APPENDIX C Event Messages
The event messages are listed by reference number. Also included are the event descriptions, recommended actions, reference numbers, and the message’s applicable severity level, which are each defined below:
•
•
•
•
•
•
•
•
•
These severity levels can be used to designate which events trigger trap messages. For Vixel Switches, you can also designate the minimum severity level of events to be logged in the Event Log and at which to illuminate the switch’s Fault LED.
Ref | Event | Meaning | Action | Severity | |
Message | |||||
|
|
|
| ||
|
|
|
|
| |
1 | Agent up | The switch’s management agent | Info | ||
|
| was up. (This message begins |
|
| |
|
| the event log at each session.) |
|
| |
3 | Switch added | The switch was added. | Info | ||
|
|
|
|
| |
5 | Switch reset | The switch was reset. | Info | ||
10 | Switch loopback | ASIC failed its power on self | Contact an authorized | Alert | |
| failure | test (internal test). | service representative. |
| |
|
|
|
|
| |
20 | Smart insertion | The Smart Insertion policy is | Notice | ||
| mode on | enabled. |
|
| |
21 | Smart insertion | The Smart Insertion policy is | Notice | ||
| mode off | disabled. |
|
| |
|
|
|
|
| |
22 | Switch in switching | The switch is running in switch- | Notice | ||
| mode | ing mode. |
|
| |
23 | Switch in normal | The switch is running in normal | Notice | ||
| mode (switching off) | mode (switching is disabled). |
|
| |
|
|
|
|
| |
100 | Fan okay | The state of a switch fan | Info | ||
|
| changed to “okay.” |
|
| |
101 | Fan fault | The state of a switch fan | Replace the fan. | Alert | |
|
| changed to “fault.” |
|
| |
|
|
|
|
| |
110 | Temperature okay | The switch temperature | Info | ||
|
| changed to “okay.” |
|
| |
111 | Temperature warm | The switch temperature | Warning | ||
|
| changed to “warm.” |
|
| |
|
|
|
|
| |
112 | Temperature hot | The switch temperature | Power off the switch and | Alert | |
|
| changed to “hot.” A fan may | contact an authorized |
| |
|
| have failed or the temperature | service representative. |
| |
|
| of the location may be exceed- |
|
| |
|
| ing the switch’s environmental |
|
| |
|
| requirements. |
|
| |
120 | Power okay | The state of the switch power | Info | ||
|
| supply changed to “okay.” |
|
| |
|
|
|
|
| |
121 | Power fault | The state of the switch power | Alert | ||
|
| supply changed to “fault.” |
|
| |
|
|
|
|
|
63