Avery ALS 330/430 Egra value check Stst, Slew speed Slew, Electronic gear ratio adjustment Egra

Page 46

Operators Manual

ALS 330/430

Start delay ______________________________________________________STAD

Function: Delay time for the dispensing by means of an applicator after the product has passed the product sensor. This value influences the position of the label on the product.

Only available if applicator is used. Range: 1 to 9999 ms

Dispensing speed ________________________________________________VELO

Function: The labelling speed may be adjusted with the parameter VELO. Values between 0.2 and 30.0 m/min are possible. The speed has to be adjusted so that it matches the product speed.

When an applicator is fitted to the machine, this parameter defines how fast the label will be dispensed on to the applicator.

EGRA value check ________________________________________________ STST

Use this function to adjust the EGRA value. If the drive-roller speed is higher than that of the conveyor then increase the EGRA value, if it is lower decrease the EGRA value so that the conveyor speed and drive-roller speed match.

Slew speed _____________________________________________________ SLEW

Function: For some situations the labeller can run with a different, higher speed. This occurs during compensation of a missing label on the web, positioning the label at the dispensing edge during initialisation or after pressing the feed button if the APSF-mode is selected. The resulting speed depends on the selection (FAST or SLOW) and the APSF-mode.

SLEW setting

FAST

SLOW

APSF off

Max speed

VELO

APSF on

Max speed

12 m/min

Electronic gear ratio adjustment ___________________________________ EGRA

The parameter EGRA appears in the extended menu only after the APSF function has been switched on.

The range of the EGRA parameter is 100 to 500, representing from 1 to 5 encoder pulses per millimetre of conveyor movement. The full EGRA range can be used up to 30 m/min conveyor speed.

With an applicator there is no realistic limit to the conveyor speed and at very high-speeds an EGRA value at the lower end of the range should be used.

Dwell time _______________________________________________________ APT1

Function: Only used when an EP- applicator is necessary. It defines for how long the pneumatic cylinder is switched on.

Available only with applicator. Range: 1 ... 7500 ms

Release 4/06

Page 44

Menu structure

Image 46
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Manufacturer Important NotesOverview CopyrightSafety General Safety NotesOperator’s duty of care Concrete security regulations and symbols used Security measures during maintenance and repairs Security measures during normal operationWork on pneumatic equipment Work on the electrical equipmentObserve environmental regulations Description MechanicsMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Preparing the machine InstallationPrepare dispensing Define label data Setting Lpit manually Manual adjustment of the Cont parameterCapacitive label sensor Capacitive sensorLabel guide Adjust dispense functionStop position Label position on the product Fixed dispensing speedAutomatic dispensing speed Apsf Product data bankSafety recommendation OperationInserting label material Left hand version Right hand versionRemoving label material Mounting a new label rollMounting a new label roll on ALS 330 Euro Mounting a new label roll on ALSAdjusting the pressure roller RewindAdjustment of the dispensing edge Lead screw adjustmentPrinter adjustment Adjust pressure roller Initializing new label materialDispenser Menu selection Function Display message Mains switchControl of dispense unit Missing label function and web breaksDispenser active on Display and data inputDisplay Menu function Function data value Material initialisation Init Dispenser stopped OFFLabel position POS Stop position Stod Start delaySTADDispense speed Velo Blow on time Blow MaintenanceProduct menu PD0n Release 4/06 Operation Page Standard menu Configuration menuMenu structure Extended standard menuApplicator ConfigurationStandard menu  Direct Extended menuInitialisation Init Standard menuDisplay Function Values Labelling time Blow Start delay StadDispensing speed Velo Extended standard menu Display Function Data valueLabel contrast Label pitch LpitSensor status Sens Product length Prdl Label positionPOSSlew speed Slew Electronic gear ratio adjustment EgraEgra value check Stst Dwell time APT1Blow on time APT2 Restart delay APT3Time constant compensation APT4 Save parameter in data bank Save End of air stream signal AstpPrinter dwell time PDT Load data bank LoadProduct menu Page Calling the configuration menu Configuration menuPossible adjustments Possible testsHandling the menu Display Function of the parameter Possible data entryMenu functions Automatic product speed followerAPSF Type of applicator ApplOutput check OCH Input and sensor check ICHAdditional functions in the standard menu Parity bit Pari Adjustment resettingFACTInterface baud rate Baud Number of stop bits SbitDistance sensor to dispensing edge Dist Number of data bits DbitRecycle simulates max labels/min Recy Label counter LabcLeave Menu finishing Quit Data of the serial interface Dispenser connector Signal description Pol DSerial interface Direction Code Description 25 pol Pol SubCommand Description Range Interface commandsExample Ledg Message in display Connections and signals Output signalsSignals for direct dispense Applicator modesControl signals for the ASA applicator Timing ASA applicatorSignals for the EP applicator APT2Applicator connector Applicator connectorInput signals Connecting NPN left or PNP right inputsExample for connecting an NPN sensor Datalogic Product sensorOD Control sensor NPN connection of optional ODC sensorApsf sensor Connection of a NPN type Apsf sensorControl signals Optional connector for process controInternal I/O connector EMI RuleElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page STO! Power-fail message Errors and warningsDispenser error messages Message Meaning How to solveInto Dispenser warnings EepromALS 330/430 Technical Information Technical specificationDescription Details 330 430 Application specification APSF- Sensor Specification Optional functionPerformance charts ChartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Adjustment Function Factory ApplicationFunction Factory PD01 PD02 PD03 PD04 Function PD05 PD06 PD07 PD08 PD09Index