6.1 Handling the menu

The menu structure is shown in the following table. By means of the key PRIOR you switch to the prior function, and with the key NEXT to the next following function in the menu.

If you press the key ENTER the current parameter value of a function is shown. The current parameter value can be changed with the keys PRIOR FUNCTION or NEXT FUNCTION. Values are stored by pressing the key ENTER.

Display

Function of the parameter

Possible data entry

DTST

Test run without labels

 

 

 

 

P_S_

Product sensor detects at leading or

LEDG, TEDG

 

trailing edge of product

 

 

 

 

MACH

Machine type

230, 720, 330, 430

 

 

 

MDIR

Motor running direction for left or right

<---- --->

 

hand

 

 

 

 

MLAB

Handling of missing label

NONE, WARN, ERR1, ERR2,

 

 

ERR3

 

 

 

APSF

Automatic product speed follower

YES, NO

 

 

 

APPL

Direct dispense mode, or applicators

DIR, ASA, EP, RVEP

 

 

 

I_CH

Test of inputs

 

 

 

 

O_CH

Test of outputs

 

 

 

 

FACT

Reset of all parameters to default values

YES, NO

 

 

 

BAUD

Baudrate of the interface

NONE, 300 to 192%

 

 

 

PARI

Parity bit

NO, 0PRT, ODD, EVEN

 

 

 

SBIT

Number of Stop bits

1 bit, 2 bit

 

 

 

DBIT

Number of data bits

7 bit, 8 bit

 

 

 

RECY

Recycle (simulates max labels/min)

see text

 

 

 

DIST

Distance label sensor to dispensing edge

10 ... 999 mm

 

 

 

LABC

Number of dispensed labels

see text

 

 

 

QUIT

Return to extended standard menu

 

 

 

 

Release 4/06

Page 44

Configuration menu

Image 52
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Important Notes OverviewManufacturer CopyrightSafety General Safety NotesOperator’s duty of care Concrete security regulations and symbols used Security measures during maintenance and repairs Security measures during normal operationWork on pneumatic equipment Work on the electrical equipmentObserve environmental regulations Description MechanicsMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Preparing the machine InstallationPrepare dispensing Define label data Setting Lpit manually Manual adjustment of the Cont parameterCapacitive label sensor Capacitive sensorLabel guide Adjust dispense functionStop position Fixed dispensing speed Automatic dispensing speed ApsfLabel position on the product Product data bankSafety recommendation OperationInserting label material Left hand version Right hand versionRemoving label material Mounting a new label rollMounting a new label roll on ALS 330 Euro Mounting a new label roll on ALSAdjusting the pressure roller RewindAdjustment of the dispensing edge Lead screw adjustmentPrinter adjustment Adjust pressure roller Initializing new label materialFunction Display message Mains switch Control of dispense unitDispenser Menu selection Missing label function and web breaksDispenser active on Display and data inputDisplay Menu function Function data value Material initialisation Init Dispenser stopped OFFLabel position POS Stop position Stod Start delaySTADDispense speed Velo Blow on time Blow MaintenanceProduct menu PD0n Release 4/06 Operation Page Configuration menu Menu structureStandard menu Extended standard menuConfiguration Standard menu  DirectApplicator Extended menuInitialisation Init Standard menuDisplay Function Values Labelling time Blow Start delay StadDispensing speed Velo Extended standard menu Display Function Data valueLabel contrast Label pitch LpitSensor status Sens Product length Prdl Label positionPOSElectronic gear ratio adjustment Egra Egra value check StstSlew speed Slew Dwell time APT1Blow on time APT2 Restart delay APT3Time constant compensation APT4 End of air stream signal Astp Printer dwell time PDTSave parameter in data bank Save Load data bank LoadProduct menu Page Configuration menu Possible adjustmentsCalling the configuration menu Possible testsHandling the menu Display Function of the parameter Possible data entryMenu functions Automatic product speed followerAPSF Type of applicator ApplOutput check OCH Input and sensor check ICHAdditional functions in the standard menu Adjustment resettingFACT Interface baud rate BaudParity bit Pari Number of stop bits SbitNumber of data bits Dbit Recycle simulates max labels/min RecyDistance sensor to dispensing edge Dist Label counter LabcLeave Menu finishing Quit Dispenser connector Signal description Pol D Serial interfaceData of the serial interface Direction Code Description 25 pol Pol SubCommand Description Range Interface commandsExample Ledg Message in display Connections and signals Output signalsSignals for direct dispense Applicator modesControl signals for the ASA applicator Timing ASA applicatorSignals for the EP applicator APT2Applicator connector Applicator connectorInput signals Connecting NPN left or PNP right inputsExample for connecting an NPN sensor Datalogic Product sensorOD Control sensor NPN connection of optional ODC sensorApsf sensor Connection of a NPN type Apsf sensorControl signals Optional connector for process controInternal I/O connector EMI RuleElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page Errors and warnings Dispenser error messagesSTO! Power-fail message Message Meaning How to solveInto Dispenser warnings EepromALS 330/430 Technical Information Technical specificationDescription Details 330 430 Application specification APSF- Sensor Specification Optional functionPerformance charts ChartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Adjustment Function Factory ApplicationFunction Factory PD01 PD02 PD03 PD04 Function PD05 PD06 PD07 PD08 PD09Index