Avery ALS 330/430 manual Label guide, Adjust dispense function, Stop position

Page 23

Operators Manual

ALS 330/430

3.3 Label guide

On some of the axles, they’re guiding clamps. Adjust the clamps near the machine so all have the same distance to the front plate (31.5mm). The outer clamps should be mounted that the guide but not bend the label material.

The front of the V-dispensing edge has a rot, which can be adjusted for straighten the material guiding. Spend several labels by pressing the dispenser FEED key. If the material guiding is running out of the guiding way, adjust the rot by loosing two screws at the dispensing edge. With a L-dispensing the adjustment is done by move the tail sheaves behind the dispensing edge.

3.4 Adjust dispense function

For an operation without any trouble and high label accuracy, tree adjustments are required:

Label position on the dispensing edge: stop position

Dispense speed

Label position on the product

The adjustment should be done in the same order, because parameter like the stop position depends on the setting of the stop position and the dispensing speed.

3.4.1Stop position

The first step is to adjust the stop position. This is the basic adjustment of the dispense process. Also in case of problems with the machine check if the stop position is okay.

Figure 6 Stop position

The stop position should be adjusted so that the label stops at the dispensing edge up to 3 mm behind.

For a correct operation of the automatic label compensation, they will compensate a missing label on the web, first the distance between label sensor and dispensing edge has to be defined. Do this by calling the DIST function in the configuration menu. Check the setting by removing a label before the label sensor from the web. Give a start signal to the machine by triggering the start sensor (not the FEED key) and see if the compensation is done on the right position. Do the fine adjustment with the STOD function.

Release 4/06

Page 21

Preparing the machine

Image 23
Contents Page Page ALS 330/430 Menu structure Errors and warnings ALS 330/430 Copyright Important NotesOverview ManufacturerGeneral Safety Notes SafetyOperator’s duty of care Concrete security regulations and symbols used Security measures during normal operation Security measures during maintenance and repairsObserve environmental regulations Work on the electrical equipmentWork on pneumatic equipment Mechanics DescriptionMachine layout Operator panel Operator panelPlug board Plug boardElectronics ALS 330/430 Prepare dispensing InstallationPreparing the machine Define label data Manual adjustment of the Cont parameter Setting Lpit manuallyCapacitive sensor Capacitive label sensorStop position Adjust dispense functionLabel guide Product data bank Fixed dispensing speedAutomatic dispensing speed Apsf Label position on the productOperation Safety recommendationLeft hand version Right hand version Inserting label materialMounting a new label roll Removing label materialMounting a new label roll on ALS Mounting a new label roll on ALS 330 EuroRewind Adjusting the pressure rollerPrinter adjustment Lead screw adjustmentAdjustment of the dispensing edge Initializing new label material Adjust pressure rollerMissing label function and web breaks Function Display message Mains switchControl of dispense unit Dispenser Menu selectionDisplay Menu function Function data value Display and data inputDispenser active on Label position POS Dispenser stopped OFFMaterial initialisation Init Dispense speed Velo Start delaySTADStop position Stod Product menu PD0n MaintenanceBlow on time Blow Release 4/06 Operation Page Extended standard menu Configuration menuMenu structure Standard menuExtended menu ConfigurationStandard menu  Direct ApplicatorDisplay Function Values Standard menuInitialisation Init Dispensing speed Velo Start delay StadLabelling time Blow Display Function Data value Extended standard menuSensor status Sens Label pitch LpitLabel contrast Label positionPOS Product length PrdlDwell time APT1 Electronic gear ratio adjustment EgraEgra value check Stst Slew speed SlewTime constant compensation APT4 Restart delay APT3Blow on time APT2 Load data bank Load End of air stream signal AstpPrinter dwell time PDT Save parameter in data bank SaveProduct menu Page Possible tests Configuration menuPossible adjustments Calling the configuration menuDisplay Function of the parameter Possible data entry Handling the menuMenu functions Type of applicator Appl Automatic product speed followerAPSFAdditional functions in the standard menu Input and sensor check ICHOutput check OCH Number of stop bits Sbit Adjustment resettingFACTInterface baud rate Baud Parity bit PariLabel counter Labc Number of data bits DbitRecycle simulates max labels/min Recy Distance sensor to dispensing edge DistLeave Menu finishing Quit Direction Code Description 25 pol Pol Sub Dispenser connector Signal description Pol DSerial interface Data of the serial interfaceExample Interface commandsCommand Description Range Ledg Message in display Output signals Connections and signalsApplicator modes Signals for direct dispenseTiming ASA applicator Control signals for the ASA applicatorAPT2 Signals for the EP applicatorApplicator connector Applicator connectorConnecting NPN left or PNP right inputs Input signalsProduct sensor Example for connecting an NPN sensor DatalogicNPN connection of optional ODC sensor OD Control sensorConnection of a NPN type Apsf sensor Apsf sensorOptional connector for process contro Control signalsInternal I/O connector Rule EMIElectronic diagrams Wiring diagram Layout dispenser electronic board Resolution ALS 330/430 Page Message Meaning How to solve Errors and warningsDispenser error messages STO! Power-fail messageInto Eeprom Dispenser warningsALS 330/430 Description Details 330 430 Technical specificationTechnical Information APSF- Sensor Specification Optional function Application specificationCharts Performance chartsPerformance chart Ramp Norm Deceleration Labels/min 900 25 mm 50 mm 75 mm 800 ALS 330/430 Page Function Factory Application AdjustmentFunction PD05 PD06 PD07 PD08 PD09 Function Factory PD01 PD02 PD03 PD04Index