Vixel 335 manual Understanding the Switch’s LEDs, Power On, System LEDs

Page 9

Vixel Model 335 Installation & Configuration Guide

CHAPTER 2 Installation

 

 

Note: FC-AL compatible nodes must perform initialization procedures upon power-up in order to function properly. It is the responsibility of the Fibre Channel driver software on FC-AL nodes to perform the initialization or re- initialization (depending on its prior state of operation).

4.Make sure the switch and any other connected switches or hubs are powered on.

5.Power on the storage devices (such as JBODs and RAIDs), then power on the hosts. The network initializes.

6.Check all port LEDs. For more information on Port LED status, See “Port LEDs” on page 7.

7.Check the green Switch Op (Switch Operational) LED. If the Switch Op LED is lit, all zones with inserted devices are operational. If the Switch Op LED is blinking in a multiple zone configuration, one or more zones are operational while others are not. If the Switch Op LED is off, no operational zones exist or no devices are attached.

Note: Improper initialization could be the result of a defective or inoperative host bus adapter card or device. Consult the vendor’s documentation for adapter diagnos- tic procedures.

Understanding the Switch’s LEDs

You can check the system and port status through the Light-Emitting Diodes (LEDs) on the switch.

The switch utilizes two sets of LEDs to indicate switch and port status:

1.System LEDs – Six separate LEDs that indicate the status of the switch separate from the Port LEDs.

2.Port LEDs – Two LEDs per switch port that indicate status of that specific port

Figure 2-1.Switch features diagram

Power On

When powering on the switch, all LEDs turn on for two seconds and then off for two seconds except for the Power LED, which remains lit while the switch is powered.

System LEDs

There are six LEDs that indicate the status of the switch, independent of the port LEDs:

Switch

Switch

Switch

Fault

Operational

Speed

Management

Present

Power

Ethernet

Active

Figure 2-2. System LEDs

6

Image 9
Contents InSpeed Model Part Number 00041363-001 Rev. a Table of Contents Introduction FeaturesAbout This Guide OverviewInSpeed Technology Fibre Channel Arbitrated LoopInstallation Unpacking the SwitchInstalling the Switch Performing a Power On Systems Test Using Small Form Factor Pluggable SFP TransceiversSmall Form-Factor Pluggable SFP Installation Small Form-Factor Pluggable SFP RemovalAttaching Devices Setting Up the SwitchUnderstanding the Switch’s LEDs Power OnSystem LEDs Port LEDs System LEDs IndicationSFP Cascading with Non-Overlapping Zones Cascading SwitchesAcceptable Single Cascade in Zones 2-12 Only Using the Web Manager Connecting to the Web ManagerE rv i e w Logging On and Off NavigationConfiguring the Switch Configuration Task Location in Web ManagerResetting the Switch Setting Description System Information SettingsClick Change Settings Network SettingsSwitching Mode Switch SpeedSwitch Identification Blocking ARBTime Settings Downloading the Switch ConfigurationFirmware Information Firmware SettingsEvent Log Messages Click Change Firmware SettingsFC Switch Information FC Switch InformationDetection Indication OS InformationCLS 11.Ordered Set Information Page with Highlighted Zones Port Usage Information13.Received Port Utilization Page with Highlighted Zones Value Description15.Port Information Port Settings16.Port Information Page with Highlighted Zones 18.Cascade Information Mode Description19.Cascade Information Page with Highlighted Zones Switch Policy Description Policy Settings21.Policies Change Settings 22.Overlapping Zones Zone Settings25.Overlapping Zone 1 Information Overlapping ZonesNon-Overlapping Zones 26.Overlapping Zone 1 Information ConfigurationClick Back to Non-overlapping Zone Info to view the changes Management Connecting to the CLI Using the Command Line Interface CLINoz Configuration Task CLI CommandChanging the Switch’s IP Parameters Configuring Switch InformationEnabling or Disabling Dhcp Requests Downloading New Firmware Managing the FirmwareMessage Action Edit Trap Destination Menu Active Value NEW Value Configuring the Trap Destination TableOption Description Viewing Management, Policy, and Threshold Settings Changing the CLI/Web PasswordPolicy Description PoliciesThreshold Information Settings DescriptionAction Description ActionsCommand Description Changing the Switching ModeNumber. You can also change the port policies PLL Displaying PortsEnables you to configure control of the port. Select from Resetting the Hardware Resetting the SwitchResetting the Switch to Factory Default Settings Viewing the Event LogChanging the Switch’s Operating Speed Overlapping Zoning ConfigurationViewing and Understanding Zoning Information Example noz 25,6,7,8 39,10 Non-Overlapping Zoning ConfigurationTechnical Support ReferenceTro ub l e sh oo ti n g Fibre Channel References Small Form-Factor Pluggable SFP IssuesAppendixes Specification s Appendix a SpecificationsVixel Model 335 Operating Conditions Operating ConditionsConsole Commands CommandsGeneral Commands Browse CommandsShow Zone Action CommandsURL Event Meaning Action Severity Message Appendix C Event MessagesAppendix C Event Messages Vixel Model 335 Installation & Configuration Guide Vixel Model 335 Installation & Configuration Guide Cross References Appendix E Glossary Scsi Index Configuring switch informationIndex