DS-RPC OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

__________________________________________________________________________________________

 

Enter Primary DNS address in dotted decimal form:

 

Enter the Primary DNS address (Example:

 

200.4.5.53), followed by <cr>. The

 

DS73TP resumes the configuration menu.

 

Default Primary DNS address is 0.0.0.0.

 

If you fail to enter the Primary DNS address

 

in dotted decimal form, the DS73TP

 

responds again:

 

Enter Primary DNS address in dotted decimal form:

 

The DS73TP responds indefinitely with the

 

same request until the Primary DNS address

 

is entered in the correct form.

Secondary

From the configuration menu, select #6,

DNS

“Secondary DNS (Domain Name Server),”

 

followed by <cr>. The DS73TP responds:

 

Enter Secondary DNS address in dotted decimal form:

 

Enter the Secondary DNS address

 

(Example: 200.4.5.54), followed by <cr>.

 

The DS73TP resumes the configuration

 

menu. Default Secondary DNS address is

 

0.0.0.0.

 

If you fail to enter the Secondary DNS

 

address in dotted decimal form, the DS73TP

 

responds again:

Enter Secondary DNS address in dotted decimal form:

58

Image 66
Contents DS-RPC Data SWITCH/POWER Control BayTech Manual Publication #U140A124-01 AugustPage Iii Page Introduction to the DS-RPC DS71-MD2 Technical Support Page Introduction to the DS-RPC Page Programmable Features of the DS Modules Feature Description ActionDS71 or DS71-MD2 Host Module Programmable Features of the DS Modules con’t Feature Description Action DS71-MD2 Host ModuleFeature Description Action DS73TP N Etwork ModuleDS-RPC Quick Start EIA-232 Serial ConnectionOperation Selecting a Device DS-RPC Module Configuration RPC Installation UnpackingPreparing the Installation Site PowerPower ON/OFF State Power UP SequenceCircuit Breaker Cabling RJ-45 Cables and AdaptersDS73TP Connection DS71 EIA-232 RJ-45 Pin/Signal Definition DS74 EIA-232 RJ-45 Pin/Signal Definition Modem Connections PIN EIA-232 Serial Detailed Operation ConfigurationConnecting to the DS-RPC ConnectionDS71-MD2 only Detailed Operation and Configuration Operation Device a Device B Device C Device D Ascii Character Menu DrivenSelection StringTerminate Binary Binary Mode$BT2,1cr$BTBcr ModePPP DIAL-UP MenuConfiguration Or this for the DS71-MD2 StatusConfiguration Serial PortDTR RTS 115.2K None Off High Exit/Save..….......1 Host device, type Y for yes, followed by Cr. New configuration changes are storedIf you have made necessary changes to Selecting #1 will give the same results asFor For 57.6K a for 76.8K B for 115.2K Enter Request For DTR RTS Host Code User programmable. Default Port SelectPort Select Code is $BTCharacter Guard is disabled Default Connect Port ID Echo is disabled Connect PortID Echo Login Setup Header is enabledHeader Password Default Password is BTA, disabled.Menu If enabled, the following header and menu appears Auto Connect PortSerial connection Port is disabled Escape Character ........… Answer DisabledRings to Rings to Answer isConnectivity TimeoutDefault Connectivity Timeout is MinutesCharacter Default Escape Character is 43, which isEscape 2B Hex or a plus sign +Unit ID Identifies the unit. Default Unit ID is DS71Unit Reset Or DS71-MD2Driven AsciiPort Device Name …..............................3 Selections 1-8 are fully programmable DS73TP Enter password Dial-UP Default Dial-Up IP Address is Default Subnet Mask isSubnet Mask Primary Default Gateway address isGateway DNSSecondary Default Primary DNS address isMenu. Default Secondary DNS address is 0.0Default Primary Nbns address is Default Secondary Nbns address isNbns Default User Name is user1 Default Password is BTAUser Name Default Module Name is DS73TP ModuleName Accessing Main Menu RPC OperationControlling Receptacles Outlet 1, Outlet 2, Outlet 3, Outlet Change Password DS-RPC ConfigOutlet Outlet 4 Enter Request Enable/Disable Is EnabledConfirmation RPC Technical Support Outlet DS-RPC Model DS-RPC Serial NumberModule OUTLET3 OutletCall BayTech to get a Return Authorization Number REPACKAGING, Shipping and Returning to the FactoryFCC Radio Frequency Interface Statement FCC Requirements for the DS71-MD2FCC Radio Frequency Interface Statement Specifications Appendix aTable A.1 Base DS71 Host DS71-MD2 DS74 Appendix B Rockwell Chip SET Modems Command Interpretation Save modem’s configuration in non-volatile memoryAppendix C MY ComputerMake NEW Connection Properties DIAL-UP NetworkingPost Dial Terminal Screen Appendix D Drawings DS71 Mechanical LayoutDS71-MD2 Mechanical Layout DS74 Mechanical Layout DS73 Mechanical Layout Appendix E Ascii Character DefinitionBreak condition · Rings to Answer · 45, 46 RTS/DTR Line Driver · 29, 31 XON/XOFF ·