5. Menu structure

The touch panel keys or the optional interface can change labeller parameters. The last entered parameters are the actual ones the machine works with. Programming via the interface is described in chapter Serial interface.

There are 2 levels for parameter adjustments. The first one is for parameter selection. With the keys FUNCTION a parameter is selected. By pressing the keys ENTER the second level can be reached. Pressing the keys FUNCTION can change the parameter values. By pressing ENTER you quit the parameter adjustment and the next menu point is shown. For some functions the change of values is effected immediately, for others when leaving the menu point. Details in the menu functions.

There are 4 different menu structures:

Standard menu

This menu is used for normal operation. The most important parameters for the production can be changed here. The adjustments are lost after turning off the machine.

Extended standard menu

This menu offers additional parameters and functions to those in the standard menu. Any adjustments made in the extended menu are stored on quitting the menu and are maintained even if the machine is then turned off.

Product menu

If data banks are stored in the extended menu, the product menu can be activated. In this menu, programmed data banks only can be selected. Changing parameters in this menu is not possible. When storing data in a new data bank, the current adjustments are saved to the new product data bank. You may change data values of a stored data bank by loading the data from the extended standard menu, modifying them and resaving them in a data bank.

Configuration menu

In this menu, you configure the machine according to your applications. Additionally you have access to service test functions. This menu is mainly dedicated to service technicians. All current parameter settings are stored on quitting the configuration menu and are maintained if the machine is then turned off.

Release 4/06

Page 37

Menu structure

Image 39
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Copyright Important NotesOverview ManufacturerGeneral Safety Notes SafetyOperator’s duty of care Concrete security regulations and symbols used Security measures during normal operation Security measures during maintenance and repairsWork on the electrical equipment Work on pneumatic equipmentObserve environmental regulations Mechanics DescriptionMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Installation Preparing the machinePrepare dispensing Define label data Manual adjustment of the Cont parameter Setting Lpit manuallyCapacitive sensor Capacitive label sensorAdjust dispense function Label guideStop position Product data bank Fixed dispensing speedAutomatic dispensing speed Apsf Label position on the productOperation Safety recommendationLeft hand version Right hand version Inserting label materialMounting a new label roll Removing label materialMounting a new label roll on ALS Mounting a new label roll on ALS 330 EuroRewind Adjusting the pressure rollerLead screw adjustment Adjustment of the dispensing edgePrinter adjustment Initializing new label material Adjust pressure rollerMissing label function and web breaks Function Display message Mains switchControl of dispense unit Dispenser Menu selectionDisplay and data input Dispenser active onDisplay Menu function Function data value Dispenser stopped OFF Material initialisation InitLabel position POS Start delaySTAD Stop position StodDispense speed Velo Maintenance Blow on time BlowProduct menu PD0n Release 4/06 Operation Page Extended standard menu Configuration menuMenu structure Standard menuExtended menu ConfigurationStandard menu  Direct ApplicatorStandard menu Initialisation InitDisplay Function Values Start delay Stad Labelling time BlowDispensing speed Velo Display Function Data value Extended standard menuLabel pitch Lpit Label contrastSensor status Sens Label positionPOS Product length PrdlDwell time APT1 Electronic gear ratio adjustment EgraEgra value check Stst Slew speed SlewRestart delay APT3 Blow on time APT2Time constant compensation APT4 Load data bank Load End of air stream signal AstpPrinter dwell time PDT Save parameter in data bank SaveProduct menu Page Possible tests Configuration menuPossible adjustments Calling the configuration menuDisplay Function of the parameter Possible data entry Handling the menuMenu functions Type of applicator Appl Automatic product speed followerAPSFInput and sensor check ICH Output check OCHAdditional functions in the standard menu Number of stop bits Sbit Adjustment resettingFACTInterface baud rate Baud Parity bit PariLabel counter Labc Number of data bits DbitRecycle simulates max labels/min Recy Distance sensor to dispensing edge DistLeave Menu finishing Quit Direction Code Description 25 pol Pol Sub Dispenser connector Signal description Pol DSerial interface Data of the serial interfaceInterface commands Command Description RangeExample Ledg Message in display Output signals Connections and signalsApplicator modes Signals for direct dispenseTiming ASA applicator Control signals for the ASA applicatorAPT2 Signals for the EP applicatorApplicator connector Applicator connectorConnecting NPN left or PNP right inputs Input signalsProduct sensor Example for connecting an NPN sensor DatalogicNPN connection of optional ODC sensor OD Control sensorConnection of a NPN type Apsf sensor Apsf sensorOptional connector for process contro Control signalsInternal I/O connector Rule EMIElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page Message Meaning How to solve Errors and warningsDispenser error messages STO! Power-fail messageInto Eeprom Dispenser warningsALS 330/430 Technical specification Technical InformationDescription Details 330 430 APSF- Sensor Specification Optional function Application specificationCharts Performance chartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Function Factory Application AdjustmentFunction PD05 PD06 PD07 PD08 PD09 Function Factory PD01 PD02 PD03 PD04Index