Avery ALS 330/430 manual Start delay Stad, Labelling time Blow, Dispensing speed Velo

Page 42

Operators Manual

ALS 330/430

Label position ____________________________________________________POS

Function: The start position POS defines when the labelling should take place, after the product has passed the product sensor. Changing the value for POS changes the applied label position on the product.

Only available if no applicator is used. Range: up to 999.9 mm in steps of 0.1 mm.

Start delay ______________________________________________________STAD

Function: Delay time for the dispensing after the product has passed the product sensor. This value influences the position of the label on the product.

Only available if an applicator is used. Range: 1 to 9999 ms

Stop position ___________________________________________________ STOD

Function: Stop position of the label once the label edge has reached the dispensing edge. The STOD value defines the actual stop position of the label in steps of 0.1 mm.

With this adjustment the label can be made to stop directly at the dispensing edge. To make the label stop after the dispensing edge the value of STOD should be adjusted accordingly.

ySelect the parameter STOD by pressing the keys FUNCTION.

yBy pressing the key ENTER the data input is activated. Range: 0.0 .... 200.0 (mm).

Labelling time___________________________________________________ BLOW

Function: The labelling time defines how long the applicator should blow the label onto the product.

Only available if an applicator is used. BLOW is identical with APT2 Range: 1 to 9999 ms

Dispensing speed ________________________________________________VELO

Function: This parameter defines the speed for the label material. Only available if no applicator

is used: With an automatic product speed sensor the actual speed is shown.

Range : 0.2 ... 30.0 m/min

Release 4/06

Page 40

Menu structure

Image 42
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Manufacturer Important NotesOverview CopyrightSafety General Safety NotesOperator’s duty of care Concrete security regulations and symbols used Security measures during maintenance and repairs Security measures during normal operationWork on the electrical equipment Work on pneumatic equipmentObserve environmental regulations Description MechanicsMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Installation Preparing the machinePrepare dispensing Define label data Setting Lpit manually Manual adjustment of the Cont parameterCapacitive label sensor Capacitive sensorAdjust dispense function Label guideStop position Label position on the product Fixed dispensing speedAutomatic dispensing speed Apsf Product data bankSafety recommendation OperationInserting label material Left hand version Right hand versionRemoving label material Mounting a new label rollMounting a new label roll on ALS 330 Euro Mounting a new label roll on ALSAdjusting the pressure roller RewindLead screw adjustment Adjustment of the dispensing edgePrinter adjustment Adjust pressure roller Initializing new label materialDispenser Menu selection Function Display message Mains switchControl of dispense unit Missing label function and web breaksDisplay and data input Dispenser active onDisplay Menu function Function data value Dispenser stopped OFF Material initialisation InitLabel position POS Start delaySTAD Stop position StodDispense speed Velo Maintenance Blow on time BlowProduct menu PD0n Release 4/06 Operation Page Standard menu Configuration menuMenu structure Extended standard menuApplicator ConfigurationStandard menu  Direct Extended menuStandard menu Initialisation InitDisplay Function Values Start delay Stad Labelling time BlowDispensing speed Velo Extended standard menu Display Function Data valueLabel pitch Lpit Label contrastSensor status Sens Product length Prdl Label positionPOSSlew speed Slew Electronic gear ratio adjustment EgraEgra value check Stst Dwell time APT1Restart delay APT3 Blow on time APT2Time constant compensation APT4 Save parameter in data bank Save End of air stream signal AstpPrinter dwell time PDT Load data bank LoadProduct menu Page Calling the configuration menu Configuration menuPossible adjustments Possible testsHandling the menu Display Function of the parameter Possible data entryMenu functions Automatic product speed followerAPSF Type of applicator ApplInput and sensor check ICH Output check OCHAdditional functions in the standard menu Parity bit Pari Adjustment resettingFACTInterface baud rate Baud Number of stop bits SbitDistance sensor to dispensing edge Dist Number of data bits DbitRecycle simulates max labels/min Recy Label counter LabcLeave Menu finishing Quit Data of the serial interface Dispenser connector Signal description Pol DSerial interface Direction Code Description 25 pol Pol SubInterface commands Command Description RangeExample Ledg Message in display Connections and signals Output signalsSignals for direct dispense Applicator modesControl signals for the ASA applicator Timing ASA applicatorSignals for the EP applicator APT2Applicator connector Applicator connectorInput signals Connecting NPN left or PNP right inputsExample for connecting an NPN sensor Datalogic Product sensorOD Control sensor NPN connection of optional ODC sensorApsf sensor Connection of a NPN type Apsf sensorControl signals Optional connector for process controInternal I/O connector EMI RuleElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page STO! Power-fail message Errors and warningsDispenser error messages Message Meaning How to solveInto Dispenser warnings EepromALS 330/430 Technical specification Technical InformationDescription Details 330 430 Application specification APSF- Sensor Specification Optional functionPerformance charts ChartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Adjustment Function Factory ApplicationFunction Factory PD01 PD02 PD03 PD04 Function PD05 PD06 PD07 PD08 PD09Index