Bay Technical Associates DS2-RPC, DS4-RPC, DS73 Default Connectivity Timeout is, Minutes

Page 55

DS-RPC OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

__________________________________________________________________________________________

Modem to Modem Xon/Xoff Flow Control is ....Disabled

Enable? (Y/N, CR for no change):

 

Type “Y” for yes followed by <cr> if you

 

want to enable Xon/Xoff. Type “N“ for no

 

followed by <cr> if you want to disable

 

Xon/Xoff. Type <cr> for no change. The

 

DS71-MD2 stores the change in non-volatile

 

memory and returns to the Local Modem

 

Setup menu.

 

Connectivity

Configure the amount of connectivity (5 to

Timeout

255 minutes) before the modem

 

automatically disconnects. Entering a time

 

of 0 disables Connectivity Timeout. The

 

timer starts when the modem answers (DCD

 

high). The modem will disconnect,

 

regardless of activity, when time runs out.

 

Default Connectivity Timeout is 60

 

minutes.

 

 

Select #3, “Connectivity Timeout,” from the

 

Local Modem Setup menu, followed by

 

<cr>. The DS71-MD2 displays the current

 

setting and asks if you want to change:

 

Modem Connectivity Time-out is

60 minutes

 

Change It? (Y/N) :

 

Type “Y“ for yes followed by <cr>. The

DS71-MD2 responds:

Enter Connectivity Time-out (5 to 255, 0 = Disabled)

or press ENTER for no change

:

Enter the number of connectivity minutes (5 to 255) or enter 0 to disable. The DS71- MD2 displays the new setting and asks if you want to change. If there are no further changes, type <cr>. The DS71-MD2 stores changes in non-volatile memory and returns to the Local Modem Setup menu.

47

Image 55
Contents BayTech Manual Publication #U140A124-01 August DS-RPC Data SWITCH/POWER ControlPage Iii Page Introduction to the DS-RPC DS71-MD2 Technical Support Page Introduction to the DS-RPC Page Feature Description Action Programmable Features of the DS ModulesDS71 or DS71-MD2 Host Module Feature Description Action DS71-MD2 Host Module Programmable Features of the DS Modules con’tModule Feature Description Action DS73TP N EtworkEIA-232 Serial Connection DS-RPC Quick StartOperation Selecting a Device DS-RPC Module Configuration RPC Unpacking InstallationPower Preparing the Installation SitePower UP Sequence Power ON/OFF StateCircuit Breaker RJ-45 Cables and Adapters CablingDS73TP Connection DS71 EIA-232 RJ-45 Pin/Signal Definition DS74 EIA-232 RJ-45 Pin/Signal Definition Modem Connections PIN Connection Detailed Operation ConfigurationConnecting to the DS-RPC EIA-232 SerialDS71-MD2 only Detailed Operation and Configuration Operation Device a Device B Device C Device D String Menu DrivenSelection Ascii CharacterMode Binary Mode$BT2,1cr$BTBcr Terminate BinaryMenu PPP DIAL-UPConfiguration Status Or this for the DS71-MD2Serial Port ConfigurationDTR RTS 115.2K None Off High Exit/Save..….......1 Selecting #1 will give the same results as Cr. New configuration changes are storedIf you have made necessary changes to Host device, type Y for yes, followed byFor For 57.6K a for 76.8K B for 115.2K Enter Request For DTR RTS Host Code is $BT User programmable. Default Port SelectPort Select CodeCharacter Guard is disabled Connect Port Default Connect Port ID Echo is disabledID Echo Header is enabled Login SetupHeader Default Password is BTA, disabled. PasswordMenu Auto Connect Port If enabled, the following header and menu appearsSerial connection Port is disabled Escape Character ........… Rings to Answer is DisabledRings to AnswerMinutes TimeoutDefault Connectivity Timeout is Connectivity2B Hex or a plus sign + Default Escape Character is 43, which isEscape CharacterOr DS71-MD2 Identifies the unit. Default Unit ID is DS71Unit Reset Unit IDAscii DrivenPort Device Name …..............................3 Selections 1-8 are fully programmable DS73TP Enter password Dial-UP Default Subnet Mask is Default Dial-Up IP Address isSubnet Mask DNS Default Gateway address isGateway Primary0.0 Default Primary DNS address isMenu. Default Secondary DNS address is SecondaryDefault Secondary Nbns address is Default Primary Nbns address isNbns Default Password is BTA Default User Name is user1User Name Module Default Module Name is DS73TPName RPC Operation Accessing Main MenuControlling Receptacles Outlet 1, Outlet 2, Outlet 3, Outlet DS-RPC Config Change PasswordOutlet Outlet 4 Enter Request Is Enabled Enable/DisableConfirmation RPC Technical Support OUTLET3 Outlet DS-RPC Model DS-RPC Serial NumberModule OutletREPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberFCC Requirements for the DS71-MD2 FCC Radio Frequency Interface StatementFCC Radio Frequency Interface Statement Appendix a SpecificationsTable A.1 Base DS71 Host DS71-MD2 DS74 Appendix B Save modem’s configuration in non-volatile memory Rockwell Chip SET Modems Command InterpretationMY Computer Appendix CMake NEW Connection DIAL-UP Networking PropertiesPost Dial Terminal Screen DS71 Mechanical Layout Appendix D DrawingsDS71-MD2 Mechanical Layout DS74 Mechanical Layout DS73 Mechanical Layout Ascii Character Definition Appendix EBreak condition · Rings to Answer · 45, 46 RTS/DTR Line Driver · 29, 31 XON/XOFF ·