7.2 Interface commands

The below described commands will change one of the labelling parameter. The values are not stored and will be lost when turning off power.

If the sequence nnnn is replaced by the character "?" then the current value of that parameter will be returned by the labelling machine as a 4 character string confirming the name of the parameter requested followed by 4 numbers representing the current value of that parameter. The character 04H terminates all return messages.

Example

 

 

 

 

PC send the message:

#!VELO?

 

 

Machine returns:

 

VELO0300<04H>

 

 

 

 

 

Command

Description

Range

#!APOSnnnn

Value APOS

-0050 – 0100 mm

 

 

 

#!APPLnnnn

Applicator type

0000 direct dispense

 

 

 

0001 ASA

 

 

 

0002 EP

 

 

 

0003 EP_U

 

 

 

0004 PLUA

 

 

 

0005 INDX

 

 

 

#!APSFnnnn

APSF function

0000 off

 

 

 

0001 on

 

 

 

 

#!APT1nnnn

Applicator time

0001

– 7500 ms

 

 

 

 

#!APT2nnnn

Applicator time

0001

– 7500 ms

 

 

 

 

#!APT3nnnn

Applicator time

0000

– 5000 ms

 

 

 

#!ASTPnnnn

Value ASTP

-0020 – 0050 mm

 

 

 

 

#!BANKnnnn

Change product bank

0000

- 0009

 

 

 

 

#!BLOWnnnn

Blow on time = APT 2

0001

- 7500 ms

 

 

 

 

#!COMPnnnn

Automatic label compensation

0000

= Off

 

 

 

0001

= On

 

 

 

 

#!CONTnnnn

Material contrast

0001

– 0200

 

 

 

0000 automatically

 

 

 

 

#!DISTnnnn

Distance label sensor – dispensing

0080

– 9999 * 0.1 mm

 

edge

 

 

 

#!EGRAnnn

Gear ratio

0300

– 1000

 

 

 

 

#!LPITnnnn

Label length

0005

– 0999 mm

 

 

 

0000 automatically

 

 

 

#!MACHnnnn

Machine type

0000 ALS230

 

 

 

0001 ALX720

 

 

 

0002 ALS330

 

 

 

0003 ALS430

 

 

 

 

#!MDIRnnnn

Motor direction

0000

Right --- >

Release 4/06

Page 52

Serial interface

Image 60
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Important Notes OverviewManufacturer CopyrightSafety General Safety NotesOperator’s duty of care Concrete security regulations and symbols used Security measures during maintenance and repairs Security measures during normal operationWork on the electrical equipment Work on pneumatic equipmentObserve environmental regulations Description MechanicsMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Installation Preparing the machinePrepare dispensing Define label data Setting Lpit manually Manual adjustment of the Cont parameterCapacitive label sensor Capacitive sensorAdjust dispense function Label guideStop position Fixed dispensing speed Automatic dispensing speed ApsfLabel position on the product Product data bankSafety recommendation OperationInserting label material Left hand version Right hand versionRemoving label material Mounting a new label rollMounting a new label roll on ALS 330 Euro Mounting a new label roll on ALSAdjusting the pressure roller RewindLead screw adjustment Adjustment of the dispensing edgePrinter adjustment Adjust pressure roller Initializing new label materialFunction Display message Mains switch Control of dispense unitDispenser Menu selection Missing label function and web breaksDisplay and data input Dispenser active onDisplay Menu function Function data value Dispenser stopped OFF Material initialisation InitLabel position POS Start delaySTAD Stop position StodDispense speed Velo Maintenance Blow on time BlowProduct menu PD0n Release 4/06 Operation Page Configuration menu Menu structureStandard menu Extended standard menuConfiguration Standard menu  DirectApplicator Extended menuStandard menu Initialisation InitDisplay Function Values Start delay Stad Labelling time BlowDispensing speed Velo Extended standard menu Display Function Data valueLabel pitch Lpit Label contrastSensor status Sens Product length Prdl Label positionPOSElectronic gear ratio adjustment Egra Egra value check StstSlew speed Slew Dwell time APT1Restart delay APT3 Blow on time APT2Time constant compensation APT4 End of air stream signal Astp Printer dwell time PDTSave parameter in data bank Save Load data bank LoadProduct menu Page Configuration menu Possible adjustmentsCalling the configuration menu Possible testsHandling the menu Display Function of the parameter Possible data entryMenu functions Automatic product speed followerAPSF Type of applicator ApplInput and sensor check ICH Output check OCHAdditional functions in the standard menu Adjustment resettingFACT Interface baud rate BaudParity bit Pari Number of stop bits SbitNumber of data bits Dbit Recycle simulates max labels/min RecyDistance sensor to dispensing edge Dist Label counter LabcLeave Menu finishing Quit Dispenser connector Signal description Pol D Serial interfaceData of the serial interface Direction Code Description 25 pol Pol SubInterface commands Command Description RangeExample Ledg Message in display Connections and signals Output signalsSignals for direct dispense Applicator modesControl signals for the ASA applicator Timing ASA applicatorSignals for the EP applicator APT2Applicator connector Applicator connectorInput signals Connecting NPN left or PNP right inputsExample for connecting an NPN sensor Datalogic Product sensorOD Control sensor NPN connection of optional ODC sensorApsf sensor Connection of a NPN type Apsf sensorControl signals Optional connector for process controInternal I/O connector EMI RuleElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page Errors and warnings Dispenser error messagesSTO! Power-fail message Message Meaning How to solveInto Dispenser warnings EepromALS 330/430 Technical specification Technical InformationDescription Details 330 430 Application specification APSF- Sensor Specification Optional functionPerformance charts ChartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Adjustment Function Factory ApplicationFunction Factory PD01 PD02 PD03 PD04 Function PD05 PD06 PD07 PD08 PD09Index