Bosch Appliances UPH-Z Configuring the System, Changing the Settings, Changing the Numeric Fields

Page 34

34 en Configuring the SystemHigh Speed Pan/Tilt System

10.2

Changing the Settings

To change a setting, proceed as follows:

1.AUX ON - 200 - Enter to enable the OSD.

2.Move the cursor to the parameter to be changed.

3.Press the confirmation (Focus) button. The field starts flashing, indicating that it is in change mode. Operating the joystick (up and down) shows the alternative choices.

4.After identifying the desired selection, press the confirmation (Focus) button; the param- eter stops flashing.

Note: For UPH-2D and UPH-3D Series (DinionXF) models, use up and down to scroll through the menus, Focus to enter a submenu, and left and right to change values.

10.3

Changing the Numeric Fields

To change a numeric field, proceed as follows:

1.Use the joystick to scroll to the parameter you would like to edit.

2.Press the confirmation (Focus) button. The cursor starts flashing for the character to be changed, indicating it is in edit mode.

The minimum and maximum values allowed are displayed at the bottom of the screen. If you try to insert a value outside the limits, the field is forced to the mini- mum or maximum allowed value.

Operating the joystick (up and down) shows the alternative choices. If there is more than one field on the same line, it is necessary to select the field by moving the joy- stick (left and right).

3.After making the change, press the confirmation (Focus) button.

The first digit in the numeric field to be changed flashes and the last line of the dis- play shows the accepted limits for the field.

Move within the field (left and right) and change the sign or the numeric value (up and down).

Note: For UPH-2D and UPH-3D Series (DinionXF) models, use up and down to scroll through the menus, Focus to enter a submenu, and left and right to change values.

11

Configuring the System

 

The UPH High Speed Pan/Tilt can be configured through the on-screen display (OSD). Open

 

the main menu by pressing AUX ON - 200 - Enter.

 

 

 

 

 

MAIN MENU

 

 

 

 1

- LANGUAGE



 

 

2

- DISPLAY SETUP



 

 

3

- MOTION PARAMETERS



 

 

4

- CAMERA PARAMETERS



 

 

5

- LOAD DEFAULT CONFIGUR. 

 

 

6

- SETUP INFO



 

 

 

 

 

 

Fig. 11.1 OSD (On-screen Display) Main Menu

F01U.073.990 Version 1.0 2007.07

Instruction Manual

Bosch Security Systems

Image 34
Contents High Speed Pan/Tilt System Page Table of Contents Configuring the System Safety Important safety instructionsSafety precautions Important notices Coax groundingCopyright TrademarksTools Required Parts List2Unpacking Small, straight-blade screwdriver 2.5 mm 0.1Safety Rules 3DescriptionMounting the High Speed Pan/Tilt Installing the High Speed Pan/TiltWarranties are void Outdoor Wall Mount for UPH Series DescriptionOutdoor Pole Mount for UPH Series Pole Adapter for MTC-WUPHReference # Description Base Gasket Screw Ring Washer Bracket SupportWiring the Video Cable Tie Threads used to Group and Secure Signal CablesWire Color VAC Terminal Connection Connecting the Power SupplyThat the disconnecting switch is open Per local Installer Neutral Live/Active Green/Yellow EarthRS-232 is used for firmware upgrades only see Figure Wiring Biphase5RS-232 Connecting the Washer Pump optional Nosecap Washer PipeNut CouplingCalibrating the Nozzle Reference Description AL1Connecting the Peripherals Base with 19-pin Connector for Connecting PeripheralsSalt Bag Metal Fixing AccessoryAttaching the Top Unit Fixing ScrewsAligning the Tabs Screw Configuration WindowPlace safety label near unit that warns of moving parts Screw SealRocker for DIP switch No is OFF PROGRAM. OFF Configuring the DeviceBaud Rate Switches For updating the firmwareProtocol Baud Rate Menu setup OSD Protocol SwitchesSetting the Address Pelco D 2400 Preset Biphase Auto AUX-On BilinxAddress Combinations 4Connections Intuikeyboard RS-485 Divar BiphaseRS-485 Biphase Bilinx/Video Intuikeyboard AllegiantRS485-2 EthernetEthernet VideoConfiguring the Device Switching On and OffTo configure the UPH, proceed as follows Moving Around the Menus Using the JoystickOn-screen Display OSD Open or Iris Close buttonPresets 10.1 Keyboard Commands ListSetup and Configuration Auxiliary Connections10.3 Changing the Numeric Fields Configuring the System10.2 Changing the Settings Main menu by pressing AUX on 200 Enter11.1 Language Menu 11.2 Display Setup MenuPlayed on the screen Feature Description Default Options Area Parameters Menu Enables / disables the on-screen messageBy the device Enables the user to edit a customized, on Depending on the horizontal position reachedSetting the Area Position Values Changing the Edit Text MenuDisplay Parameters Offset Pan11.3 Motion Parameters Menu Wiper-washer, and the alarm settings of the UPHSpeed Menu PAN Speed Data is expressed as degrees per secondTilt Speed Limits Preset/Patrol/Autopan Feature DescriptionPreset Menu Special Preset Parameters Home Position Reached SpeedEND Position Patrol loading of preset positionsStart Position First Prst SpeedAutopan Autopan menu is used to indicate preset position settingsMotions Recall Menu Wiper-Washer Alarms 11.4 Camera ParametersUPH-2D and UPH-3D Series DinionXF Cameras UPH-Z Series camera module Zoom Parameters MenuFocus Parameters menu is used to enable focus settings Focus Parameters MenuAuto Exposure Parameters Menu Parameters Mode Infrared MenuDynamic Masking UPH-Z Series only Position Recall Mask NRMask Changing Changing ColourPTZ Mode Masking 11.5 Creating a New Dynamic MaskSAT Back Light CompenImage Stabilization Load Default menu is used to load the default settings 11.6 Load Default Configuration11.7 Setup Info Menu UPH boards12.2 Replacing the Fuses Maintenance12.1 Cleaning Voltage Fuse F1 Fuse F2Problem Possible Cause Solution TroubleshootingTroubleshooting Error 13.1 Dimensions and Range of Movement 514 584R385 Technical Specifications Bosch Security Systems