APC AP9608, AP9208 manual Specifications, Management Port Pinout, Pin Function

Page 44

6 Specifications

6.1 Management Port

The management port is a standard 9-pin RS-232serial communications port. The port is configured as data terminal equipment (DTE) with no handshaking, and supports bit rates of 1200, 2400, 9600, and 19,200 bits per second. The data format is 8 data bits, 1 start bit, 1 stop bit, and no parity. The pinout of the management port is listed below.

MANAGEMENT PORT PINOUT

Pin

Function

 

 

1

Unused

 

 

2

Receive data inpute

 

 

3

Transmit data output

 

 

4

RS-232 high

 

 

5

Ground

 

 

6

Unused

 

 

7

Request to send output

 

 

8

Clear to send input

 

 

9

Unused

 

 

40

Image 44
Contents Call-UPSII Thank You Contents Problem Resolution Hardware Requirements IntroductionOverview Product Description Call-UPS II PanelManagement Port UPS Monitoring Port External VersionWith Smart-UPS With Matrix-UPS Power Port External VersionUPS Cable External Version Status Indicator Status LED IndicationInstallation and Setup InstallationHandling Receiving InspectionConfirm Operation External VersionConfigure Call-UPS Initial Logging OnCustomize Settings Press any key to bring up the Main menuConnect to Modem SmartSlot Configuration External Configuration Logging On to Call-UPS UPS Status and DiagnosticsOperation With Smart-UPS and Matrix-UPS UPS Status Smart-UPS and Matrix-UPS Description Sleeping Inverter Shutdown With Symmetra Power Array UPS Status and Diagnostics Symmetra Power Array DescriptionUPS Status and Diagnostics Page RIM Page UPS Control Command DescriptionUPS Control UPS Control UPS Characteristics Call-UPS II will not allow changes to UPS characteristics Sensitivity of the UPS to power line fluctuation. Set this With Symmetra Power Array UPS Characteristics Symmetra Power Array Setting Description Data/Event Logging MenuDefault Description DATA/EVENT LoggingCall-UPS Settings CALL-UPSCALL-UPS II Settings CALL-UPS II Settings Default Description Paging Setup Site IDspace charactertrouble codePaging Setup Paging Setup Setting Default Description Paging Setup Events Event DescriptionMeasure-UPS Info Probe MEASURE-UPS Info Problem Resolution Troubleshooting ChartTroubleshooting Problem Possible Cause SolutionIf Problems Persist Pin Function SpecificationsManagement Port Pinout Product Specifications ElectricalPhysical EnvironmentalTriple Chassis Appendix Multiple SmartSlot InstallationDevice Priority Position Smart-UPS and Matrix-UPS Symmetra Power ArrayDaisy Chains Page Page Page Limited Warranty Toll free technical support