Vixel Model 335 Installation & Configuration Guide | CHAPTER 4 Technical Reference |
|
|
Small Form-Factor Pluggable (SFP) Issues
Items to check for common
Problem | Recommended Action | |
|
| |
SFP installed in one or | Verify power cord is firmly seated into switch and is connected | |
to a properly earthed receptacle (outlet). | ||
more ports but no LEDs lit | ||
Check the Power LED to ensure switch is turned on. | ||
| ||
|
| |
SFP installed but only | ||
yellow LED is lit | probably faulty and should be replaced. | |
|
| |
| The switch is not receiving a valid Fibre Channel signal from the | |
| end node (HBA or disk array) or is receiving LIP(F8). | |
| 1) Ensure that the device is powered on and operating properly. | |
| 2) Unplug the fiber cable from the node and verify that an | |
| optical signal is present on the cable receiver lead. | |
SFP installed with both | 3) Examine the connectors on the HBA or disk controller for | |
correct and proper connection. If optical power meter is | ||
green and yellow LEDs lit | ||
available, verify the device is transmitting a signal. | ||
| ||
| If there is no signal present, the device may require rebooting, | |
| device drivers may need to be reinstalled, or the HBA or disk | |
| controller hardware may require servicing. | |
| If a signal is present on both the cable lead and the end node, the | |
| HBA or disk controller may require service. | |
|
| |
| The switch is receiving a valid Fibre Channel signal from the end | |
| device (HBA or disk), but no upper level protocols are active. | |
| 1) Verify that the proper HBA device drivers are loaded for the | |
| appropriate operating system and that the host has been | |
| configured to recognize attached disk devices. | |
| 2) Check the Switch Op LED. If the Switch Op LED is on, the | |
| devices have completed initialization. If the Switch Op LED is | |
SFP installed with only | off, the devices were not initialized. Remove all the devices and | |
add one device at a time to isolate the device responsible for the | ||
green LED lit, but devices | ||
failure. | ||
are not communicating | ||
3) Improper initialization could result from a defective or | ||
| ||
| inoperative adapter card or device. Run adapter diagnostics with | |
| a loopback connector to see if the adapter is working properly. | |
| 4) Unplug the fiber cable from the end node and verify that an | |
| optical signal is present on the cable receiver lead. If no signal is | |
| present, the receiver lead of the cable may be bad and the device | |
| may be streaming LIP(F8). Ensure that all cascaded ports are | |
| correctly configured. | |
|
|
Fibre Channel References
The following books give useful information about Fibre Channel.
•Alan F. Benner, Fibre Channel.
•Tom Clark, Designing Storage Area Networks. Addison Wesley Longman, 1999, ISBN
•Jan Dedek, Fibre Channel - The Basics. ANCOT Corporation, 1997. ISBN
•Robert Kembel, Arbitrated Loop. Connectivity Solutions, 1996. ISBN
•Robert Kembel, A Comprehensive Introduction. Connectivity Solutions, 1998. ISBN
56