DS71

 

 

From the configuration menu, select #2,

 

 

 

 

“Serial Port Configuration”, followed by

 

 

 

 

<cr>. The DS unit displays the following

 

 

 

 

table:

 

 

 

 

 

 

 

 

 

 

Module 1 Serial Port Configuration :

 

 

Port

 

Device

Baud

Word

 

Stop

Parity

Xon/

Xoff/

Line

Drive

 

 

Name

Rate

Size

 

Bits

 

Xmit

Recv

DTR

RTS

 

 

 

 

 

 

 

 

 

 

 

 

1

 

EIA-232

9600

8

 

1

None

Off

Off

High

High

Exit/Save

1

Set Parity

5

Set Baud Rate

2

Set Xon/Xoff

6

Set Word Size

3

RTS Line Driver...

7

Set Stop Bits

4

DTR Line Driver...

8

Enter Request :

Select the corresponding number to configure baud rate, word size, stop bits, parity..

NOTE: DTR is unchangeable when configuring the serial port..

For example, to change the baud rate to 115.2K, select #2, “Set Baud Rate,” followed by <cr>.

The DS71 displays the following list of available baud rates:

1 for 300

2 for 600

3 for 1200

4 for 2400

5 for 4800

6 for 9600

7for 19200

8for 38400

9for 57.6K A for 76.8K B for 115.2K Enter Request :

29

Image 37
Contents BayTech Manual Publication #U140A124-01 August DS-RPC Data SWITCH/POWER ControlPage Iii Page Introduction to the DS-RPC DS71-MD2 Technical Support Page Introduction to the DS-RPC Page Feature Description Action Programmable Features of the DS ModulesDS71 or DS71-MD2 Host Module Feature Description Action DS71-MD2 Host Module Programmable Features of the DS Modules con’tModule Feature Description Action DS73TP N EtworkEIA-232 Serial Connection DS-RPC Quick StartOperation Selecting a Device DS-RPC Module Configuration RPC Unpacking InstallationPower Preparing the Installation SitePower UP Sequence Power ON/OFF StateCircuit Breaker RJ-45 Cables and Adapters CablingDS73TP Connection DS71 EIA-232 RJ-45 Pin/Signal Definition DS74 EIA-232 RJ-45 Pin/Signal Definition Modem Connections PIN Connecting to the DS-RPC Detailed Operation ConfigurationEIA-232 Serial ConnectionDS71-MD2 only Detailed Operation and Configuration Operation Device a Device B Device C Device D Selection Menu DrivenAscii Character String$BT2,1cr$BTBcr Binary ModeTerminate Binary ModeMenu PPP DIAL-UP Configuration Status Or this for the DS71-MD2Serial Port ConfigurationDTR RTS 115.2K None Off High Exit/Save..….......1 If you have made necessary changes to Cr. New configuration changes are storedHost device, type Y for yes, followed by Selecting #1 will give the same results asFor For 57.6K a for 76.8K B for 115.2K Enter Request For DTR RTS Host Port Select User programmable. Default Port SelectCode Code is $BTCharacter Guard is disabled Connect Port Default Connect Port ID Echo is disabledID Echo Header is enabled Login SetupHeader Default Password is BTA, disabled. PasswordMenu Auto Connect Port If enabled, the following header and menu appearsSerial connection Port is disabled Escape Character ........… Rings to DisabledAnswer Rings to Answer isDefault Connectivity Timeout is TimeoutConnectivity MinutesEscape Default Escape Character is 43, which isCharacter 2B Hex or a plus sign +Unit Reset Identifies the unit. Default Unit ID is DS71Unit ID Or DS71-MD2Ascii DrivenPort Device Name …..............................3 Selections 1-8 are fully programmable DS73TP Enter password Dial-UP Default Subnet Mask is Default Dial-Up IP Address isSubnet Mask Gateway Default Gateway address isPrimary DNSMenu. Default Secondary DNS address is Default Primary DNS address isSecondary 0.0Default Secondary Nbns address is Default Primary Nbns address isNbns Default Password is BTA Default User Name is user1User Name Module Default Module Name is DS73TPName RPC Operation Accessing Main MenuControlling Receptacles Outlet 1, Outlet 2, Outlet 3, Outlet DS-RPC Config Change PasswordOutlet Outlet 4 Enter Request Is Enabled Enable/DisableConfirmation RPC Technical Support Module DS-RPC Model DS-RPC Serial NumberOutlet OUTLET3 OutletREPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberFCC Requirements for the DS71-MD2 FCC Radio Frequency Interface StatementFCC Radio Frequency Interface Statement Appendix a SpecificationsTable A.1 Base DS71 Host DS71-MD2 DS74 Appendix B Save modem’s configuration in non-volatile memory Rockwell Chip SET Modems Command InterpretationMY Computer Appendix CMake NEW Connection DIAL-UP Networking PropertiesPost Dial Terminal Screen DS71 Mechanical Layout Appendix D DrawingsDS71-MD2 Mechanical Layout DS74 Mechanical Layout DS73 Mechanical Layout Ascii Character Definition Appendix EBreak condition · Rings to Answer · 45, 46 RTS/DTR Line Driver · 29, 31 XON/XOFF ·