Avery ALS 330/430 manual Display and data input, Dispenser active on

Page 33

Operators Manual

ALS 330/430

4.4.3Display and data input

The operator panel controls the operation of the machine. Data can be displayed and changed. The displays have different meanings:

yParameter selection:

In the display a parameter is shown, e.g. POS, STAD, or PD02 (product menu no. 02). By pressing the keys FUNCTION another parameter can be selected. By pressing the key ENTER the data is displayed.

yData display:

The display shows the values of the parameters (e.g. 0123) or possible adjustments e.g. (AUTO). Pressing the FUNCTION keys changes the data value. By pressing the key ENTER the data input is completed and a new parameter is shown.

yError display:

If the display shows e.g. E__XX, the dispenser has recognised an error. A warning is shown by W_XX. As soon as the error has been corrected, you may erase the message by pressing the key ENTER and you will get back to the status the machine was in before the error was indicated.

Note: Data entered in the standard menu are not stored, if the machine is switched off. If you need to store data you have to use the extended menu. Please check if it is of help for you using the product menu in your application.

Display

Menu function

Function data value

ON

Labeller ready

 

 

 

 

OFF

Label function suspend

 

 

 

 

POS

label position on product

Up to 999.9 mm

 

 

 

STOD

Label stop position at the

Depends on setting of DIST, Label

 

dispensing edge

length and RAMP

 

 

 

VELO

Dispensing speed

ALS 330: 0.2 ... 25.0 m/min

 

 

ALS 430: 0.2 ... 18.0 m/min

 

 

 

STAD

delay time before labelling starts

0,1 ... 999,9 ms

 

 

 

BLOW

apply time

0,1 ... 999,9 ms

 

 

 

INIT

Initialisation of label material

Appears after E__0, E__1 and Power

 

(CONT and LPIT are measured

on + FEED key depressed, or if the

 

according to label size)

values of CONT and LPIT are

 

 

changed

 

 

 

Dispenser active ___________________________________________________ ON

The dispenser is able to dispense labels.

Release 4/06

Page 31

Operation

Image 33
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Overview Important NotesManufacturer CopyrightGeneral Safety Notes SafetyOperator’s duty of care Concrete security regulations and symbols used Security measures during normal operation Security measures during maintenance and repairsWork on the electrical equipment Work on pneumatic equipmentObserve environmental regulations Mechanics DescriptionMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Installation Preparing the machinePrepare dispensing Define label data Manual adjustment of the Cont parameter Setting Lpit manuallyCapacitive sensor Capacitive label sensorAdjust dispense function Label guideStop position Automatic dispensing speed Apsf Fixed dispensing speedLabel position on the product Product data bankOperation Safety recommendationLeft hand version Right hand version Inserting label materialMounting a new label roll Removing label materialMounting a new label roll on ALS Mounting a new label roll on ALS 330 EuroRewind Adjusting the pressure rollerLead screw adjustment Adjustment of the dispensing edgePrinter adjustment Initializing new label material Adjust pressure rollerControl of dispense unit Function Display message Mains switchDispenser Menu selection Missing label function and web breaksDisplay and data input Dispenser active onDisplay Menu function Function data value Dispenser stopped OFF Material initialisation InitLabel position POS Start delaySTAD Stop position StodDispense speed Velo Maintenance Blow on time BlowProduct menu PD0n Release 4/06 Operation Page Menu structure Configuration menuStandard menu Extended standard menuStandard menu  Direct ConfigurationApplicator Extended menuStandard menu Initialisation InitDisplay Function Values Start delay Stad Labelling time BlowDispensing speed Velo Display Function Data value Extended standard menuLabel pitch Lpit Label contrastSensor status Sens Label positionPOS Product length PrdlEgra value check Stst Electronic gear ratio adjustment EgraSlew speed Slew Dwell time APT1Restart delay APT3 Blow on time APT2Time constant compensation APT4 Printer dwell time PDT End of air stream signal AstpSave parameter in data bank Save Load data bank LoadProduct menu Page Possible adjustments Configuration menuCalling the configuration menu Possible testsDisplay Function of the parameter Possible data entry Handling the menuMenu functions Type of applicator Appl Automatic product speed followerAPSFInput and sensor check ICH Output check OCHAdditional functions in the standard menu Interface baud rate Baud Adjustment resettingFACTParity bit Pari Number of stop bits SbitRecycle simulates max labels/min Recy Number of data bits DbitDistance sensor to dispensing edge Dist Label counter LabcLeave Menu finishing Quit Serial interface Dispenser connector Signal description Pol DData of the serial interface Direction Code Description 25 pol Pol SubInterface commands Command Description RangeExample Ledg Message in display Output signals Connections and signalsApplicator modes Signals for direct dispenseTiming ASA applicator Control signals for the ASA applicatorAPT2 Signals for the EP applicatorApplicator connector Applicator connectorConnecting NPN left or PNP right inputs Input signalsProduct sensor Example for connecting an NPN sensor DatalogicNPN connection of optional ODC sensor OD Control sensorConnection of a NPN type Apsf sensor Apsf sensorOptional connector for process contro Control signalsInternal I/O connector Rule EMIElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page Dispenser error messages Errors and warningsSTO! Power-fail message Message Meaning How to solveInto Eeprom Dispenser warningsALS 330/430 Technical specification Technical InformationDescription Details 330 430 APSF- Sensor Specification Optional function Application specificationCharts Performance chartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Function Factory Application AdjustmentFunction PD05 PD06 PD07 PD08 PD09 Function Factory PD01 PD02 PD03 PD04Index