Vixel Model 335 Installation & Configuration Guide | CHAPTER 3 Management | ||
|
|
| |
|
|
| |
| Setting | Description | |
|
|
| |
| Test before | Before allowing a port to insert into a zone, the port is monitored for | |
| insert | proper Loop Port State Machine (LPSM) protocols. (At least one of the | |
|
| devices on the port must be a Loop Initialization Master (LIM) to follow | |
|
| these protocols.) |
|
|
|
| |
| Overlapping | Note: This setting should not be modified unless directed to do so by Vixel | |
| zones | Customer Support. |
|
|
|
| |
| Util period | Note: This setting should not be modified unless directed to do so by Vixel | |
| avg | Customer Support. |
|
|
|
| |
| Util period | Note: This setting should not be modified unless directed to do so by Vixel | |
| stats | Customer Support. |
|
|
|
|
|
| Reset counters | Resets all or specific counters to zero. |
|
|
| Options: |
|
|
| 2: reset all port counters |
|
|
| 3: reset port RX frame counter |
|
|
| 4: reset port conn attempts counter |
|
|
| 5: reset port conn busy counter |
|
|
| 6: reset port CRC errors counter |
|
|
| 7: reset port bad OS errors counter |
|
|
| To reset counters, type 10 at the prompt. Type the number for the | |
|
| desired option. |
|
|
|
|
|
Viewing the Event Log
The event log command enables you to view the event log.
To activate the event log command, type: ev at the prompt.
1:02/27/02 18:38:12.62 [1] agent up
2:02/27/02 18:38:12.72 [160] management active
3:02/27/02 18:38:12.72 [3] switch added, switch ID=14000147
4:02/27/02 18:38:12.81 [270] Daytime server up, ip=38.244.18.9
The switch event log is very good for troubleshooting, as it shows the events on the switch including bypass events, LIP F8, clock delta, etc.
For a complete list of event messages, see EVENT MESSAGES (APPENDIX C) on page 63.
Resetting the Switch
You can reset the switch to implement changes in the CLI.
To reset the switch, type rs at the prompt.
A message stating the switch is resetting appears.
Resetting the Hardware
This feature resets the ASIC in the switch.
To reset the ASIC, type rh at the prompt.
A message stating the control circuitry is resetting appears.
Resetting the Switch to Factory Default Settings
If you want to reset the current switch configuration to the factory default settings, type rc at the prompt.
A message appears asking you to confirm the reset. Type Y at the prompt to proceed with the reset.
51