Bay Technical Associates DS73, DS2-RPC, DS4-RPC owner manual If you have made necessary changes to

Page 39

DS-RPC OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

__________________________________________________________________________________________

IMPORTANT: This message reminds you to change the serial port configuration of the host terminal to match the new configuration changes made to the serial port on the host module. If they do not match, the DS71 will be unable to interpret the next command, and you will be unable to access any connected unit. If this happens, recycle power and reconfigure the unit. Make any necessary changes to the host device before answering "Save Changes Permanently?"

 

 

 

If you have made necessary changes to the

 

 

 

host device, type "Y" for yes, followed by

 

 

 

<cr>. New configuration changes are stored

 

 

 

permanently in non-volatile memory.

 

DS71-MD2

 

From the configuration menu, select #2,

 

 

 

“Serial Port Configuration”, followed by

 

 

 

<cr>. The DS unit asks for the Host Device

 

 

 

number.

 

 

 

 

 

 

 

 

Enter Host Device Number (1-2) :

 

 

 

 

 

Selecting #1 will give the same results as the

 

 

 

DS71 in the previous section. Selecting 2

 

 

 

will give the following table:

 

 

Module 1 Serial Port Configuration :

 

 

 

 

 

 

Port

Device

Baud

Word

Stop

Parity

Xon/

Xoff/

Line

Drive

 

Name

Rate

Size

Bits

 

Xmit

Recv

DTR

RTS

 

 

 

 

 

 

 

 

 

 

2

Host MODEM

57.6k

8

1

None

Off

Off

High

High

Exit/Save.............1

Set Parity...............5

 

 

 

 

 

Set Baud Rate.....2

Set Xon/Xoff..........6

 

 

 

 

 

Set Word Size.....3

RTS Line Driver...7

 

 

 

 

 

Set Stop Bits........4

DTR Line Driver...8

 

 

 

 

 

Enter Request :

Select the corresponding number to configure baud rate, word size, stop bits, parity.

31

Image 39
Contents BayTech Manual Publication #U140A124-01 August DS-RPC Data SWITCH/POWER ControlPage Iii Page Introduction to the DS-RPC DS71-MD2 Technical Support Page Introduction to the DS-RPC Page Programmable Features of the DS Modules Feature Description ActionDS71 or DS71-MD2 Host Module Feature Description Action DS71-MD2 Host Module Programmable Features of the DS Modules con’tModule Feature Description Action DS73TP N EtworkDS-RPC Quick Start EIA-232 Serial ConnectionOperation Selecting a Device DS-RPC Module Configuration RPC Unpacking InstallationPower Preparing the Installation SitePower ON/OFF State Power UP SequenceCircuit Breaker Cabling RJ-45 Cables and AdaptersDS73TP Connection DS71 EIA-232 RJ-45 Pin/Signal Definition DS74 EIA-232 RJ-45 Pin/Signal Definition Modem Connections PIN Connection Detailed Operation ConfigurationConnecting to the DS-RPC EIA-232 SerialDS71-MD2 only Detailed Operation and Configuration Operation Device a Device B Device C Device D String Menu DrivenSelection Ascii CharacterMode Binary Mode$BT2,1cr$BTBcr Terminate BinaryMenu PPP DIAL-UPConfiguration Status Or this for the DS71-MD2 Serial Port ConfigurationDTR RTS 115.2K None Off High Exit/Save..….......1 Selecting #1 will give the same results as Cr. New configuration changes are storedIf you have made necessary changes to Host device, type Y for yes, followed byFor For 57.6K a for 76.8K B for 115.2K Enter Request For DTR RTS Host Code is $BT User programmable. Default Port SelectPort Select CodeCharacter Guard is disabled Default Connect Port ID Echo is disabled Connect PortID Echo Login Setup Header is enabledHeader Default Password is BTA, disabled. PasswordMenu Auto Connect Port If enabled, the following header and menu appearsSerial connection Port is disabled Escape Character ........… Rings to Answer is DisabledRings to AnswerMinutes TimeoutDefault Connectivity Timeout is Connectivity2B Hex or a plus sign + Default Escape Character is 43, which isEscape CharacterOr DS71-MD2 Identifies the unit. Default Unit ID is DS71Unit Reset Unit IDAscii DrivenPort Device Name …..............................3 Selections 1-8 are fully programmable DS73TP Enter password Dial-UP Default Dial-Up IP Address is Default Subnet Mask isSubnet Mask DNS Default Gateway address isGateway Primary0.0 Default Primary DNS address isMenu. Default Secondary DNS address is SecondaryDefault Primary Nbns address is Default Secondary Nbns address isNbns Default User Name is user1 Default Password is BTAUser Name Default Module Name is DS73TP ModuleName RPC Operation Accessing Main MenuControlling Receptacles Outlet 1, Outlet 2, Outlet 3, Outlet DS-RPC Config Change PasswordOutlet Outlet 4 Enter Request Enable/Disable Is EnabledConfirmation RPC Technical Support OUTLET3 Outlet DS-RPC Model DS-RPC Serial NumberModule OutletREPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberFCC Requirements for the DS71-MD2 FCC Radio Frequency Interface StatementFCC Radio Frequency Interface Statement Specifications Appendix aTable A.1 Base DS71 Host DS71-MD2 DS74 Appendix B Save modem’s configuration in non-volatile memory Rockwell Chip SET Modems Command InterpretationAppendix C MY ComputerMake NEW Connection DIAL-UP Networking PropertiesPost Dial Terminal Screen DS71 Mechanical Layout Appendix D DrawingsDS71-MD2 Mechanical Layout DS74 Mechanical Layout DS73 Mechanical Layout Ascii Character Definition Appendix EBreak condition · Rings to Answer · 45, 46 RTS/DTR Line Driver · 29, 31 XON/XOFF ·