Vixel Model 335 Installation & Configuration Guide | CHAPTER 3 Management |
|
|
The Zone Information page displays the current zoning configuration, the ports in each zone, the zone state, the init count, and the time duration ("up time") for the zone. The displayed settings are listed below:
Setting | Description |
|
|
Zone number | The zone number on the switch |
|
|
Port number(s) | The port numbers that are assigned to the specified zone. |
|
|
Zone state | The current state of the zone; either "up" or "down". |
|
|
Init Count | The number of times a zone has transitioned from an "down" state to |
| an "up" state. |
|
|
Up Time | The amount of time that the zone has been operational. |
|
|
Overlapping Zones
Overlapping zoning can only be implemented in Zone 1 and the switch must be operating in switching mode. To participate in overlapping zoning, each port must have their cascade mode configured to "auto".
If the switch is operating using
To view the overlapping zoning, click Overlapping. The Overlapping Zone 1
Information page appears.
Figure 3-25. Overlapping Zone 1 Information Page
32