APC AP9608, AP9208 manual Measure-UPS Info, Probe

Page 40

4.8 Measure-UPS Info

Note: The Measure-UPSInfo Main menu item appears only when Call-UPS II is used in conjunction with a Measure-UPSenvironment monitor.

Type 7, then press ENTER at the main menu to display Measure-UPSstatus, settings, and alarms:

------------------- MEASURE-UPS STATUS ------------------

 

PROBE 1

PROBE 2

TEMP Celsius):

26.67

 

Low Limit: 1-

18.10

5-

High Limit: 2-

23.97

6-

HUMIDITY (%RH):

036.9

 

Low Limit: 3-

040.3

7-

High Limit: 4-

070.0

8-

F/W Rev: 4Gx

------------------ CURRENT ALARMS --------------------

Hi Temp

Lo RH

<ESC>=Main Menu>

The fields on this screen display Measure-UPSreadings for each con- nected probe, settable alarm limits for each probe, and any current alarms. To make changes to the alarm settings, type the number of the menu item (1–8). If you want to change the low humidity limit for the Measure-UPSProbe 1, for example, you can type 3 and press enter. Scroll through the available choices by pressing SPACEBAR. Press ENTER to make the selection and return to the Measure-UPSInfo screen. When you are finished making changes, press ESC to return to the Main menu. The following table describes the status items and lists the choices for the settable alarm limits.

36

Image 40
Contents Call-UPSII Thank You Contents Problem Resolution Overview IntroductionHardware Requirements Product Description Call-UPS II PanelManagement Port UPS Monitoring Port External VersionUPS Cable External Version Power Port External VersionWith Smart-UPS With Matrix-UPS Status Indicator Status LED IndicationInstallation and Setup InstallationHandling Receiving InspectionConfirm Operation External VersionConfigure Call-UPS Initial Logging OnCustomize Settings Press any key to bring up the Main menuConnect to Modem SmartSlot Configuration External Configuration Operation UPS Status and DiagnosticsLogging On to Call-UPS With Smart-UPS and Matrix-UPS UPS Status Smart-UPS and Matrix-UPS Description Sleeping Inverter Shutdown With Symmetra Power Array UPS Status and Diagnostics Symmetra Power Array DescriptionUPS Status and Diagnostics Page RIM Page UPS Control Command DescriptionUPS Control UPS Control UPS Characteristics Call-UPS II will not allow changes to UPS characteristics Sensitivity of the UPS to power line fluctuation. Set this With Symmetra Power Array UPS Characteristics Symmetra Power Array Setting Description Data/Event Logging MenuDefault Description DATA/EVENT LoggingCall-UPS Settings CALL-UPSCALL-UPS II Settings CALL-UPS II Settings Default Description Paging Setup Site IDspace charactertrouble codePaging Setup Paging Setup Setting Default Description Paging Setup Events Event DescriptionMeasure-UPS Info ProbeMEASURE-UPS Info Problem Resolution Troubleshooting ChartTroubleshooting Problem Possible Cause SolutionIf Problems Persist Management Port Pinout SpecificationsPin Function Product Specifications ElectricalPhysical EnvironmentalDevice Priority Position Appendix Multiple SmartSlot InstallationTriple Chassis Daisy Chains Symmetra Power ArraySmart-UPS and Matrix-UPS Page Page Page Limited Warranty Toll free technical support