Vixel manual Vixel Model 335 Operating Conditions

Page 62

Vixel Model 335 Installation & Configuration Guide

APPENDIX A Specifications

 

 

Operating Conditions

The switch must be operated in a clean, dry environment with unrestricted airflow. Air flows in through the cosmetic end and out through the business end (sometimes called the transceiver end or “back-of-box”).

To avoid overheating, maintain a minimum clearance of two inches (50.8 millimeters) on each end of the switch (the cosmetic end and the business end). Allow an adequate amount of space on the top and sides of the switch for proper air ventilation. Do not place the switch on heat-generating surfaces. Operating conditions are listed below.

Vixel Model 335 Operating Conditions

Requirement

Value

 

 

Operating Temperature

0°C to 40°C normal operation (ambient air temperature)

 

 

Storage

-40°C to 80°C non-condensing

 

 

Power

50 or 60 Hz / 100 – 250 VAC / 0.6 – 0.4 A

 

 

59

Image 62
Contents InSpeed Model Part Number 00041363-001 Rev. a Table of Contents About This Guide FeaturesIntroduction OverviewFibre Channel Arbitrated Loop InSpeed TechnologyInstalling the Switch InstallationUnpacking the Switch Small Form-Factor Pluggable SFP Installation Using Small Form Factor Pluggable SFP TransceiversPerforming a Power On Systems Test Small Form-Factor Pluggable SFP RemovalSetting Up the Switch Attaching DevicesSystem LEDs Understanding the Switch’s LEDsPower On System LEDs Indication Port LEDsSFP Cascading Switches Cascading with Non-Overlapping ZonesAcceptable Single Cascade in Zones 2-12 Only E rv i e w Using the Web ManagerConnecting to the Web Manager Navigation Logging On and OffResetting the Switch Configuring the SwitchConfiguration Task Location in Web Manager System Information Settings Setting DescriptionNetwork Settings Click Change SettingsSwitch Identification Switch SpeedSwitching Mode Blocking ARBDownloading the Switch Configuration Time SettingsFirmware Settings Firmware InformationClick Change Firmware Settings Event Log MessagesFC Switch Information FC Switch InformationOS Information Detection IndicationCLS Port Usage Information 11.Ordered Set Information Page with Highlighted ZonesValue Description 13.Received Port Utilization Page with Highlighted ZonesPort Settings 15.Port Information16.Port Information Page with Highlighted Zones Mode Description 18.Cascade Information19.Cascade Information Page with Highlighted Zones Policy Settings Switch Policy Description21.Policies Change Settings Zone Settings 22.Overlapping ZonesOverlapping Zones 25.Overlapping Zone 1 Information26.Overlapping Zone 1 Information Configuration Non-Overlapping ZonesClick Back to Non-overlapping Zone Info to view the changes Management Using the Command Line Interface CLI Connecting to the CLIConfiguration Task CLI Command NozEnabling or Disabling Dhcp Requests Changing the Switch’s IP ParametersConfiguring Switch Information Managing the Firmware Downloading New FirmwareMessage Action Configuring the Trap Destination Table Edit Trap Destination Menu Active Value NEW ValueOption Description Changing the CLI/Web Password Viewing Management, Policy, and Threshold SettingsPolicies Policy DescriptionSettings Description Threshold InformationActions Action DescriptionChanging the Switching Mode Command DescriptionNumber. You can also change the port policies Displaying Ports PLLEnables you to configure control of the port. Select from Resetting the Switch to Factory Default Settings Resetting the SwitchResetting the Hardware Viewing the Event LogViewing and Understanding Zoning Information Changing the Switch’s Operating SpeedOverlapping Zoning Configuration Non-Overlapping Zoning Configuration Example noz 25,6,7,8 39,10Reference Technical SupportTro ub l e sh oo ti n g Small Form-Factor Pluggable SFP Issues Fibre Channel ReferencesAppendixes Appendix a Specifications Specification sOperating Conditions Vixel Model 335 Operating ConditionsGeneral Commands CommandsConsole Commands Browse CommandsAction Commands Show ZoneURL Appendix C Event Messages Event Meaning Action Severity MessageAppendix C Event Messages Vixel Model 335 Installation & Configuration Guide Vixel Model 335 Installation & Configuration Guide Cross References Appendix E Glossary Scsi Configuring switch information IndexIndex
Related manuals
Manual 74 pages 62.9 Kb