Operators Manual
ALS 330/430
8.3.2OD Control sensor
Optional an OD control could be mounted to control the label roll. If the label material is nearly empty the sensor gives an signal. A warning message and an output signal inform the personal that in the next time the material has to be changed.
NPN sensor
Supply
Signal+
Signal-
GND
| 5 | 5 | white |
brown | 9 | 9 | red |
| 4 | 4 |
|
| 8 | 8 |
|
| 3 | 3 |
|
white | 7 | 7 | green |
| 2 | 2 |
|
| 6 | 6 |
|
grey | 1 | 1 | black |
blue
+24V
11
27
25
14
GND
Figure 24 NPN connection of optional ODC sensor
CN33
+24V
PNP sensor
Supply
Signal+
Signal-
GND
brown | 5 | 5 | white |
| |||
white | 9 | 9 | red |
| 4 | 4 |
|
| 8 | 8 |
|
grey | 3 | 3 |
|
| 7 | 7 | green |
| 2 | 2 |
|
| 6 | 6 |
|
blue | 1 | 1 | black |
11
27
25
14
GND
Figure 25 PNP connection of optional ODC sensor
CN33
Release 4/06 | Page 62 | Connections and signals |