4.6 Call-UPS Settings

To see or change Call-UPSII settings, go to the main menu and type 5, then press ENTER. You will see the following display.

---------------------

CALL-UPS

SETUP ---------------------

Model

Number: AP9608

HW Rev: A2

Serial

Number: WA718570411

F/W Rev: K

Manuf. Date: 6/27/97

 

---------------------------------------------------------

1-

Set Date: Sep-28 ’97

7-

Ansi Color:

Off

2-

Set Time: 10:38:06

8-

Baud Rate:

9600

3- Set

Password: ********

9-

Answer Ring:

0

4-

Dial Back: OFF

10-Answer Lockout: 0 min

5-Dial Back Str: DT5551212

 

 

 

6-

Location: Physical Location of This UPS

 

---------------------------------------------------------

11- UPS Present: ON

12- Reset Call-UPS to Default Settings ?- Help

<ENTER> Display menu

<ESC> Return to Previous Menu

>

The top section of the Call-UPSSetup menu displays the following Call-UPSII device information which will be needed in case technical support is required:

Model Number — the model number of Call-

UPS II

H/W Rev — the revision of the Call- UPS II hardware

Serial Number — the serial number of this Call- UPS II unit

F/W Rev — the revision number of the Call-

UPS II firmware

Manuf. Date — the date this Call- UPS II was manufactured

The remaining two sections of the Call-UPSSetup menu list changeable settings of Call-UPSII. For a description of these settings, see the table that follows.

29

Image 33
Contents Call-UPSII Thank You Contents Problem Resolution Introduction OverviewHardware Requirements Call-UPS II Panel Product DescriptionManagement Port UPS Monitoring Port External VersionPower Port External Version UPS Cable External VersionWith Smart-UPS With Matrix-UPS Status LED Indication Status IndicatorInstallation Installation and SetupHandling Receiving InspectionExternal Version Confirm OperationInitial Logging On Configure Call-UPSPress any key to bring up the Main menu Customize SettingsConnect to Modem SmartSlot Configuration External Configuration UPS Status and Diagnostics OperationLogging On to Call-UPS With Smart-UPS and Matrix-UPS UPS Status Smart-UPS and Matrix-UPS Description Sleeping Inverter Shutdown UPS Status and Diagnostics Symmetra Power Array Description With Symmetra Power ArrayUPS Status and Diagnostics Page RIM Page Command Description UPS ControlUPS Control UPS Control UPS Characteristics Call-UPS II will not allow changes to UPS characteristics Sensitivity of the UPS to power line fluctuation. Set this With Symmetra Power Array UPS Characteristics Symmetra Power Array Setting Description Menu Data/Event LoggingDATA/EVENT Logging Default DescriptionCALL-UPS Call-UPS SettingsCALL-UPS II Settings CALL-UPS II Settings Default Description Site IDspace charactertrouble code Paging SetupPaging Setup Paging Setup Setting Default Description Event Description Paging Setup EventsProbe Measure-UPS InfoMEASURE-UPS Info Troubleshooting Chart Problem ResolutionTroubleshooting Problem Possible Cause SolutionIf Problems Persist Specifications Management Port PinoutPin Function Electrical Product SpecificationsPhysical EnvironmentalAppendix Multiple SmartSlot Installation Device Priority PositionTriple Chassis Symmetra Power Array Daisy ChainsSmart-UPS and Matrix-UPS Page Page Page Limited Warranty Toll free technical support