DS-RPC OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

__________________________________________________________________________________________

Enter Dial-Up IP address in dotted decimal form:

 

Enter the Dial-Up IP Address (Example:

 

200.4.3.51), followed by <cr>. The

 

DS73TP resumes the configuration menu.

 

Default Dial-Up IP Address is 0.0.0.0.

 

If you fail to enter the Dial-Up IP Address in

 

dotted decimal form, the DS73TP responds

 

again:

 

Enter Dial-Up IP address in dotted decimal form:

 

The DS73TP responds indefinitely with the

 

same request until the Dial-Up IP Address in

 

entered in the correct form.

Subnet Mask

The Subnet Mask is a bit mask that identifies

 

the network portion of the IP address,

 

allowing the DS73TP to determine whether

 

to send a packet directly to the client or to a

 

gate way. The Subnet Mask consist of four

 

bytes, each byte ranging from 0 to 255.

 

From the configuration menu, select #3,

 

“Subnet Mask,” followed by <cr>. The

 

DS73TP responds:

 

Enter Subnet Mask in dotted decimal form:

 

Enter the Subnet Mask (Example:

 

255.255.255.0), followed by <cr>. The

 

DS73TP resumes the configuration menu.

 

Default Subnet Mask is 0.0.0.0.

56

Image 64
Contents DS-RPC Data SWITCH/POWER Control BayTech Manual Publication #U140A124-01 AugustPage Iii Page Introduction to the DS-RPC DS71-MD2 Technical Support Page Introduction to the DS-RPC Page Feature Description Action Programmable Features of the DS ModulesDS71 or DS71-MD2 Host Module Programmable Features of the DS Modules con’t Feature Description Action DS71-MD2 Host ModuleFeature Description Action DS73TP N Etwork ModuleEIA-232 Serial Connection DS-RPC Quick StartOperation Selecting a Device DS-RPC Module Configuration RPC Installation UnpackingPreparing the Installation Site PowerPower UP Sequence Power ON/OFF StateCircuit Breaker RJ-45 Cables and Adapters CablingDS73TP Connection DS71 EIA-232 RJ-45 Pin/Signal Definition DS74 EIA-232 RJ-45 Pin/Signal Definition Modem Connections PIN Detailed Operation Configuration Connecting to the DS-RPCEIA-232 Serial ConnectionDS71-MD2 only Detailed Operation and Configuration Operation Device a Device B Device C Device D Menu Driven SelectionAscii Character StringBinary Mode $BT2,1cr$BTBcrTerminate Binary ModePPP DIAL-UP MenuConfiguration Or this for the DS71-MD2 StatusConfiguration Serial PortDTR RTS 115.2K None Off High Exit/Save..….......1 Cr. New configuration changes are stored If you have made necessary changes toHost device, type Y for yes, followed by Selecting #1 will give the same results asFor For 57.6K a for 76.8K B for 115.2K Enter Request For DTR RTS Host User programmable. Default Port Select Port SelectCode Code is $BTCharacter Guard is disabled Connect Port Default Connect Port ID Echo is disabledID Echo Header is enabled Login SetupHeader Password Default Password is BTA, disabled.Menu If enabled, the following header and menu appears Auto Connect PortSerial connection Port is disabled Escape Character ........… Disabled Rings toAnswer Rings to Answer isTimeout Default Connectivity Timeout isConnectivity MinutesDefault Escape Character is 43, which is EscapeCharacter 2B Hex or a plus sign +Identifies the unit. Default Unit ID is DS71 Unit ResetUnit ID Or DS71-MD2Driven AsciiPort Device Name …..............................3 Selections 1-8 are fully programmable DS73TP Enter password Dial-UP Default Subnet Mask is Default Dial-Up IP Address isSubnet Mask Default Gateway address is GatewayPrimary DNSDefault Primary DNS address is Menu. Default Secondary DNS address isSecondary 0.0Default Secondary Nbns address is Default Primary Nbns address isNbns Default Password is BTA Default User Name is user1User Name Module Default Module Name is DS73TPName Accessing Main Menu RPC OperationControlling Receptacles Outlet 1, Outlet 2, Outlet 3, Outlet Change Password DS-RPC ConfigOutlet Outlet 4 Enter Request Is Enabled Enable/DisableConfirmation RPC Technical Support DS-RPC Model DS-RPC Serial Number ModuleOutlet OUTLET3 OutletCall BayTech to get a Return Authorization Number REPACKAGING, Shipping and Returning to the FactoryFCC Radio Frequency Interface Statement FCC Requirements for the DS71-MD2FCC Radio Frequency Interface Statement Appendix a SpecificationsTable A.1 Base DS71 Host DS71-MD2 DS74 Appendix B Rockwell Chip SET Modems Command Interpretation Save modem’s configuration in non-volatile memoryMY Computer Appendix CMake NEW Connection Properties DIAL-UP NetworkingPost Dial Terminal Screen Appendix D Drawings DS71 Mechanical LayoutDS71-MD2 Mechanical Layout DS74 Mechanical Layout DS73 Mechanical Layout Appendix E Ascii Character DefinitionBreak condition · Rings to Answer · 45, 46 RTS/DTR Line Driver · 29, 31 XON/XOFF ·