GE LP11U user manual Dimensions Conduit Box, Center of Gravity

Page 45

g

Digital EnergyLP Series

Dimensions Conduit Box

Frontal connection

Connection from below

Center of Gravity

front

H

D

W

UPS cabinet, dimensions hxwxd: 680 x 310 x 710 mm

26.8 x 12.3 x 28.7 inch

Center of gravity, position: H = 275 mm / 10.8 inch W = 155 mm / 6.1 inch D = 300 mm / 11.8 inch

LX: OPM_LPU_11U_5K0_10K_1US_V030

43

GE DE LP 11U UPS: Installation / User Manual 3.0 (US)

Image 45
Contents Digital Energy LP 11U Page Digital Energy LP Series Important Safety Instructions Interfacing Features Important Safety Instructions InstallationGeneral Batteries StorageWarranty IntroductionDescription Principles of Operation Functional ExplanationAutomatic Bypass Switch Package Contents InstallationTransport Unpacking LocationUtility voltage UPS model 120V 208V 240V Output voltage UPS model 120V 208V 240VUPS model Tightening torque force LP 5/68/10-11U Standard installation procedure LP 5/6-11U Installation procedure 120V input Available input voltages hardware modifications Bypass tap factory setting 208 VoltInput voltage 208 or 240Vac Bypass tap changed to 240 VoltInput voltage 120Vac optional, 5/6kVA only Available output voltages hardware modificationsOutput voltage 208Vac LP 5/6/8/10-11U Output tap change Output voltage 120Vac split-phaseOutput voltage 220/230/240Vac Output voltage 120Vac single phaseInput Voltage Setup ScreensInput Voltage Change to Output VoltageLP 5/6/8/10-11U Installation of battery pack Installation of parallel operating LP-U UPSs Autorestart OFF Press Enter Autorestart OFF Setting MismatchECO-mode MaintenanceNo-load shutdown Manual bypassDescription of Front and Rear Panel OperationRear panel Step-up transformer Rear panel of the step-up transformerSelftest Progress Start-upUse Battery 23CInput Line Autonomy Time Left Operating Time 0YEAR 29DAYSOn Line Alarm Press UP Status and Alarm MenuTemp TOO High Battery Charger no Float Capacitor C1 Capacity LOW Battery DepletedInverter OFF Service Menu Service ScreensInput and Output not Synchronized Software Version R2.9 FAN Speed INV.DC +Tstamp Q4 Automatic Bypass EnabledOutput Frequency Language English Input Voltage Output VoltageFrequency Range 2% PLL Lock Speed Normal FAN CurveAutomatic Bypass Enabled Service Warning Disabled Quick Battery Test StartTest Screens Deep Battery Test ProcedureCalibrate BAT Test Activated Overload protection in bypass mode Other FeaturesShutdown Utility startECO Superior Battery ManagementAuto Restart OFF Press Enter Auto restartRS232 / contact interface Interfacing FeaturesEmergency shutdown Relay Card optional Snmp Interface optionalExtended Runtime Optional FeaturesPlug-in Cards RPA-Facility Redundant Parallel ArchitectureSeismic anchors PDM Power Distribution ModuleSafety MaintenanceRecycling the UPS at the end of service life Cooling fanTroubleshooting Selftest Failure Temp TOO HighSelftest Failure Q4 not OK UPS Type 11U 10-11U SpecificationsAutomatic Bypass Switch Enclosure Center of Gravity Dimensions Conduit BoxLP 5/6/8/10-11U installation drawings LP 5/6/8/10-11U 208-240V input LP 5/6-11U 120V input