Bosch Appliances UPH-Z, UPH-2D, UPH-3D instruction manual 3Description, Safety Rules

Page 10

10 en DescriptionHigh Speed Pan/Tilt System

2.3

Safety Rules

To ensure safety, the following warnings are specified:

The device must be installed and maintained by skilled technical personnel.

Connect the device to a power source corresponding to the indications given on the marking label.

The device has been designed for permanent installation in a building or other suitable structure.

Moving parts may result in risk of injury, therefore, the device should be mounted so that it is accessible only to the technician/installer.

Place the safety label near the UPH. See Figure 6.4 for illustration of safety label.

Before carrying out any technical work on the UPH, tilt the UPH all the way up or all the way down, then disconnect the power supply and cables from all other devices.

Do not use power cables with signs of wear or aging.

Do not use the device in the presence of inflammable substances.

Do not allow children or unauthorized personnel to use the device.

The device should be switched OFF when the power supply has been disconnected and the connecting cables to other devices have been removed.

Keep this manual for future reference.

CAUTION! Before disconnecting the power supply to the UPH, tilt the device either all the way up or all the way down. When the UPH loses power,

!depending on how it is positioned, the unit may drop slightly forward or backward. Therefore, failure in correctly positioning the UPH before disconnecting the power supply may result in personal injury or possible damage to the device.

3Description

The Bosch High-Speed Positioning System is a complete, high-performance, high quality solu- tion that can pan 360 degrees continuously at speeds of up to 100 degrees per second. An extensive range of options lets you tailor the system to your specific requirements. For exam-

ple, a wide variety of video cameras and lenses, including the optimized DinionXF camera and zoom combinations, are available.

F01U.073.990 Version 1.0 2007.07

Instruction Manual

Bosch Security Systems

Image 10
Contents High Speed Pan/Tilt System Page Table of Contents Configuring the System Safety Important safety instructionsSafety precautions Important notices Coax groundingCopyright TrademarksTools Required Parts List2Unpacking Small, straight-blade screwdriver 2.5 mm 0.1Safety Rules 3DescriptionMounting the High Speed Pan/Tilt Installing the High Speed Pan/TiltWarranties are void Outdoor Wall Mount for UPH Series DescriptionOutdoor Pole Mount for UPH Series Pole Adapter for MTC-WUPHReference # Description Base Gasket Screw Ring Washer Bracket SupportWiring the Video Cable Tie Threads used to Group and Secure Signal CablesWire Color VAC Terminal Connection Connecting the Power SupplyThat the disconnecting switch is open Per local Installer Neutral Live/Active Green/Yellow EarthRS-232 is used for firmware upgrades only see Figure Wiring Biphase5RS-232 Connecting the Washer Pump optional Nosecap Washer PipeNut CouplingCalibrating the Nozzle Reference Description AL1Connecting the Peripherals Base with 19-pin Connector for Connecting PeripheralsSalt Bag Metal Fixing AccessoryAttaching the Top Unit Fixing ScrewsAligning the Tabs Screw Configuration WindowPlace safety label near unit that warns of moving parts Screw SealRocker for DIP switch No is OFF PROGRAM. OFF Configuring the DeviceBaud Rate Switches For updating the firmwareProtocol Baud Rate Menu setup OSD Protocol SwitchesSetting the Address Pelco D 2400 Preset Biphase Auto AUX-On BilinxAddress Combinations 4Connections Intuikeyboard RS-485 Divar BiphaseRS-485 Biphase Bilinx/Video Intuikeyboard AllegiantRS485-2 EthernetEthernet VideoConfiguring the Device Switching On and OffTo configure the UPH, proceed as follows Moving Around the Menus Using the JoystickOn-screen Display OSD Open or Iris Close buttonPresets 10.1 Keyboard Commands ListSetup and Configuration Auxiliary Connections10.3 Changing the Numeric Fields Configuring the System10.2 Changing the Settings Main menu by pressing AUX on 200 Enter11.1 Language Menu 11.2 Display Setup MenuPlayed on the screen Feature Description Default Options Area Parameters Menu Enables / disables the on-screen messageBy the device Enables the user to edit a customized, on Depending on the horizontal position reachedSetting the Area Position Values Changing the Edit Text MenuDisplay Parameters Offset Pan11.3 Motion Parameters Menu Wiper-washer, and the alarm settings of the UPHSpeed Menu PAN Speed Data is expressed as degrees per secondTilt Speed Limits Preset/Patrol/Autopan Feature DescriptionPreset Menu Special Preset Parameters Home Position Reached SpeedEND Position Patrol loading of preset positionsStart Position First Prst SpeedAutopan Autopan menu is used to indicate preset position settingsMotions Recall Menu Wiper-Washer Alarms 11.4 Camera ParametersUPH-2D and UPH-3D Series DinionXF Cameras UPH-Z Series camera module Zoom Parameters MenuFocus Parameters menu is used to enable focus settings Focus Parameters MenuAuto Exposure Parameters Menu Parameters Mode Infrared MenuDynamic Masking UPH-Z Series only Position Recall Mask NRMask Changing Changing ColourPTZ Mode Masking 11.5 Creating a New Dynamic MaskSAT Back Light CompenImage Stabilization Load Default menu is used to load the default settings 11.6 Load Default Configuration11.7 Setup Info Menu UPH boards12.2 Replacing the Fuses Maintenance12.1 Cleaning Voltage Fuse F1 Fuse F2Problem Possible Cause Solution TroubleshootingTroubleshooting Error 13.1 Dimensions and Range of Movement 514 584R385 Technical Specifications Bosch Security Systems