Avery ALS 330/430 manual Extended standard menu, Display Function Data value

Page 43

Operators Manual

ALS 330/430

5.2 Extended standard menu

The extended standard menu offers additional parameters you may use in your application. On quitting this menu the current parameter settings are stored in memory. Further changes are also written into memory. As long as this menu is active, no labelling is possible. By pressing the key FEED, however, single dispense of labels is possible.

To get into the extended standard menu a password CODE has to be entered. The display shows the first menu point. A survey of all parameters is shown below.

Display

Function

Data value

 

 

 

LPIT

Label pitch

AUTO/5...999 mm

 

 

 

CONT

Label sensor contrast value

AUTO/1...200

 

 

 

SENS

Sensor status

LAB or GAP

 

 

 

STOD

Stop position of label at the dispensing edge

0.0 .... 200.0 (mm)

 

 

 

PRDL

Product length (inhibit of further product- sensor

AUTO, 5 ... 999 mm

 

signals)

 

 

 

 

 

POS

Position of label on product

Up to 999.9 mm

 

 

 

 

STAD

Delay time for start of applicator cycle

1

... 9999 ms

 

 

 

VELO

Labelling speed

0.2 ... 30 m/min

 

 

 

STST

Check adjusted EGRA value

see text

 

 

 

SLEW

Slew speed

FAST or SLOW

 

 

 

EGRA

Electronic gear ratio adjustment

100 to 500

 

 

 

 

APT1

Dwell time for applicator

1

... 7500 ms

 

 

 

 

APT2

Blow on time for applicator

1

... 7500 ms

 

 

 

 

APT3

Restart delay

0

... 5000 ms

 

 

 

 

APT4

Time constant compensation

0

... 500 ms

 

 

 

ASTP

End of air stream signal

-20 ... 50 mm

 

 

 

PDT

Printer dwell time

OFF - 1000ms

 

 

 

 

Release 4/06

Page 41

Menu structure

Image 43
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Copyright Important NotesOverview ManufacturerGeneral Safety Notes SafetyOperator’s duty of care Concrete security regulations and symbols used Security measures during normal operation Security measures during maintenance and repairsWork on pneumatic equipment Work on the electrical equipmentObserve environmental regulations Mechanics DescriptionMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Preparing the machine InstallationPrepare dispensing Define label data Manual adjustment of the Cont parameter Setting Lpit manuallyCapacitive sensor Capacitive label sensorLabel guide Adjust dispense functionStop position Product data bank Fixed dispensing speedAutomatic dispensing speed Apsf Label position on the productOperation Safety recommendationLeft hand version Right hand version Inserting label materialMounting a new label roll Removing label materialMounting a new label roll on ALS Mounting a new label roll on ALS 330 EuroRewind Adjusting the pressure rollerAdjustment of the dispensing edge Lead screw adjustmentPrinter adjustment Initializing new label material Adjust pressure rollerMissing label function and web breaks Function Display message Mains switchControl of dispense unit Dispenser Menu selectionDispenser active on Display and data inputDisplay Menu function Function data value Material initialisation Init Dispenser stopped OFFLabel position POS Stop position Stod Start delaySTADDispense speed Velo Blow on time Blow MaintenanceProduct menu PD0n Release 4/06 Operation Page Extended standard menu Configuration menuMenu structure Standard menuExtended menu ConfigurationStandard menu  Direct ApplicatorInitialisation Init Standard menuDisplay Function Values Labelling time Blow Start delay StadDispensing speed Velo Display Function Data value Extended standard menuLabel contrast Label pitch LpitSensor status Sens Label positionPOS Product length PrdlDwell time APT1 Electronic gear ratio adjustment EgraEgra value check Stst Slew speed SlewBlow on time APT2 Restart delay APT3Time constant compensation APT4 Load data bank Load End of air stream signal AstpPrinter dwell time PDT Save parameter in data bank SaveProduct menu Page Possible tests Configuration menuPossible adjustments Calling the configuration menuDisplay Function of the parameter Possible data entry Handling the menuMenu functions Type of applicator Appl Automatic product speed followerAPSFOutput check OCH Input and sensor check ICHAdditional functions in the standard menu Number of stop bits Sbit Adjustment resettingFACTInterface baud rate Baud Parity bit PariLabel counter Labc Number of data bits DbitRecycle simulates max labels/min Recy Distance sensor to dispensing edge DistLeave Menu finishing Quit Direction Code Description 25 pol Pol Sub Dispenser connector Signal description Pol DSerial interface Data of the serial interfaceCommand Description Range Interface commandsExample Ledg Message in display Output signals Connections and signalsApplicator modes Signals for direct dispenseTiming ASA applicator Control signals for the ASA applicatorAPT2 Signals for the EP applicatorApplicator connector Applicator connectorConnecting NPN left or PNP right inputs Input signalsProduct sensor Example for connecting an NPN sensor DatalogicNPN connection of optional ODC sensor OD Control sensorConnection of a NPN type Apsf sensor Apsf sensorOptional connector for process contro Control signalsInternal I/O connector Rule EMIElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page Message Meaning How to solve Errors and warningsDispenser error messages STO! Power-fail messageInto Eeprom Dispenser warningsALS 330/430 Technical Information Technical specificationDescription Details 330 430 APSF- Sensor Specification Optional function Application specificationCharts Performance chartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Function Factory Application AdjustmentFunction PD05 PD06 PD07 PD08 PD09 Function Factory PD01 PD02 PD03 PD04Index