APC AP9608, AP9208 manual DATA/EVENT Logging, Default Description

Page 32

DATA/EVENT LOGGING

Item

Default

Description

 

 

 

Power

 

Call-UPS II will log power events, such as utility

ON

line failure and battery exhausted , when enabled.

Events

 

Enter 0 when prompted to disable, 1 to enable.

 

 

 

 

 

 

 

Call-UPS II will log control events, such as UPS

UPS Control

ON

tu rned on and UPS in bypass, when enabled. Enter

 

 

0 to disable, 1 to enable.

 

 

 

 

 

Call-UPS II will log UPS faults, such as UPS is

UPS Faults

ON

overloaded, and internal temperature too high,

 

 

when enabled. Enter 0 to disable, 1 to enable.

 

 

 

User

 

Call-UPS II will log user activity, such as users

ON

logging on and password changes, when enabled.

Activity

 

Enter 0 to disable, 1 to enable.

 

 

 

 

 

 

 

Call-UPS II will log Measure-UPS alarms, e.g.,

Measure-UPS

OFF

high temperature, low temperature, and contact

closure, when enabled. Enter 0 to disable, 1 to

 

 

 

 

enable.

 

 

 

List Event

Display s a list of all reportable events, sorted into event

Groups

groups.

 

 

 

 

View Event

Displays the event log. Call-UPS II pauses af ter each page of

Log

log information.

 

 

 

Reset Event

Clears the event log. Log information is kept in non-volatile

Log

memory, so log items remain even when Call-UPS II is off.

 

 

 

 

Queries the UPS for operating data at preset intervals (see

Log UPS Data

next item) and displays this information on the screen.

Call-UPS II reports date, time, current line voltage, mini-mum

to Screen

line voltage, maximum line voltage, battery voltage, line

 

 

frequency, internal UPS temperature, and UPS load.

 

 

 

Log

Time interval at which Call-UPS II queries the UPS for log

data. The default is 1 minute. Set from 1 to 99 minutes

Interval

between queries, depending on how much data is needed.

 

 

 

 

 

Choose one of two log data output formats. Use text, the

Data Format

default, if the data will be used in word processing programs.

Use the comma delimited format for importing the data into

 

 

spreadsheets or databases.

 

 

 

28

Image 32
Contents Call-UPSII Thank You Contents Problem Resolution Hardware Requirements IntroductionOverview Product Description Call-UPS II PanelManagement Port UPS Monitoring Port External VersionWith Smart-UPS With Matrix-UPS Power Port External VersionUPS Cable External Version Status Indicator Status LED IndicationInstallation and Setup InstallationHandling Receiving InspectionConfirm Operation External VersionConfigure Call-UPS Initial Logging OnCustomize Settings Press any key to bring up the Main menuConnect to Modem SmartSlot Configuration External Configuration Logging On to Call-UPS UPS Status and DiagnosticsOperation With Smart-UPS and Matrix-UPS UPS Status Smart-UPS and Matrix-UPS Description Sleeping Inverter Shutdown With Symmetra Power Array UPS Status and Diagnostics Symmetra Power Array DescriptionUPS Status and Diagnostics Page RIM Page UPS Control Command DescriptionUPS Control UPS Control UPS Characteristics Call-UPS II will not allow changes to UPS characteristics Sensitivity of the UPS to power line fluctuation. Set this With Symmetra Power Array UPS Characteristics Symmetra Power Array Setting Description Data/Event Logging MenuDefault Description DATA/EVENT LoggingCall-UPS Settings CALL-UPSCALL-UPS II Settings CALL-UPS II Settings Default Description Paging Setup Site IDspace charactertrouble codePaging Setup Paging Setup Setting Default Description Paging Setup Events Event DescriptionMeasure-UPS Info ProbeMEASURE-UPS Info Problem Resolution Troubleshooting ChartTroubleshooting Problem Possible Cause SolutionIf Problems Persist Pin Function SpecificationsManagement Port Pinout Product Specifications ElectricalPhysical EnvironmentalTriple Chassis Appendix Multiple SmartSlot InstallationDevice Priority Position Smart-UPS and Matrix-UPS Symmetra Power ArrayDaisy Chains Page Page Page Limited Warranty Toll free technical support