Vixel Model 335 Installation & Configuration Guide | CHAPTER 3 Management | ||
|
|
| |
|
|
| |
| Bypass on CRC Error | When a port exceeds the threshold of frame CRC errors within ten | |
| Threshold* | seconds in Zone 1 and in switching mode, the switch bypasses the | |
|
| port. Note: The threshold can be adjusted. | |
|
|
| |
| Bypass on Clock Delta | When this policy is enabled, the switch compares the detected line | |
| Error | clock through the frame and the number of fill words inserted or | |
|
| deleted versus the switch’s internal clock. If the derived clock delta is | |
|
| too high, the port is bypassed. |
|
|
|
| |
| LIP on Insertion* | When a port inserts into a zone, it issues LIP(F7)s to other zone | |
|
| members. |
|
|
|
| |
| Port Test Before | Before allowing a port to insert into a zone, the port is monitored for | |
| Insertion* | proper Loop Port State Machine (LPSM) protocols. (At least one of | |
|
| the devices on the port must be a Loop Initialization Master (LIM) to | |
|
| follow these protocols.) |
|
|
|
|
|
| * To set this policy, ensure that Smart Insertion is enabled. |
| |
|
|
|
|
To update the switch’s policies:
1.Click Change Settings on the Policy page. The Policies page appears with fields available for modification.
Figure 3-21. Policies (Change Settings) Page
2.You can select whether to enable or disable a specific policy, set thresholds on certain policies, and select specific ports for the LIP on Insertion and Port Test Before Insertion policies.
3.Once you have made your changes, click Update Policies to accept the changes.
4.Click Back to Policy Page to review the new settings.