Bay Technical Associates DS73, DS2-RPC, DS4-RPC owner manual Default Password is BTA, disabled

Page 48

DS-RPC OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

__________________________________________________________________________________________

NOTE: This header may appear different depending on type of module installed.

From the selection menu, select #1, “Header,” followed by a carriage return <cr>. The DS71 displays the current header status and asks if you want to enable:

 

Header is

Disabled

 

Enable? (Y/N, CR for no change):

 

Type “Y“ for yes followed by <cr> if you

 

want to enable Header status. Type “N“ for

 

no followed by <cr> if you want to disable

 

Header. Enter <cr> for no change.

Password

To change Password or Enable/Disable

 

Password upon login, select #2, “Password,”

 

from the selection menu, followed by <cr>.

 

Default Password is BTA, disabled. The

 

DS71 or DS71-MD2 module responds:

Change Password.....................1

Enable/Disable......................... 2

Exit.....................................…...X, CR

To change the current password, select #1, “Change Password,” followed by <cr>. The DS71 or DS71-MD2 module responds:

Enter New Password (1 - 8 char., CR to end):

Enter the new password up to 8 ASCII characters followed by <cr>. The DS71 or DS71-MD2 module stores the new password in non-volatile memory and returns to the selection menu.

40

Image 48
Contents DS-RPC Data SWITCH/POWER Control BayTech Manual Publication #U140A124-01 AugustPage Iii Page Introduction to the DS-RPC DS71-MD2 Technical Support Page Introduction to the DS-RPC Page Programmable Features of the DS Modules Feature Description ActionDS71 or DS71-MD2 Host Module Programmable Features of the DS Modules con’t Feature Description Action DS71-MD2 Host ModuleFeature Description Action DS73TP N Etwork ModuleDS-RPC Quick Start EIA-232 Serial ConnectionOperation Selecting a Device DS-RPC Module Configuration RPC Installation UnpackingPreparing the Installation Site PowerPower ON/OFF State Power UP SequenceCircuit Breaker Cabling RJ-45 Cables and AdaptersDS73TP Connection DS71 EIA-232 RJ-45 Pin/Signal Definition DS74 EIA-232 RJ-45 Pin/Signal Definition Modem Connections PIN Detailed Operation Configuration Connecting to the DS-RPCEIA-232 Serial ConnectionDS71-MD2 only Detailed Operation and Configuration Operation Device a Device B Device C Device D Menu Driven SelectionAscii Character StringBinary Mode $BT2,1cr$BTBcrTerminate Binary ModePPP DIAL-UP MenuConfiguration Or this for the DS71-MD2 StatusConfiguration Serial PortDTR RTS 115.2K None Off High Exit/Save..….......1 Cr. New configuration changes are stored If you have made necessary changes toHost device, type Y for yes, followed by Selecting #1 will give the same results asFor For 57.6K a for 76.8K B for 115.2K Enter Request For DTR RTS Host User programmable. Default Port Select Port SelectCode Code is $BTCharacter Guard is disabled Default Connect Port ID Echo is disabled Connect PortID Echo Login Setup Header is enabledHeader Password Default Password is BTA, disabled.Menu If enabled, the following header and menu appears Auto Connect PortSerial connection Port is disabled Escape Character ........… Disabled Rings toAnswer Rings to Answer isTimeout Default Connectivity Timeout isConnectivity MinutesDefault Escape Character is 43, which is EscapeCharacter 2B Hex or a plus sign +Identifies the unit. Default Unit ID is DS71 Unit ResetUnit ID Or DS71-MD2Driven AsciiPort Device Name …..............................3 Selections 1-8 are fully programmable DS73TP Enter password Dial-UP Default Dial-Up IP Address is Default Subnet Mask isSubnet Mask Default Gateway address is GatewayPrimary DNSDefault Primary DNS address is Menu. Default Secondary DNS address isSecondary 0.0Default Primary Nbns address is Default Secondary Nbns address isNbns Default User Name is user1 Default Password is BTAUser Name Default Module Name is DS73TP ModuleName Accessing Main Menu RPC OperationControlling Receptacles Outlet 1, Outlet 2, Outlet 3, Outlet Change Password DS-RPC ConfigOutlet Outlet 4 Enter Request Enable/Disable Is EnabledConfirmation RPC Technical Support DS-RPC Model DS-RPC Serial Number ModuleOutlet OUTLET3 OutletCall BayTech to get a Return Authorization Number REPACKAGING, Shipping and Returning to the FactoryFCC Radio Frequency Interface Statement FCC Requirements for the DS71-MD2FCC Radio Frequency Interface Statement Specifications Appendix aTable A.1 Base DS71 Host DS71-MD2 DS74 Appendix B Rockwell Chip SET Modems Command Interpretation Save modem’s configuration in non-volatile memoryAppendix C MY ComputerMake NEW Connection Properties DIAL-UP NetworkingPost Dial Terminal Screen Appendix D Drawings DS71 Mechanical LayoutDS71-MD2 Mechanical Layout DS74 Mechanical Layout DS73 Mechanical Layout Appendix E Ascii Character DefinitionBreak condition · Rings to Answer · 45, 46 RTS/DTR Line Driver · 29, 31 XON/XOFF ·