Vixel Model 335 Installation & Configuration Guide | CHAPTER 3 Management | |
|
|
|
|
|
|
| RRDY | The receiving node on this port has sent an R_RDY signal, |
|
| indicating that it is ready for a frame to be transmitted over the |
|
| link. |
|
|
|
| CLS | The port is attempting to begin the process of closing the current |
|
| loop circuit. |
|
|
|
| OPN | The port is attempting to open communications with another |
|
| port on the loop. Note: As is the case with some ordered sets, an |
|
| OPN may not go all the way around the loop, instead stopping |
|
| at its destination. |
|
|
|
| LIP F8 | A |
|
| input, is notifying other ports, and is determining whether the |
|
| loop is still operational. |
|
| Some events that could cause the port to detect loop failure |
|
| follow: |
|
| • A device in the loop has failed. |
|
| • A device in the loop has been powered off. |
|
| • The physical connection between the transmitter and receiver |
|
| is broken. |
|
| • Activating the port bypass circuit does not typically result in a |
|
| loop failure. |
|
|
|
| LIP F7 | A loop port is in the |
|
| to win arbitration and begin initialization, possibly because the |
|
| port was reset or is powering up. Sometimes the port is sending |
|
| this sequence to another, |
|
| being inserted in the loop. |
|
|
|
| LIP | A Loop Initialization Primitive (LIP) sequence has been detected |
|
| and action has been taken. |
|
|
|
| Unknown | The switch can not determine what is being transmitted. |
|
|
|
| InvTxWd | An invalid transmit word has been detected. |
|
|
|
| CRC Err | A Frame CRC error has been detected. |
|
|
|
| A | |
|
|
|