Emerson U/300/S/6P, 200 Dual Bus System Installation Procedures, Bypass suppl y, Input rectifier

Page 65

Chapter 7 “1+N” System

55

8.Check that no warning message is displayed in the top right corner of the LCD screen and the status of the LEDs as follows:

Table 7-1

LED status

 

 

 

LED

 

Status

Rectifier LED

 

Steady green

Bypass LED

 

Off

Battery LED

 

Off

Inverter LED

 

Steady green

Load LED

 

Steady green

Alarm LED

 

Off

7.3.5 Shutdown Procedure (Complete UPS And Load Shutdown)

Refer to 5.7 Shutdown Procedure (Complete UPS And Load Shutdown).

7.4 Dual Bus System Installation Procedures

7.4.1 Cabinet Installation

As shown in Figure 7-3, the dual bus system consists of two independent UPS configurations each consisting of one or more UPS modules. Dual bus systems are high availability configurations suitable for loads with multiple input terminals. For single input loads an optional static transfer switch (STS) may be added.

The objective of the dual bus system is to keep the output of two independent UPS systems (or parallel systems) in synchronization using optional load bus synchronization (LBS) cable. One system is designated as the master; the other is designated as the slave. The operating modes covered comprise master and or slave operating inverter or bypass mode.

In installation, place the UPS modules side by side and interconnect as described in the following sections.

Bypass supply

Bypass supply

Input rectifier

Input rectifier

Input rectifier

Input rectifier

 

Parallel

cable

LBS

cable

Parallel

cable

Load

Figure 7-3 Typical dual bus system (using STS and LBS cable)

7.4.2 Protective Devices

Refer to 3.1.6 Protective Devices.

HIPULSE U UPS Single Module And “1+N” (Expandable) 160/200/300/400kVA User Manual

Image 65
Contents 31011661 Version V1.0 Revision date April 29Page Page Manual Describes The Following Equipment Safety Precautions Page Contents Page Page Page General Description FeaturesDesign Concept Hipulse U Module DesignSystem Control Philosophy Bypass SuppliesNormal operation Mains failureECO Mode For Single UPS Only UPS Power Switch Configuration Operation ModeBattery Circuit Breaker Battery Temperature CompensationBypass mode Auto-restart modeMaintenance mode Source Share modeUPS Location Mechanical InstallationEnvironmental Considerations Mechanical Considerations Preliminary Checks Installation Drawings1905 Front view Air inlet Top view Air651 761 800 843 Top view Air outlet615 556 1061 1210 1251 1641 Front view 1903 AirSide view Back view Top view Air outlet415 556 1451 1600 1641 Top view Air outlet 1685 1626 Cable access Base view104 424 155 Removable Front正view视图Grille 2 pcs Removable Grille 2 pcsAir inlet 进风口 Ventilation after being installedFront view 正视图 Grille Power Cabling Electrical InstallationSystem Configuration Cable RatingGeneral Notes Safety EarthCable Connections Protective DevicesUPS battery Cabling ProcedureNm M10 bolts. Ensure Correct Phase Rotation Output of the systemConnections Auxiliary Terminal blockRectifier Bypass Earth Distance from floor to connection point Distance From Floor To Connection PointMonitoring Board Ports Control CablingDry contact input ports CardDry contact output port Description of maintenance bypass cabinet portEPO input port Auxiliary DC power output portCommunication ports Description of dry contact output portCommunication port resource deployment table Battery ControlConnecting Power Cables Connecting Main Cabinet And Side CabinetPort side cabinet Cable No. main cabinet Connecting Signal CablesW45 W41-5ULW36CSA8 Description of LED indicators LED IndicatorsOperator Control And Display Panel IntroductionLCD And Menu Keys BuzzerControl Buttons Menu window and UPS data window Detailed Description Of Menu ItemsSystem information window 中文/English Press the Enter key F4 Adjusts the graphic LCD monitor contrast for best viewingUse the Shift key F1 and up and down arrow keys F2, F3 to Previously setCommunication mode RS232 Reserved Callback times Explanation This setting applies to RS485 communicationBattery capacity test More OK or FaultEPO Button LCD Screen TypesStart Screen Current record windowHelp Screen Default ScreenPrimary Screen Prompt Window UPS Alarm Message List Ongoing update of rectifier firmware Alarm message DescriptionOngoing update of inverter firmware Ongoing update of monitor firmwareUnit over load timeout Can also leads to the alarmIs found to be in error Inverter overtempTo this Operating Instructions Power SwitchesService, cannot be used for other purposes Service socket Designed for use in UPSLED status Start-Up Procedure Into Normal ModeStart-Up Procedure Into ECO Mode System Test Procedure Battery Test Mode ProceduresBattery test type and preconditions Test procedureLoad equipment is not protected from AC supply aberration Maintenance Bypass Procedure And UPS Shut DownShutdown Procedure Complete UPS And Load Shutdown UPS Reset Procedure EPO ProcedureChanging The Current Date And Time Auto RestartLanguage Selection UPS Batteries BatterySafety Battery Installation And Maintenance Installation Design ConsiderationsTemperature Considerations Battery PopulationBattery Connection Battery ProtectionBattery Installation Connecting The Battery455 BCB Box Optional738 654 1042Ф13 Knockout Battery Temperature Sensor Optional660 +N System 1+N System Installation ProceduresGeneral Preliminary ChecksPower Cables Cabinet InstallationControl Cables 1+N System Operating InstructionsInsertion Procedure Of One Module In a Parallel System Start-Up Procedure Into Normal ModeMaintenance Bypass Procedure And UPS Shut Down Shutdown Procedure Complete UPS And Load Shutdown Dual Bus System Installation ProceduresBypass suppl y Input rectifier04115338 DB9-DB904115339 04116100 15m DB25-DB25Parallel board Board LBS cable LBS cableParallel cable UPS unit UPS parallel system Parallel并机board板Mechanical Characteristics SpecificationsElectrical Characteristics Input Rectifier Conformity And StandardElectrical characteristics DC intermediate circuit Electrical Characteristics DC Intermediate CircuitElectrical Characteristics Bypass Input Mains Electrical Characteristics Inverter OutputElectrical characteristics inverter output Electrical characteristics bypass input mainsElectrical Characteristics ECO Mode Electrical Characteristics System PerformanceElectrical characteristics system performance Electrical characteristics ECO modeUPS Key Components And Their Lives Service & MaintenanceLifves and recommended replacement time of key components Lives And Recommended Replacement Time Of Key ComponentsReplacing Fuses Key components Life expectancy螺Screw钉 Amplified view Appendix 1 Transportation Restraints Removing ProceduresM10螺bolt栓 M12螺bolt栓 RestraintOutput 输出变压器 transformer Phase-shifting a 300kVA UPS Transportation Restraints Removing ProceduresAmplifiedA处放大图view M10bolts螺栓 Output 输出变压器 transformerOpen the front door RemoveOpen thebackdoorpanel Phase 移相-shifting 变压 器Installation hole covers 400kVA UPS Transportation Restraints Removing ProceduresBolt 2 pcs Transportation restraint Bolt Phase-shiftingPhase-shifting transformer