Teledyne 4060 manual Specifications and Initial Settings, Series Appendix

Page 75

Series 4060

Appendix

 

 

 

Appendix

A.1 Specifications and Initial Settings:

Range(s): Refer to Addendum and Testing Results in Appendix B.

Power Requirements: Refer to Addendum and Testing Results in Appendix B.

Signal Output: Two analog channels:

Channel 1: 0-1 VDC and isolated 4-20 mADC

Channel 2: 0-1 VDC and isolated 4-20 mADC

User configurable as: Benzene, other aromatics, Total HC, and Peak traces.

Alarms: Two Concentration Alarm ‘C’ Type relay contacts. User

configurable.

One System Alarm for AC power failure and flame out, fail safe, ‘C’ type relay contacts.

Calibration Contact: Calibration Contact, ‘A’ Type Relay contact for span mode indication.

RS-232 Output: Provided

Ambient Temp: 0 – 40º C. Install in a well ventilated area

Teledyne Analytical Instruments

75

Image 75
Contents Series Teledyne Analytical Instruments SeriesTeledyne Analytical Instruments Iii Safety MessagesSeries Combustible GAS Usage Additional Safety InformationSeries Teledyne Analytical Instruments Vii Procedure for Removal of Internal Inaccessible Shock HazardsViii Table of Contents Operation Maintenance & Troubleshooting Appendix B AppendixTeledyne Analytical Instruments Xiii List of FiguresList of Tables Main Features of the Analyzer IntroductionSeries Introduction Principle of Operation Analyzer DescriptionIntroduction Series Model 4060 Front Panel Interface Applications Series Operational Theory Operational TheoryIntroduction Modes of OperationAnalyzer Subsystems Operational Theory SeriesSample System Gas Flow Control System Internal Temperature ControllersFlame Ionization Detection Cell Fuel and Blanket Air SystemsTypical Piping Diagram for the Model Detection Cell Flame Ionization Cell Electrometer-AmplifierAnode Power Supply Flame Guard CircuitFlame Ignition Circuit Mounting the Analyzer InstallationSeries Installation Unpacking the AnalyzerElectronic Connections Installation SeriesElectrical Power Connections User ConnectionsModel 4060 Rear Panel with Optional Gas Manifold Equipment Interface Connector Pin Arrangement Pin Function Threshold Alarm System Alarm Remote Calibration Connections Range ID Relay Connections 2.10 RS-232 Port Pin out of 50 pin D-Sub ConnectorGas Connections Commands via RS-232 InputGas Connections Less than 0.5 PPM Placing the System in Operation Operation EquipmentSeries Operation Preliminary Power-Off Check List Activating the Support GasesOperation Series Span Gas Flame Ignition1 Air Carrier GasIgnition and/or Flame Guard Circuit Failure Sample PumpAnalyzer Operation Verification of the Flame Guard CircuitSeries Operation Style Conventions Default ParametersEnter Navigation and Data EntryMenu Structure EscapeMain Menus Span System Self-Diagnostic Test ALT-SPANModel Screen Alarms Function AL-1 Defeated AL-1 High AL-1 NON-FAILSAFE AL-1 NON-LATCHING Operation Series Range Function Analog Output AdjustmentSetting up an AUTO-CAL LinearizationChanging Stream Autocal Password Group Setup Password ProtectionTiming Entering a Password Enter NEW Password Screen Logging Out Repeat Password Entry ScreenStandby Series Operation Operation Series Teledyne Analytical Instruments Series Maintenance Maintenance & TroubleshootingMaintenance Series Measuring Circuit Electrical ChecksAnode Voltage Check Electronic Stability Printed Circuit Board ReplacementCollector Cable Temperature Control Electronic CheckIgnition and/or Flame Guard Circuit Checks Sampling System Printed Circuit Board Descriptions Flame Guard and Anode Power Supply PCBProportional Temperature Controller PCB Electrometer-Amplifier PCB Maintenance Series Specifications and Initial Settings AppendixSeries Appendix Recommended Spare Parts List Appendix SeriesAnalytical Instruments PC Board Assemblies Drawing ListAppendix Series Teledyne Analytical Instruments Appendix B B1 Addendum and Testing Results