Avery ALS 330/430 manual Into

Page 82

Operators Manual

ALS 330/430

Message

Meaning

How to solve

 

set to the factory adjustment.

 

E__5

10V supply voltage for label

Short circuit in label sensor or cable.

 

sensor low.

Voltage regulator U14 is damaged.

E__6

24V Voltage low

Short circuit on an output. Total load too

 

 

high i.e. max is 3A for all outputs.

 

 

Voltage regulator U1 is damaged.

 

 

Change main board.

E__7

Material initialization failed

Check if the label web is threaded

 

 

through the label sensor

E__8

Error stepper motor driver

The stepper motor control has detected

 

 

an error. The fault is indicated by the

 

 

LED’s on the driver.

E__9

10V supply for label sensor too

Voltage regulator U14 damaged

 

high

 

E__10

Missing label on product

One or several product could not be

 

 

labelled. Distance between products too

 

 

close. Increase speed of printer.

___0

Process error (Divide overflow)

Hardware failure external noise. EPROM

 

 

damaged. Turn off power and on again.

 

 

Change EPROM or main board

___1

Illegal interrupt (processing error)

Hardware failure external noise. EPROM

 

 

damaged. Turn off power and on again.

 

 

Change EPROM or main board

___2

Illegal bank interrupt (processing

Hardware failure external noise. EPROM

 

error)

damaged. Turn off power and on again.

 

 

Change EPROM or main board

INTO

Illegal interrupt INTP0 (processing

Hardware failure external noise. EPROM

 

error)

damaged. Turn off power and on again.

 

 

Change EPROM or main board.

Release 4/06

Page 74

Errors and warnings

Image 82
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Manufacturer Important NotesOverview CopyrightSafety General Safety NotesOperator’s duty of care Concrete security regulations and symbols used Security measures during maintenance and repairs Security measures during normal operationWork on pneumatic equipment Work on the electrical equipmentObserve environmental regulations Description MechanicsMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Preparing the machine InstallationPrepare dispensing Define label data Setting Lpit manually Manual adjustment of the Cont parameterCapacitive label sensor Capacitive sensorLabel guide Adjust dispense functionStop position Label position on the product Fixed dispensing speedAutomatic dispensing speed Apsf Product data bankSafety recommendation OperationInserting label material Left hand version Right hand versionRemoving label material Mounting a new label rollMounting a new label roll on ALS 330 Euro Mounting a new label roll on ALSAdjusting the pressure roller RewindAdjustment of the dispensing edge Lead screw adjustmentPrinter adjustment Adjust pressure roller Initializing new label materialDispenser Menu selection Function Display message Mains switchControl of dispense unit Missing label function and web breaksDispenser active on Display and data inputDisplay Menu function Function data value Material initialisation Init Dispenser stopped OFFLabel position POS Stop position Stod Start delaySTADDispense speed Velo Blow on time Blow MaintenanceProduct menu PD0n Release 4/06 Operation Page Standard menu Configuration menuMenu structure Extended standard menuApplicator ConfigurationStandard menu  Direct Extended menuInitialisation Init Standard menuDisplay Function Values Labelling time Blow Start delay StadDispensing speed Velo Extended standard menu Display Function Data valueLabel contrast Label pitch LpitSensor status Sens Product length Prdl Label positionPOSSlew speed Slew Electronic gear ratio adjustment EgraEgra value check Stst Dwell time APT1Blow on time APT2 Restart delay APT3Time constant compensation APT4 Save parameter in data bank Save End of air stream signal AstpPrinter dwell time PDT Load data bank LoadProduct menu Page Calling the configuration menu Configuration menuPossible adjustments Possible testsHandling the menu Display Function of the parameter Possible data entryMenu functions Automatic product speed followerAPSF Type of applicator ApplOutput check OCH Input and sensor check ICHAdditional functions in the standard menu Parity bit Pari Adjustment resettingFACTInterface baud rate Baud Number of stop bits SbitDistance sensor to dispensing edge Dist Number of data bits DbitRecycle simulates max labels/min Recy Label counter LabcLeave Menu finishing Quit Data of the serial interface Dispenser connector Signal description Pol DSerial interface Direction Code Description 25 pol Pol SubCommand Description Range Interface commandsExample Ledg Message in display Connections and signals Output signalsSignals for direct dispense Applicator modesControl signals for the ASA applicator Timing ASA applicatorSignals for the EP applicator APT2Applicator connector Applicator connectorInput signals Connecting NPN left or PNP right inputsExample for connecting an NPN sensor Datalogic Product sensorOD Control sensor NPN connection of optional ODC sensorApsf sensor Connection of a NPN type Apsf sensorControl signals Optional connector for process controInternal I/O connector EMI RuleElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page STO! Power-fail message Errors and warningsDispenser error messages Message Meaning How to solveInto Dispenser warnings EepromALS 330/430 Technical Information Technical specificationDescription Details 330 430 Application specification APSF- Sensor Specification Optional functionPerformance charts ChartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Adjustment Function Factory ApplicationFunction Factory PD01 PD02 PD03 PD04 Function PD05 PD06 PD07 PD08 PD09Index