GE LP11U user manual Enclosure

Page 44

g

Digital EnergyLP Series

UPS Type

:

5-11U

6-11U

8-11U

10-11U

ENCLOSURE

 

 

 

 

 

Sheet steel cubicle

:

VSD2

VSD2

VSD2

VSD2

Colour front

:

RAL 9006 (aluminum)

 

 

Colour cabinet

:

RAL 9010 (white)

 

 

Protection

:

IP 20

 

 

 

Dimensions (hxwxd, mm)

:

680x313x730

680x313x730

680x313x730

680x313x730

Dimensions (hxwxd, inch)

:

26.8x12.3x28.7 26.8x12.3x28.7

26.8x12.3x28.7

26.8x12.3x28.7

(height with castors)

 

 

 

 

 

Weight (with batteries, Kg)

:

134 kg

134 kg

175 kg

186 kg

Weight (with batteries, Lbs)

:

295 Lbs

295 Lbs

386 Lbs

410 Lbs

GENERAL DESIGN CRITERIA

 

 

 

 

 

Mechanical

:

IP20

 

 

 

Humidity

:

95% non condensing

 

 

Safety

: UL 1778; 2001, C-UL

 

 

 

 

EN 50091-1-1: 1999; EN 60950 / IEC 950: 2001

 

Surge capability

: 6kV 1.2/50µs; 3kA 8/20µs

 

 

EMC

: FCC part 15, class A; EN 50091-2

 

 

ENVIRONMENT

 

 

 

 

 

Ambient temperature

: -10 to +40°C (14 to 104°F)

 

 

Audible noise at 1 meter

:

40 - 50dB(A),

 

 

 

 

 

the audible noise is load and temperature dependent

 

LX: OPM_LPU_11U_5K0_10K_1US_V030

42

GE DE LP 11U UPS: Installation / User Manual 3.0 (US)

Image 44
Contents Digital Energy LP 11U Page Digital Energy LP Series Important Safety Instructions Interfacing Features General Important Safety InstructionsInstallation Storage BatteriesDescription WarrantyIntroduction Functional Explanation Principles of OperationAutomatic Bypass Switch Installation Package ContentsTransport Unpacking LocationUPS model Tightening torque force Utility voltage UPS model 120V 208V 240VOutput voltage UPS model 120V 208V 240V LP 5/68/10-11U Standard installation procedure LP 5/6-11U Installation procedure 120V input Bypass tap factory setting 208 Volt Available input voltages hardware modificationsInput voltage 208 or 240Vac Bypass tap changed to 240 VoltOutput voltage 208Vac Input voltage 120Vac optional, 5/6kVA onlyAvailable output voltages hardware modifications Output voltage 120Vac split-phase LP 5/6/8/10-11U Output tap changeOutput voltage 120Vac single phase Output voltage 220/230/240VacSetup Screens Input VoltageInput Voltage Change to Output VoltageLP 5/6/8/10-11U Installation of battery pack Installation of parallel operating LP-U UPSs Autorestart OFF Setting Mismatch Autorestart OFF Press EnterMaintenance ECO-modeNo-load shutdown Manual bypassOperation Description of Front and Rear PanelRear panel of the step-up transformer Rear panel Step-up transformerStart-up Selftest ProgressBattery 23C UseInput Line Autonomy Time Left Operating Time 0YEAR 29DAYSTemp TOO High On Line Alarm Press UPStatus and Alarm Menu Inverter OFF Battery Charger no Float Capacitor C1 Capacity LOWBattery Depleted Service Screens Service MenuInput and Output not Synchronized Software Version R2.9 FAN Speed INV.DC +Automatic Bypass Enabled Tstamp Q4Language English Input Voltage Output Voltage Output FrequencyFrequency Range 2% PLL Lock Speed Normal FAN CurveTest Screens Automatic Bypass Enabled Service Warning DisabledQuick Battery Test Start Calibrate BAT Test Activated Deep Battery TestProcedure Other Features Overload protection in bypass modeShutdown Utility startSuperior Battery Management ECOAuto Restart OFF Press Enter Auto restartInterfacing Features RS232 / contact interfaceEmergency shutdown Relay Card optional Snmp Interface optionalOptional Features Extended RuntimePlug-in Cards RPA-Facility Redundant Parallel ArchitecturePDM Power Distribution Module Seismic anchorsMaintenance SafetyRecycling the UPS at the end of service life Cooling fanSelftest Failure Q4 not OK TroubleshootingSelftest Failure Temp TOO High Specifications UPS Type 11U 10-11UAutomatic Bypass Switch Enclosure Dimensions Conduit Box Center of GravityLP 5/6/8/10-11U installation drawings LP 5/6/8/10-11U 208-240V input LP 5/6-11U 120V input