Avery ALS 330/430 manual Standard menu, Initialisation Init, Display Function Values

Page 41

Operators Manual

ALS 330/430

5.1 Standard menu

Usually this menu is used for labelling. All important parameters can be changed while the machine is running. After turning power on, the standard menu is active, unless the product menu was on before the machine was switched off.

If the product menu is active and you want to use the standard menu, switch off the machine again. Press the key NEXT FUNCTION while switching on the machine and the standard menu is active. In the standard menu you have access to all important parameters for labelling. The number of parameter and its kind depends on how the configuration has been made. Change of parameters is active immediately. Changed values are lost when turning off power. If values need to be stored, the extended standard menu has to be used. All available commands are listed down below.

Display

Function

Values

ON

Normal operation

 

 

 

 

 

 

OFF

Stop labelling operation

 

 

 

 

 

INIT

Initialisation of label sensor and label

After status of E__0 and E__1

 

pitch detection

only

 

 

 

POS

Position of label on the product

Up to 999.9 mm

 

 

 

 

STOD

Stop position of label at the dispensing

0,0

..... 200,0 mm

 

edge

 

 

 

 

 

 

VELO

Labelling speed

0.2

... 30.0 m/min

 

 

 

STAD

Delay time for labelling with applicator

1 ... 9999 ms

 

 

 

 

BLOW

apply time

0.1

... 999.9 ms

 

 

 

 

Initialisation ______________________________________________________ INIT

The function INIT is available only, if required for a new initialisation. Which is the case under the following circumstances:

a)Status error message E__0, the feed key was pressed with pressure roller open

b)Status E__1, while moving the label web no labels have been recognised over a web length of 4 labels.

c)During power on the FEED key was held depressed.

d)CONT or LPIT were changed to automatic mode.

Note: A new initialisation after an E__0 or E__1 message is not absolutely necessary if you sure that the label parameter are all right. Then leave the INIT display with the NEXT key and press only the key FEED to reposition the label at the dispensing edge.

Release 4/06

Page 39

Menu structure

Image 41
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Overview Important NotesManufacturer CopyrightGeneral Safety Notes SafetyOperator’s duty of care Concrete security regulations and symbols used Security measures during normal operation Security measures during maintenance and repairsObserve environmental regulations Work on the electrical equipmentWork on pneumatic equipment Mechanics DescriptionMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Prepare dispensing InstallationPreparing the machine Define label data Manual adjustment of the Cont parameter Setting Lpit manuallyCapacitive sensor Capacitive label sensorStop position Adjust dispense functionLabel guide Automatic dispensing speed Apsf Fixed dispensing speedLabel position on the product Product data bankOperation Safety recommendationLeft hand version Right hand version Inserting label materialMounting a new label roll Removing label materialMounting a new label roll on ALS Mounting a new label roll on ALS 330 EuroRewind Adjusting the pressure rollerPrinter adjustment Lead screw adjustmentAdjustment of the dispensing edge Initializing new label material Adjust pressure rollerControl of dispense unit Function Display message Mains switchDispenser Menu selection Missing label function and web breaksDisplay Menu function Function data value Display and data inputDispenser active on Label position POS Dispenser stopped OFFMaterial initialisation Init Dispense speed Velo Start delaySTADStop position Stod Product menu PD0n MaintenanceBlow on time Blow Release 4/06 Operation Page Menu structure Configuration menuStandard menu Extended standard menuStandard menu  Direct ConfigurationApplicator Extended menuDisplay Function Values Standard menuInitialisation Init Dispensing speed Velo Start delay StadLabelling time Blow Display Function Data value Extended standard menuSensor status Sens Label pitch LpitLabel contrast Label positionPOS Product length PrdlEgra value check Stst Electronic gear ratio adjustment EgraSlew speed Slew Dwell time APT1Time constant compensation APT4 Restart delay APT3Blow on time APT2 Printer dwell time PDT End of air stream signal AstpSave parameter in data bank Save Load data bank LoadProduct menu Page Possible adjustments Configuration menuCalling the configuration menu Possible testsDisplay Function of the parameter Possible data entry Handling the menuMenu functions Type of applicator Appl Automatic product speed followerAPSFAdditional functions in the standard menu Input and sensor check ICHOutput check OCH Interface baud rate Baud Adjustment resettingFACTParity bit Pari Number of stop bits SbitRecycle simulates max labels/min Recy Number of data bits DbitDistance sensor to dispensing edge Dist Label counter LabcLeave Menu finishing Quit Serial interface Dispenser connector Signal description Pol DData of the serial interface Direction Code Description 25 pol Pol SubExample Interface commandsCommand Description Range Ledg Message in display Output signals Connections and signalsApplicator modes Signals for direct dispenseTiming ASA applicator Control signals for the ASA applicatorAPT2 Signals for the EP applicatorApplicator connector Applicator connectorConnecting NPN left or PNP right inputs Input signalsProduct sensor Example for connecting an NPN sensor DatalogicNPN connection of optional ODC sensor OD Control sensorConnection of a NPN type Apsf sensor Apsf sensorOptional connector for process contro Control signalsInternal I/O connector Rule EMIElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page Dispenser error messages Errors and warningsSTO! Power-fail message Message Meaning How to solveInto Eeprom Dispenser warningsALS 330/430 Description Details 330 430 Technical specificationTechnical Information APSF- Sensor Specification Optional function Application specificationCharts Performance chartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Function Factory Application AdjustmentFunction PD05 PD06 PD07 PD08 PD09 Function Factory PD01 PD02 PD03 PD04Index