort side cabinet Cable No. main cabinet W45ULW36CSA8 Introduction LED IndicatorsDescription of LED indicators Operator Control And Display PanelControl Buttons BuzzerLCD And Menu Keys System information window Detailed Description Of Menu ItemsMenu window and UPS data window Previously set Adjusts the graphic LCD monitor contrast for best viewing中文/English Press the Enter key F4 Use the Shift key F1 and up and down arrow keys F2, F3 toOK or Fault Explanation This setting applies to RS485 communicationCommunication mode RS232 Reserved Callback times Battery capacity test MoreCurrent record window LCD Screen TypesEPO Button Start ScreenPrimary Screen Default ScreenHelp Screen Prompt Window UPS Alarm Message List Ongoing update of monitor firmware Alarm message DescriptionOngoing update of rectifier firmware Ongoing update of inverter firmwareInverter overtemp Can also leads to the alarmUnit over load timeout Is found to be in errorTo this Operating Instructions Power SwitchesService, cannot be used for other purposes Service socket Designed for use in UPSStart-Up Procedure Into ECO Mode Start-Up Procedure Into Normal ModeLED status Test procedure Battery Test Mode ProceduresSystem Test Procedure Battery test type and preconditionsShutdown Procedure Complete UPS And Load Shutdown Maintenance Bypass Procedure And UPS Shut DownLoad equipment is not protected from AC supply aberration UPS Reset Procedure EPO ProcedureLanguage Selection Auto RestartChanging The Current Date And Time Safety BatteryUPS Batteries Battery Population Installation Design ConsiderationsBattery Installation And Maintenance Temperature ConsiderationsConnecting The Battery Battery ProtectionBattery Connection Battery Installation654 1042 BCB Box Optional455 738660 Battery Temperature Sensor OptionalФ13 Knockout Preliminary Checks 1+N System Installation Procedures+N System GeneralPower Cables Cabinet InstallationControl Cables 1+N System Operating InstructionsMaintenance Bypass Procedure And UPS Shut Down Start-Up Procedure Into Normal ModeInsertion Procedure Of One Module In a Parallel System Input rectifier Dual Bus System Installation ProceduresShutdown Procedure Complete UPS And Load Shutdown Bypass suppl y04116100 15m DB25-DB25 DB9-DB904115338 04115339Parallel并机board板 LBS cableParallel board Board LBS cable Parallel cable UPS unit UPS parallel systemConformity And Standard SpecificationsMechanical Characteristics Electrical Characteristics Input RectifierElectrical characteristics DC intermediate circuit Electrical Characteristics DC Intermediate CircuitElectrical characteristics bypass input mains Electrical Characteristics Inverter OutputElectrical Characteristics Bypass Input Mains Electrical characteristics inverter outputElectrical characteristics ECO mode Electrical Characteristics System PerformanceElectrical Characteristics ECO Mode Electrical characteristics system performanceUPS Key Components And Their Lives Service & MaintenanceKey components Life expectancy Lives And Recommended Replacement Time Of Key ComponentsLifves and recommended replacement time of key components Replacing FusesRestraint Appendix 1 Transportation Restraints Removing Procedures螺Screw钉 Amplified view M10螺bolt栓 M12螺bolt栓M10bolts螺栓 Output 输出变压器 transformer 300kVA UPS Transportation Restraints Removing ProceduresOutput 输出变压器 transformer Phase-shifting a AmplifiedA处放大图viewOpen the front door RemoveOpen thebackdoorpanel Phase 移相-shifting 变压 器Installation hole covers 400kVA UPS Transportation Restraints Removing ProceduresBolt 2 pcs Transportation restraint Bolt Phase-shiftingPhase-shifting transformer