Bosch Appliances UPH-2D, UPH-Z Washer Pipe, Nut, Nosecap, Coupling, Noseclip, Delivery Hose

Page 18

18 en Connecting the Washer Pump (optional)

High Speed Pan/Tilt System

 

 

2.Insert the cables inside the mount so they protrude approximately 0.5 m (19.7 in.).

3.Insert the cable into the cable glands and, keeping the base at about 20 cm (7.9 in.) from the support, lock the cable glands.

4.Set the base on the mount, aiding the cables to achieve the correct position inside.

5.Attach the base to the mount using the supplied screws.

6.Cut the cables to size and either restore or make the connections to the positioning unit.

7.After you have attached the base to the mount, shorten the washer pipe as required and attach it to the coupling as follows:

a.unfasten the nut from the coupling,

b.insert it into the pipe,

c.insert the end of the pipe onto the nosecap.

d.Lock the nut to the coupling (see Figure 5.2).

1

5

2 3

6

7

4

8

9

Fig. 5.2 Installing the Washer Pipe

Reference #

Description

 

 

1

Washer Pipe

 

 

2

Nut

 

 

3

Nosecap

 

 

4

Coupling

 

 

5

Bracket

 

 

6

Noseclip

 

 

7

Screws

 

 

8

Washers

 

 

9

Delivery Hose

 

 

8.Attach the pipe to the washer support using the supplied bracket, screws, and washers.

9.Lock the coupling using the supplied hoseclip and connect the delivery hose.

10.Calibrate the jet (see Figure 5.3) by directing the nozzle towards the glass of the housing.

F01U.073.990 Version 1.0 2007.07

Instruction Manual

Bosch Security Systems

Image 18
Contents High Speed Pan/Tilt System Page Table of Contents Configuring the System Safety Important safety instructionsSafety precautions Important notices Coax groundingCopyright TrademarksTools Required Parts List2Unpacking Small, straight-blade screwdriver 2.5 mm 0.1Safety Rules 3DescriptionInstalling the High Speed Pan/Tilt Mounting the High Speed Pan/TiltWarranties are void Outdoor Wall Mount for UPH Series DescriptionOutdoor Pole Mount for UPH Series Pole Adapter for MTC-WUPHReference # Description Base Gasket Screw Ring Washer Bracket SupportWiring the Video Cable Tie Threads used to Group and Secure Signal CablesWire Color VAC Terminal Connection Connecting the Power SupplyThat the disconnecting switch is open Per local Installer Neutral Live/Active Green/Yellow EarthWiring Biphase RS-232 is used for firmware upgrades only see Figure5RS-232 Connecting the Washer Pump optional Nosecap Washer PipeNut CouplingCalibrating the Nozzle Reference Description AL1Connecting the Peripherals Base with 19-pin Connector for Connecting PeripheralsSalt Bag Metal Fixing AccessoryAttaching the Top Unit Fixing ScrewsAligning the Tabs Screw Configuration WindowPlace safety label near unit that warns of moving parts Screw SealRocker for DIP switch No is OFF PROGRAM. OFF Configuring the DeviceBaud Rate Switches For updating the firmwareProtocol Baud Rate Menu setup OSD Protocol SwitchesSetting the Address Pelco D 2400 Preset Biphase Auto AUX-On BilinxAddress Combinations 4Connections Intuikeyboard RS-485 Divar BiphaseRS-485 Biphase Bilinx/Video Intuikeyboard AllegiantRS485-2 EthernetEthernet VideoSwitching On and Off Configuring the DeviceTo configure the UPH, proceed as follows Moving Around the Menus Using the JoystickOn-screen Display OSD Open or Iris Close buttonPresets 10.1 Keyboard Commands ListSetup and Configuration Auxiliary Connections10.3 Changing the Numeric Fields Configuring the System10.2 Changing the Settings Main menu by pressing AUX on 200 Enter11.2 Display Setup Menu 11.1 Language MenuPlayed on the screen Feature Description Default Options Area Parameters Menu Enables / disables the on-screen messageBy the device Enables the user to edit a customized, on Depending on the horizontal position reachedSetting the Area Position Values Changing the Edit Text MenuDisplay Parameters Offset PanWiper-washer, and the alarm settings of the UPH 11.3 Motion Parameters MenuSpeed Menu Data is expressed as degrees per second PAN SpeedTilt Speed Limits Preset/Patrol/Autopan Feature DescriptionPreset Menu Special Preset Parameters Home Position Reached SpeedEND Position Patrol loading of preset positionsStart Position First Prst SpeedAutopan menu is used to indicate preset position settings AutopanMotions Recall Menu Wiper-Washer Alarms 11.4 Camera ParametersUPH-2D and UPH-3D Series DinionXF Cameras UPH-Z Series camera module Zoom Parameters MenuFocus Parameters menu is used to enable focus settings Focus Parameters MenuParameters Mode Infrared Menu Auto Exposure Parameters MenuDynamic Masking UPH-Z Series only Position Recall Mask NRMask Changing Changing ColourPTZ Mode Masking 11.5 Creating a New Dynamic MaskBack Light Compen SATImage Stabilization Load Default menu is used to load the default settings 11.6 Load Default Configuration11.7 Setup Info Menu UPH boards12.2 Replacing the Fuses Maintenance12.1 Cleaning Voltage Fuse F1 Fuse F2Troubleshooting Problem Possible Cause SolutionTroubleshooting Error 13.1 Dimensions and Range of Movement 514 584R385 Technical Specifications Bosch Security Systems