Vixel 335 manual Configuring the Trap Destination Table

Page 44

Vixel Model 335 Installation & Configuration GuideCHAPTER 3 Management

6. Type fw, then type 1.

The active and alternate firmware versions are displayed.

7.If the “alternate version” is anything other than the firmware you just downloaded, verify that the file is good and repeat the download.

8.If you want to activate the alternate version (the newly downloaded firmware):

a.Type 2 to select the alternate version for execution on the next boot cycle.

b.Type 1 to verify that the following message is displayed under the firmware versions: “Note: ALTERNATE selected for execution on next boot cycle.” (If this message is not displayed, repeat steps a and b to toggle back.)

c.Type 5 to reboot.

The management agent disconnects, reboots, and activates the downloaded firmware. The “Disconnecting and Rebooting” message appears.

The firmware is downloaded.

Configuring the Trap Destination Table

Simple Network Management Protocol (SNMP) uses traps to transmit information to other IP Addressable devices on the network.

To view the current Trap Destination settings and a complete list of commands, type: ct at the prompt. The Trap Destination Table Menu appears:

TRAP DESTINATION TABLE MENU

 

IP ADDRESS

PORT SEVERITY COMMUNITY STATE

Event traps: <none>

 

FcMgmt traps: <none>

 

1.Create new TRAP destination

2.Delete TRAP destination

3.Exit menu

To create a trap destination:

1.Type 1 to create the new TRAP destination.

2.At the resulting IP address prompt, type the address of the workstation you would like the trap sent to.

3.At the resulting UDP Port prompt, type the number of the listening port (usually “162”).

The Edit Trap Destination Menu appears.

EDIT TRAP DESTINATION MENU

 

 

 

ACTIVE VALUE

NEW VALUE

 

IP Address

172.16.52.2

172.16.52.2

 

Port

162

162

1.

Community

'public'

'public'

2.

Severity

Warning

Warning

3.

State

Inactive

Inactive

4.

Mode

Event

Event

5.

Save changes and exit menu

 

6.

Discard changes and exit menu

 

 

 

 

 

41

Image 44
Contents InSpeed Model Part Number 00041363-001 Rev. a Table of Contents Features IntroductionAbout This Guide OverviewFibre Channel Arbitrated Loop InSpeed TechnologyInstalling the Switch InstallationUnpacking the Switch Using Small Form Factor Pluggable SFP Transceivers Performing a Power On Systems TestSmall Form-Factor Pluggable SFP Installation Small Form-Factor Pluggable SFP RemovalSetting Up the Switch Attaching DevicesSystem LEDs Understanding the Switch’s LEDsPower On System LEDs Indication Port LEDsSFP Cascading Switches Cascading with Non-Overlapping ZonesAcceptable Single Cascade in Zones 2-12 Only E rv i e w Using the Web ManagerConnecting to the Web Manager Navigation Logging On and OffResetting the Switch Configuring the SwitchConfiguration Task Location in Web Manager System Information Settings Setting DescriptionNetwork Settings Click Change SettingsSwitch Speed Switching ModeSwitch Identification Blocking ARBDownloading the Switch Configuration Time SettingsFirmware Settings Firmware InformationClick Change Firmware Settings Event Log MessagesFC Switch Information FC Switch InformationOS Information Detection IndicationCLS Port Usage Information 11.Ordered Set Information Page with Highlighted ZonesValue Description 13.Received Port Utilization Page with Highlighted ZonesPort Settings 15.Port Information16.Port Information Page with Highlighted Zones Mode Description 18.Cascade Information19.Cascade Information Page with Highlighted Zones Policy Settings Switch Policy Description21.Policies Change Settings Zone Settings 22.Overlapping ZonesOverlapping Zones 25.Overlapping Zone 1 Information26.Overlapping Zone 1 Information Configuration Non-Overlapping ZonesClick Back to Non-overlapping Zone Info to view the changes Management Using the Command Line Interface CLI Connecting to the CLIConfiguration Task CLI Command NozEnabling or Disabling Dhcp Requests Changing the Switch’s IP ParametersConfiguring Switch Information Managing the Firmware Downloading New FirmwareMessage Action Configuring the Trap Destination Table Edit Trap Destination Menu Active Value NEW ValueOption Description Changing the CLI/Web Password Viewing Management, Policy, and Threshold SettingsPolicies Policy DescriptionSettings Description Threshold InformationActions Action DescriptionChanging the Switching Mode Command DescriptionNumber. You can also change the port policies Displaying Ports PLLEnables you to configure control of the port. Select from Resetting the Switch Resetting the HardwareResetting the Switch to Factory Default Settings Viewing the Event LogViewing and Understanding Zoning Information Changing the Switch’s Operating SpeedOverlapping Zoning Configuration Non-Overlapping Zoning Configuration Example noz 25,6,7,8 39,10Reference Technical SupportTro ub l e sh oo ti n g Small Form-Factor Pluggable SFP Issues Fibre Channel ReferencesAppendixes Appendix a Specifications Specification sOperating Conditions Vixel Model 335 Operating ConditionsCommands Console CommandsGeneral Commands Browse CommandsAction Commands Show ZoneURL Appendix C Event Messages Event Meaning Action Severity MessageAppendix C Event Messages Vixel Model 335 Installation & Configuration Guide Vixel Model 335 Installation & Configuration Guide Cross References Appendix E Glossary Scsi Configuring switch information IndexIndex