DS-RPC OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

__________________________________________________________________________________________

Set Word Size by selecting #3, “Set Word Size.” The DS71-MD2 displays the following list of available word sizes:

1 For 5

2 For 6

3 For 7

4 For 8

Enter the corresponding number for the desired word size. The DS71 responds with the new configuration status:

Module 1 Serial Port Configuration :

Port

Device

Baud

Word

Stop

Parity

Xon/

Xoff/

Line

Drive

 

Name

Rate

Size

Bits

 

Xmit

Recv

DTR

RTS

 

 

 

 

 

 

 

 

 

 

2

Host MODEM

115.2K

8

1

None

Off

Off

High

High

Exit/Save..….......1

Set Parity...….........5

 

 

 

 

 

Set Baud Rate….2

Set Xon/Xoff….......6

 

 

 

 

 

Set Word Size….3

RTS Line Driver....7

 

 

 

 

 

Set Stop Bits..…..4

DTR Line Driver...8

 

 

 

 

 

Enter Request :

 

 

 

 

 

 

 

 

To permanently save configuration changes, select #1, “Exit/Save,” from the selection menu, followed by <cr>. The DS71-MD2 responds:

Change Host Device to Match NEW Configuration

Before Answering this Request

Save Changes Permanently ? (Y/N) :

IMPORTANT: This message reminds you to change the serial port configuration of the host terminal to match the new configuration changes made to the serial port on the host module. If they do not match, the DS71-MD2 will be unable to interpret the next command, and you will be unable to access any connected unit. If this happens, recycle power and reconfigure the unit. Make any necessary changes to the host device before answering "Save Changes Permanently?"

33

Image 41
Contents BayTech Manual Publication #U140A124-01 August DS-RPC Data SWITCH/POWER ControlPage Iii Page Introduction to the DS-RPC DS71-MD2 Technical Support Page Introduction to the DS-RPC Page DS71 or DS71-MD2 Host Module Programmable Features of the DS ModulesFeature Description Action Feature Description Action DS71-MD2 Host Module Programmable Features of the DS Modules con’tModule Feature Description Action DS73TP N EtworkOperation DS-RPC Quick StartEIA-232 Serial Connection Selecting a Device DS-RPC Module Configuration RPC Unpacking InstallationPower Preparing the Installation SiteCircuit Breaker Power ON/OFF StatePower UP Sequence DS73TP Connection CablingRJ-45 Cables and Adapters DS71 EIA-232 RJ-45 Pin/Signal Definition DS74 EIA-232 RJ-45 Pin/Signal Definition Modem Connections PIN Connecting to the DS-RPC Detailed Operation ConfigurationEIA-232 Serial ConnectionDS71-MD2 only Detailed Operation and Configuration Operation Device a Device B Device C Device D Selection Menu DrivenAscii Character String$BT2,1cr$BTBcr Binary ModeTerminate Binary ModeMenu PPP DIAL-UPConfiguration Status Or this for the DS71-MD2Serial Port ConfigurationDTR RTS 115.2K None Off High Exit/Save..….......1 If you have made necessary changes to Cr. New configuration changes are storedHost device, type Y for yes, followed by Selecting #1 will give the same results asFor For 57.6K a for 76.8K B for 115.2K Enter Request For DTR RTS Host Port Select User programmable. Default Port SelectCode Code is $BTCharacter Guard is disabled ID Echo Default Connect Port ID Echo is disabledConnect Port Header Login SetupHeader is enabled Default Password is BTA, disabled. PasswordMenu Auto Connect Port If enabled, the following header and menu appearsSerial connection Port is disabled Escape Character ........… Rings to DisabledAnswer Rings to Answer isDefault Connectivity Timeout is TimeoutConnectivity MinutesEscape Default Escape Character is 43, which isCharacter 2B Hex or a plus sign +Unit Reset Identifies the unit. Default Unit ID is DS71Unit ID Or DS71-MD2Ascii DrivenPort Device Name …..............................3 Selections 1-8 are fully programmable DS73TP Enter password Dial-UP Subnet Mask Default Dial-Up IP Address isDefault Subnet Mask is Gateway Default Gateway address isPrimary DNSMenu. Default Secondary DNS address is Default Primary DNS address isSecondary 0.0Nbns Default Primary Nbns address isDefault Secondary Nbns address is User Name Default User Name is user1Default Password is BTA Name Default Module Name is DS73TPModule RPC Operation Accessing Main MenuControlling Receptacles Outlet 1, Outlet 2, Outlet 3, Outlet DS-RPC Config Change PasswordOutlet Outlet 4 Enter Request Confirmation Enable/DisableIs Enabled RPC Technical Support Module DS-RPC Model DS-RPC Serial NumberOutlet OUTLET3 OutletREPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberFCC Requirements for the DS71-MD2 FCC Radio Frequency Interface StatementFCC Radio Frequency Interface Statement Table A.1 SpecificationsAppendix a Base DS71 Host DS71-MD2 DS74 Appendix B Save modem’s configuration in non-volatile memory Rockwell Chip SET Modems Command InterpretationMake NEW Connection Appendix CMY Computer DIAL-UP Networking PropertiesPost Dial Terminal Screen DS71 Mechanical Layout Appendix D DrawingsDS71-MD2 Mechanical Layout DS74 Mechanical Layout DS73 Mechanical Layout Ascii Character Definition Appendix EBreak condition · Rings to Answer · 45, 46 RTS/DTR Line Driver · 29, 31 XON/XOFF ·