4.2.4Lead screw adjustment

For adjustments of the dispensing edge towards or away from the conveyor, the lead screw integrated in the labelling head should be used. Positions can be read from the scale on the dispensing edge bars.

4.2.5Adjustment of the dispensing edge

Loosen handle 1 and 2 and turn lead screw Z. Once the adjustment is completed pull the handles tight again.

Figure 13 Dispensing edge

4.2.6Printer adjustment

If your labeller is equipped with a printer, you adjust the print position as well with the lead screw Z. In this case loosen handle (orange) for printer and handle 1. Once the adjustment is completed, pull the handles tight again.

Release 4/06

Page 28

Operation

Image 30
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Manufacturer Important NotesOverview CopyrightSafety General Safety NotesOperator’s duty of care Concrete security regulations and symbols used Security measures during maintenance and repairs Security measures during normal operationWork on the electrical equipment Work on pneumatic equipmentObserve environmental regulations Description MechanicsMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Installation Preparing the machinePrepare dispensing Define label data Setting Lpit manually Manual adjustment of the Cont parameterCapacitive label sensor Capacitive sensorAdjust dispense function Label guideStop position Label position on the product Fixed dispensing speedAutomatic dispensing speed Apsf Product data bankSafety recommendation OperationInserting label material Left hand version Right hand versionRemoving label material Mounting a new label rollMounting a new label roll on ALS 330 Euro Mounting a new label roll on ALSAdjusting the pressure roller RewindLead screw adjustment Adjustment of the dispensing edgePrinter adjustment Adjust pressure roller Initializing new label materialDispenser Menu selection Function Display message Mains switchControl of dispense unit Missing label function and web breaksDisplay and data input Dispenser active onDisplay Menu function Function data value Dispenser stopped OFF Material initialisation InitLabel position POS Start delaySTAD Stop position StodDispense speed Velo Maintenance Blow on time BlowProduct menu PD0n Release 4/06 Operation Page Standard menu Configuration menuMenu structure Extended standard menuApplicator ConfigurationStandard menu  Direct Extended menuStandard menu Initialisation InitDisplay Function Values Start delay Stad Labelling time BlowDispensing speed Velo Extended standard menu Display Function Data valueLabel pitch Lpit Label contrastSensor status Sens Product length Prdl Label positionPOSSlew speed Slew Electronic gear ratio adjustment EgraEgra value check Stst Dwell time APT1Restart delay APT3 Blow on time APT2Time constant compensation APT4 Save parameter in data bank Save End of air stream signal AstpPrinter dwell time PDT Load data bank LoadProduct menu Page Calling the configuration menu Configuration menuPossible adjustments Possible testsHandling the menu Display Function of the parameter Possible data entryMenu functions Automatic product speed followerAPSF Type of applicator ApplInput and sensor check ICH Output check OCHAdditional functions in the standard menu Parity bit Pari Adjustment resettingFACTInterface baud rate Baud Number of stop bits SbitDistance sensor to dispensing edge Dist Number of data bits DbitRecycle simulates max labels/min Recy Label counter LabcLeave Menu finishing Quit Data of the serial interface Dispenser connector Signal description Pol DSerial interface Direction Code Description 25 pol Pol SubInterface commands Command Description RangeExample Ledg Message in display Connections and signals Output signalsSignals for direct dispense Applicator modesControl signals for the ASA applicator Timing ASA applicatorSignals for the EP applicator APT2Applicator connector Applicator connectorInput signals Connecting NPN left or PNP right inputsExample for connecting an NPN sensor Datalogic Product sensorOD Control sensor NPN connection of optional ODC sensorApsf sensor Connection of a NPN type Apsf sensorControl signals Optional connector for process controInternal I/O connector EMI RuleElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page STO! Power-fail message Errors and warningsDispenser error messages Message Meaning How to solveInto Dispenser warnings EepromALS 330/430 Technical specification Technical InformationDescription Details 330 430 Application specification APSF- Sensor Specification Optional functionPerformance charts ChartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Adjustment Function Factory ApplicationFunction Factory PD01 PD02 PD03 PD04 Function PD05 PD06 PD07 PD08 PD09Index