The System Status line at the bottom of the UPS Status and Diagnostics screen can display the following Symmetra status conditions:

Runtime Calibration

Waiting to Power Load

Smart Boost

Smart Trim

On-Line

On-Battery

Low Battery

Replace Battery

In Bypass

Sleeping – Delayed Wakeup

Sleeping – Inverter Shutdown

Forcing Graceful Shutdown

Sleeping – Low Battery Shutdown

Overload – Unable

Bad Power Module

Intelligence Module is in- stalled and failed

Redundant Intelligence Module is installed and failed

Bad Battery Module

Load is above kVA alarm threshold

Redundancy has been lost

Redundancy is below alarm threshold

Bypass is not in range (either freq or voltage)

Bypass contactor stuck in bypass position

Bypass Contactor stuck in on-line position

UPS in bypass due to internal fault

UPS in bypass due to over- load

System is in Maintenance Bypass

Input circuit breaker tripped open

System level fan failed

The Redundant Intelligence Module is in control

IIC inter-module communica- tions failed

Turn on requested, override required

UPS will turn on automati- cally when conditions are met

Runtime is below alarm threshold

# of batteries increased

# of batteries decreased

# of power modules increased

# of power modules decreased

Intelligence Module inserted

Intelligence Module removed

Redundant Intelligence Mod- ule inserted

Redundant Intelligence Mod- ule removed

# of External battery Cabinets increased

# of External Battery Cabinets decreased

17

Image 21
Contents Call-UPSII Thank You Contents Problem Resolution Introduction OverviewHardware Requirements Call-UPS II Panel Product DescriptionManagement Port UPS Monitoring Port External VersionPower Port External Version UPS Cable External VersionWith Smart-UPS With Matrix-UPS Status LED Indication Status IndicatorInstallation Installation and SetupHandling Receiving InspectionExternal Version Confirm OperationInitial Logging On Configure Call-UPSPress any key to bring up the Main menu Customize SettingsConnect to Modem SmartSlot Configuration External Configuration UPS Status and Diagnostics OperationLogging On to Call-UPS With Smart-UPS and Matrix-UPS UPS Status Smart-UPS and Matrix-UPS Description Sleeping Inverter Shutdown UPS Status and Diagnostics Symmetra Power Array Description With Symmetra Power ArrayUPS Status and Diagnostics Page RIM Page Command Description UPS ControlUPS Control UPS Control UPS Characteristics Call-UPS II will not allow changes to UPS characteristics Sensitivity of the UPS to power line fluctuation. Set this With Symmetra Power Array UPS Characteristics Symmetra Power Array Setting Description Menu Data/Event LoggingDATA/EVENT Logging Default DescriptionCALL-UPS Call-UPS SettingsCALL-UPS II Settings CALL-UPS II Settings Default Description Site IDspace charactertrouble code Paging SetupPaging Setup Paging Setup Setting Default Description Event Description Paging Setup EventsProbe Measure-UPS InfoMEASURE-UPS Info Troubleshooting Chart Problem ResolutionTroubleshooting Problem Possible Cause SolutionIf Problems Persist Specifications Management Port PinoutPin Function Electrical Product SpecificationsPhysical EnvironmentalAppendix Multiple SmartSlot Installation Device Priority PositionTriple Chassis Symmetra Power Array Daisy ChainsSmart-UPS and Matrix-UPS Page Page Page Limited Warranty Toll free technical support