Operators Manual
ALS 330/430
Description | Details |
| |
330 | 430 | ||
| |||
Operating environment | 5 – 40°C, storage 0 – 70°C |
| |
| 30 - 80%, non condensing |
| |
Power consumption | 300 VA |
| |
|
| ||
Mains voltage | 100V~, 115V~, 200V~ and 230V~ 50/60Hz (6.3A for 110V else | ||
| 3.15A), |
| |
| +5%- 10% |
|
10.1.1 Application specification
The labeller is designed and built for automatic applies of
10.1.2 APSF- Sensor Specification (Optional function)
The resolution of the sensor should be selected in a way, that for 0.15mm product travel a sensor pulse will be generated. Using a different resolution gives loose in label accuracy or limits the highest dispensing speed.
It is possible to use one common sensor for several dispensers. In this case the sensor is supplied from one machine or the several supply voltages switched parallel are separated with diodes.
Supply voltage: | 24 V DC |
Output current: | 20mA for each dispenser |
Signal rise and fall time: | each 1∝s |
Max frequency: | 20 kHz |
Signal ratio: | 1:1 +- 12,5 % |
Connection: | Only shielded cable. The shield has to be grounded on both sides. |
Release 4/06 | Page 78 | Technical specification |