APC AP9208, AP9608 manual

Page 23

module serial number, in addition to raw status readings. Normally you will not need to go to these module status screens unless you need infor- mation for technical support. To return to the Main Frame screen, press ESC.

For External Battery Frame(s) Information, type 2 and press ENTER. The last choice is available only when external battery frames are connected to the Symmetra power array. These external battery frames are num- bered and listed next to the menu item. (See earlier screen capture of the UPS Status and Diagnostics screen.) The message prompts you to enter the battery frame number. Type the number of one of the external battery frames to go to a Battery Frame screen. An example follows.

 

Battery Frame

 

+---------------

+–--------------+

Battery

Battery

OK

OK

+---------------

+---------------

+

Battery

Battery

Failed

No frame IIC

+---------------

+---------------

+

Battery

Battery

OK

OK

+---------------

+---------------

+

Battery

Battery

None

OK

+---------------

+---------------

+

Battery

Battery

None

None

+---------------

+---------------

+

Battery

Battery

None

None

+---------------

+---------------

+

Batteries possible: 12 F/W Rev: A01 Manuf. Date: 06/06/97

Batteries Installed: 07 H/W Rev: G98 S/N: W960123456789 ENTER=Refresh, ESC=Status menu, or enter frame number>

19

Image 23
Contents Call-UPSII Thank You Contents Problem Resolution Hardware Requirements IntroductionOverview UPS Monitoring Port External Version Product DescriptionCall-UPS II Panel Management PortWith Smart-UPS With Matrix-UPS Power Port External VersionUPS Cable External Version Status LED Indication Status IndicatorReceiving Inspection Installation and SetupInstallation HandlingExternal Version Confirm OperationInitial Logging On Configure Call-UPSPress any key to bring up the Main menu Customize SettingsConnect to Modem SmartSlot Configuration External Configuration Logging On to Call-UPS UPS Status and DiagnosticsOperation With Smart-UPS and Matrix-UPS UPS Status Smart-UPS and Matrix-UPS Description Sleeping Inverter Shutdown UPS Status and Diagnostics Symmetra Power Array Description With Symmetra Power ArrayUPS Status and Diagnostics Page RIM Page UPS Control Command DescriptionUPS Control UPS Control UPS Characteristics Call-UPS II will not allow changes to UPS characteristics Sensitivity of the UPS to power line fluctuation. Set this With Symmetra Power Array UPS Characteristics Symmetra Power Array Setting Description Menu Data/Event LoggingDATA/EVENT Logging Default DescriptionCALL-UPS Call-UPS SettingsCALL-UPS II Settings CALL-UPS II Settings Default Description Site IDspace charactertrouble code Paging SetupPaging Setup Paging Setup Setting Default Description Event Description Paging Setup EventsProbe Measure-UPS InfoMEASURE-UPS Info Problem Possible Cause Solution Problem ResolutionTroubleshooting Chart TroubleshootingIf Problems Persist Pin Function SpecificationsManagement Port Pinout Environmental Product SpecificationsElectrical PhysicalTriple Chassis Appendix Multiple SmartSlot InstallationDevice Priority Position Smart-UPS and Matrix-UPS Symmetra Power ArrayDaisy Chains Page Page Page Limited Warranty Toll free technical support