CHAPTER 3 Management

 

 

Note: The mc command must be entered prior to issuing one of the submenu commands.

Policies

You can view the current global policy settings and configure the switch to use the policies you select.

Note: Before you type a command for port policies, select the desired port by typing po

#(where # is the desired port number).

An explanation of the available policies follows:

Policy

Description

 

 

Smart insertion

Ensures that data meets the requirements of Fibre Channel

 

Arbitrated Loop (FC-AL) and allows sub-policies to be enabled.

 

 

Bad zone recovery

Reacts to bad zone indications by putting all ports through the

 

normal insertion process and allowing only those ports sending

 

ordered sets to insert.

 

 

No data recovery

The switch will automatically bypass a port if no K characters

 

(Ordered Sets) are detected within a certain timeframe. The

 

switch will try to reinsert the port upon detection of valid K

 

characters.

 

 

LIP F8 recovery

Reacts to LIP(F8)s (indicating non-functional zones) by putting

 

all ports through the normal insertion process and allowing only

 

those ports not sending LIP(F8)s to insert.

 

 

LIP on port bypass

Requires bypassed ports to send LIP(F7)s to other zone

 

members.

 

 

Auto cascade

When this policy is enabled, the switch will automatically

 

configure itself and any other detected Vixel Inspeed devices in a

 

cascade configuration.

 

Note: This policy must be set to enabled if auto cascading on a

 

port is enabled.

 

 

Bypass at max OS err

When this policy is enabled, the switch bypasses a port when

 

that port exceeds the threshold of Ordered Set errors within a

 

certain timeframe.

 

(This policy applies to Zone 1 only.)

 

The default timeframe is 10 seconds (see the Error Count

 

Threshold setting).

 

 

Bypass at max CRC err

When this policy is enabled, the switch bypasses ports that

 

exceed the set threshold of frame CRC errors. Compares the

 

CRC transmitted with a frame to the CRC calculated in the

 

switch.

 

(This policy applies to Zone 1 only.)

 

 

Bypass on clock delta

When this policy is enabled, the switch compares the detected

err

line clock through the frame and the number of fill words

 

inserted or deleted versus the switch’s internal clock. If the

 

derived clock delta is too high, the port is bypassed.

 

 

Bypass on switch stall

When this policy is enabled and switching mode is on, the switch

 

bypasses a stalled port if the connection is not terminated within

 

a certain timeframe (see the Switch Stall Threshold setting).

 

 

Clear conn on sw stall

When this policy is enabled, the switch clears the port

 

connection on a switch stall after a certain timeframe (see the

 

Switch Stall Threshold setting).

 

 

44

Image 47
Contents InSpeed Model Part Number 00041363-001 Rev. a Table of Contents Overview FeaturesIntroduction About This GuideInSpeed Technology Fibre Channel Arbitrated LoopInstalling the Switch InstallationUnpacking the Switch Small Form-Factor Pluggable SFP Removal Using Small Form Factor Pluggable SFP TransceiversPerforming a Power On Systems Test Small Form-Factor Pluggable SFP InstallationAttaching Devices Setting Up the SwitchSystem LEDs Understanding the Switch’s LEDsPower On Port LEDs System LEDs IndicationSFP Cascading with Non-Overlapping Zones Cascading SwitchesAcceptable Single Cascade in Zones 2-12 Only E rv i e w Using the Web ManagerConnecting to the Web Manager Logging On and Off NavigationResetting the Switch Configuring the SwitchConfiguration Task Location in Web Manager Setting Description System Information SettingsClick Change Settings Network SettingsBlocking ARB Switch SpeedSwitching Mode Switch IdentificationTime Settings Downloading the Switch ConfigurationFirmware Information Firmware SettingsEvent Log Messages Click Change Firmware SettingsFC Switch Information FC Switch InformationDetection Indication OS InformationCLS 11.Ordered Set Information Page with Highlighted Zones Port Usage Information13.Received Port Utilization Page with Highlighted Zones Value Description15.Port Information Port Settings16.Port Information Page with Highlighted Zones 18.Cascade Information Mode Description19.Cascade Information Page with Highlighted Zones Switch Policy Description Policy Settings21.Policies Change Settings 22.Overlapping Zones Zone Settings25.Overlapping Zone 1 Information Overlapping ZonesNon-Overlapping Zones 26.Overlapping Zone 1 Information ConfigurationClick Back to Non-overlapping Zone Info to view the changes Management Connecting to the CLI Using the Command Line Interface CLINoz Configuration Task CLI CommandEnabling or Disabling Dhcp Requests Changing the Switch’s IP ParametersConfiguring Switch Information Downloading New Firmware Managing the FirmwareMessage Action Edit Trap Destination Menu Active Value NEW Value Configuring the Trap Destination TableOption Description Viewing Management, Policy, and Threshold Settings Changing the CLI/Web PasswordPolicy Description PoliciesThreshold Information Settings DescriptionAction Description ActionsCommand Description Changing the Switching ModeNumber. You can also change the port policies PLL Displaying PortsEnables you to configure control of the port. Select from Viewing the Event Log Resetting the SwitchResetting the Hardware Resetting the Switch to Factory Default SettingsViewing and Understanding Zoning Information Changing the Switch’s Operating SpeedOverlapping Zoning Configuration Example noz 25,6,7,8 39,10 Non-Overlapping Zoning ConfigurationTechnical Support ReferenceTro ub l e sh oo ti n g Fibre Channel References Small Form-Factor Pluggable SFP IssuesAppendixes Specification s Appendix a SpecificationsVixel Model 335 Operating Conditions Operating ConditionsBrowse Commands CommandsConsole Commands General CommandsShow Zone Action CommandsURL Event Meaning Action Severity Message Appendix C Event MessagesAppendix C Event Messages Vixel Model 335 Installation & Configuration Guide Vixel Model 335 Installation & Configuration Guide Cross References Appendix E Glossary Scsi Index Configuring switch informationIndex