Avery ALS 330/430 manual Adjustment resettingFACT, Interface baud rate Baud, Parity bit Pari

Page 56

Operators Manual

ALS 330/430

7 = terminal 31 = READY

8 = terminal 32 = ODC_OUT / HORI_CYL

Adjustment resetting______________________________________________FACT

This menu point sets all parameters back to the factory values. All parameters will be reset, so please note all your adjustments before. When you call this function the display shows 'NO`. After you have left by pressing the key ENTER there is no change.

When you change with the key NEXT to YES and press ENTER all parameters are reset to default values.

Note: This function also clears all product banks.

Interface baud rate_______________________________________________ BAUD

With this function the baud rate of the interface will be adjusted. This is an option of the machine. If you do not have this option, the parameter has to be set to 'NONE` to protect the interface and to avoid errors. The following baud rates are adjustable: 150, 300, 600, 2400, 4800, 9600 and 19200 baud. When calling the function FACT this parameter will be set to `NONE`. When the machine is delivered with the interface the baud rate is set to 9600. Select your baud rate by pressing the key NEXT or PRIOR . With the key ENTER the adjustment is stored.

Factory adjustment: NONE

Parity bit ________________________________________________________ PARI

The function is only visible if a baudrate is selected. The parity bit is necessary to check the data transfer. In case of wrong data transfer an error message will be given. The adjustment of both machines has to be identical. Usually the transfer is made without parity bit.

Possible adjustments:

'NO`:

Not sending or receiving a parity bit

`EVEN`:

produce a parity bit so that an equal number of `1` signals is created

`ODD`:

produce a parity bit so that an odd number of '1' signals is created.

`0PRT`:

The parity bit is always 0

By pressing the key NEXT or PRIOR the adjustment is selected and by pressing the key ENTER the function is finished.

Factory adjustment: NO

Number of stop bits_______________________________________________ SBIT

The function is only visible if a baudrate is selected. This parameter defines the number of stop bits. By pressing the key function you can select between `1BIT` or `2BIT`. By pressing the key ENTER this function will be left.

Factory adjustment: 1BIT

Release 4/06

Page 48

Configuration menu

Image 56
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Important Notes OverviewManufacturer CopyrightSafety General Safety NotesOperator’s duty of care Concrete security regulations and symbols used Security measures during maintenance and repairs Security measures during normal operationObserve environmental regulations Work on the electrical equipmentWork on pneumatic equipment Description MechanicsMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Prepare dispensing InstallationPreparing the machine Define label data Setting Lpit manually Manual adjustment of the Cont parameterCapacitive label sensor Capacitive sensorStop position Adjust dispense functionLabel guide Fixed dispensing speed Automatic dispensing speed ApsfLabel position on the product Product data bankSafety recommendation OperationInserting label material Left hand version Right hand versionRemoving label material Mounting a new label rollMounting a new label roll on ALS 330 Euro Mounting a new label roll on ALSAdjusting the pressure roller RewindPrinter adjustment Lead screw adjustmentAdjustment of the dispensing edge Adjust pressure roller Initializing new label materialFunction Display message Mains switch Control of dispense unitDispenser Menu selection Missing label function and web breaksDisplay Menu function Function data value Display and data inputDispenser active on Label position POS Dispenser stopped OFFMaterial initialisation Init Dispense speed Velo Start delaySTADStop position Stod Product menu PD0n MaintenanceBlow on time Blow Release 4/06 Operation Page Configuration menu Menu structureStandard menu Extended standard menuConfiguration Standard menu  DirectApplicator Extended menuDisplay Function Values Standard menuInitialisation Init Dispensing speed Velo Start delay StadLabelling time Blow Extended standard menu Display Function Data valueSensor status Sens Label pitch LpitLabel contrast Product length Prdl Label positionPOSElectronic gear ratio adjustment Egra Egra value check StstSlew speed Slew Dwell time APT1Time constant compensation APT4 Restart delay APT3Blow on time APT2 End of air stream signal Astp Printer dwell time PDTSave parameter in data bank Save Load data bank LoadProduct menu Page Configuration menu Possible adjustmentsCalling the configuration menu Possible testsHandling the menu Display Function of the parameter Possible data entryMenu functions Automatic product speed followerAPSF Type of applicator ApplAdditional functions in the standard menu Input and sensor check ICHOutput check OCH Adjustment resettingFACT Interface baud rate BaudParity bit Pari Number of stop bits SbitNumber of data bits Dbit Recycle simulates max labels/min RecyDistance sensor to dispensing edge Dist Label counter LabcLeave Menu finishing Quit Dispenser connector Signal description Pol D Serial interfaceData of the serial interface Direction Code Description 25 pol Pol SubExample Interface commandsCommand Description Range Ledg Message in display Connections and signals Output signalsSignals for direct dispense Applicator modesControl signals for the ASA applicator Timing ASA applicatorSignals for the EP applicator APT2Applicator connector Applicator connectorInput signals Connecting NPN left or PNP right inputsExample for connecting an NPN sensor Datalogic Product sensorOD Control sensor NPN connection of optional ODC sensorApsf sensor Connection of a NPN type Apsf sensorControl signals Optional connector for process controInternal I/O connector EMI RuleElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page Errors and warnings Dispenser error messagesSTO! Power-fail message Message Meaning How to solveInto Dispenser warnings EepromALS 330/430 Description Details 330 430 Technical specificationTechnical Information Application specification APSF- Sensor Specification Optional functionPerformance charts ChartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Adjustment Function Factory ApplicationFunction Factory PD01 PD02 PD03 PD04 Function PD05 PD06 PD07 PD08 PD09Index