Bay Technical Associates DS73 Identifies the unit. Default Unit ID is DS71, Or DS71-MD2

Page 57

DS-RPC OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

__________________________________________________________________________________________

UNIT ID

The unit ID (64 chars. max.) appears in the

 

DS-RPC module Main Menu and uniquely

 

identifies the unit. Default Unit ID is DS71

 

or DS71-MD2.

 

 

Select U, “Unit ID,” from the configuration

 

menu, followed by <cr>. The DS71 or

 

DS71-MD2 module displays the current

 

Unit ID and asks if you want to change:

 

Unit ID is

DS71-MD2

 

Change It? (Y/N Change) :

 

Type “Y“ for yes followed by <cr>. The

DS71 or DS71-MD2 module responds:

Enter Unit ID (64 chars. max.) :

Enter the desired Unit ID, followed by <cr.> The DS71 or DS71-MD2 stores the changes in non-volatile memory and returns to the configuration menu.

I/O MODULES RESET From the main menu, type “RM” to select “I/O Modules Reset,” followed by <cr>. The DS71 or DS71-MD2 module recycles power to all I/O ports on all peripheral modules and responds:

I/O Modules Reset Successfully

Strike any Key to Continue

UNIT RESET

IMPORTANT: Unit reset terminates both internal and external modem connections.

NOTE: You must be connected to a host module (DS71 or DS71- MD2 module) to reset the unit. Resetting the unit does not return user selections to their default settings.

49

Image 57
Contents BayTech Manual Publication #U140A124-01 August DS-RPC Data SWITCH/POWER ControlPage Iii Page Introduction to the DS-RPC DS71-MD2 Technical Support Page Introduction to the DS-RPC Page Programmable Features of the DS Modules Feature Description ActionDS71 or DS71-MD2 Host Module Feature Description Action DS71-MD2 Host Module Programmable Features of the DS Modules con’tModule Feature Description Action DS73TP N EtworkDS-RPC Quick Start EIA-232 Serial ConnectionOperation Selecting a Device DS-RPC Module Configuration RPC Unpacking InstallationPower Preparing the Installation SitePower ON/OFF State Power UP SequenceCircuit Breaker Cabling RJ-45 Cables and AdaptersDS73TP Connection DS71 EIA-232 RJ-45 Pin/Signal Definition DS74 EIA-232 RJ-45 Pin/Signal Definition Modem Connections PIN Connecting to the DS-RPC Detailed Operation ConfigurationEIA-232 Serial ConnectionDS71-MD2 only Detailed Operation and Configuration Operation Device a Device B Device C Device D Selection Menu DrivenAscii Character String$BT2,1cr$BTBcr Binary ModeTerminate Binary ModeMenu PPP DIAL-UPConfiguration Status Or this for the DS71-MD2Serial Port ConfigurationDTR RTS 115.2K None Off High Exit/Save..….......1 If you have made necessary changes to Cr. New configuration changes are storedHost device, type Y for yes, followed by Selecting #1 will give the same results asFor For 57.6K a for 76.8K B for 115.2K Enter Request For DTR RTS Host Port Select User programmable. Default Port SelectCode Code is $BTCharacter Guard is disabled Default Connect Port ID Echo is disabled Connect PortID Echo Login Setup Header is enabledHeader Default Password is BTA, disabled. PasswordMenu Auto Connect Port If enabled, the following header and menu appearsSerial connection Port is disabled Escape Character ........… Rings to DisabledAnswer Rings to Answer isDefault Connectivity Timeout is TimeoutConnectivity MinutesEscape Default Escape Character is 43, which isCharacter 2B Hex or a plus sign +Unit Reset Identifies the unit. Default Unit ID is DS71Unit ID Or DS71-MD2Ascii DrivenPort Device Name …..............................3 Selections 1-8 are fully programmable DS73TP Enter password Dial-UP Default Dial-Up IP Address is Default Subnet Mask isSubnet Mask Gateway Default Gateway address isPrimary DNSMenu. Default Secondary DNS address is Default Primary DNS address isSecondary 0.0Default Primary Nbns address is Default Secondary Nbns address isNbns Default User Name is user1 Default Password is BTAUser Name Default Module Name is DS73TP ModuleName RPC Operation Accessing Main MenuControlling Receptacles Outlet 1, Outlet 2, Outlet 3, Outlet DS-RPC Config Change PasswordOutlet Outlet 4 Enter Request Enable/Disable Is EnabledConfirmation RPC Technical Support Module DS-RPC Model DS-RPC Serial NumberOutlet OUTLET3 OutletREPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberFCC Requirements for the DS71-MD2 FCC Radio Frequency Interface StatementFCC Radio Frequency Interface Statement Specifications Appendix aTable A.1 Base DS71 Host DS71-MD2 DS74 Appendix B Save modem’s configuration in non-volatile memory Rockwell Chip SET Modems Command InterpretationAppendix C MY ComputerMake NEW Connection DIAL-UP Networking PropertiesPost Dial Terminal Screen DS71 Mechanical Layout Appendix D DrawingsDS71-MD2 Mechanical Layout DS74 Mechanical Layout DS73 Mechanical Layout Ascii Character Definition Appendix EBreak condition · Rings to Answer · 45, 46 RTS/DTR Line Driver · 29, 31 XON/XOFF ·