Bosch Appliances UPH-Z, UPH-2D Area Parameters Menu, Enables / disables the on-screen message

Page 37

High Speed Pan/Tilt System

Configuring the System en 37

 

 

11.2.1Area Parameters Menu

The Area Parameters menu enables the user to show a message on the screen, depending on the horizontal position reached by the device; this is sometimes known as sector information. From this menu, it is possible to enter two (2) lower menus that are used to set the text for each area, and the start and end positions (in degrees) of these areas. It is possible to set up to eight (8) areas with their own title, start, and end positions.

For example, to activate the first title and obtain a message when the device is between +80 ° and +120 ° in the horizontal (pan) direction, proceed as follows:

1.Enter the Position Area menu.

2.Select Area 1 by pressing Focus; an arrow starts blinking next to the start position. Press Focus again, use the joystick to enter the value +080.00 in the left column (start position of text coming on screen), then press Focus to store that value. Repeat the process, but put +120.00 in the right column (stop position of text removed from the screen).

3.In the Text (String) Area menu, select the first line and enter the desired text.

Note: If the area position start and end values are set to +0.00, this disables the text display.

AREA PARAMETERS MENU

 

 

 

 

 

TEXT AREA MENU

 

EDIT TEXT MENU

 

 

1 - AREA TITLE

:

NO

 

 

 

 1

- AREA 1

 

 1 - STRING EDIT

 

 

 

2 - STRING AREA MENU

 



 

 

 

 

2

- AREA 2

 

 

 

 

 

 

3 - POSITION AREA MENU



 

 

 

 

3

- AREA 3

 

------------------------------------------

 

 

 

 

 

 

 

 

 

4

- AREA 4

 

Test area 1

 

 

 

 

 

 

 

 

 

 

5

- AREA 5

 

------------------------------------------

 

 

 

 

 

 

 

 

 

6

- AREA 6

 

 

 

 

 

 

 

 

 

 

 

 

 

7

- AREA 7

 

2 - DELETE STRING

 

 

8 - OFFSET PAN :

+ 0.0

 

 

 

 

8

- AREA 8

 

 

 

 

 

 

 

 

 

 

 

 

 

Test area 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AREA POSITION MENU

 

 

 

 

 

 

 

 

 

 

 

 

 

1

- AREA 1 + 0.0 + 0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

2

- AREA 2 + 0.0 + 0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

3

- AREA 3 + 0.0 + 0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

4

- AREA 4 + 0.0 + 0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

5

- AREA 5 + 0.0 + 0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

6

- AREA 6 + 0.0 + 0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

7

- AREA 7 + 0.0 + 0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

8

- AREA 8 + 0.0 + 0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

Test area 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 11.4 Area Parameters Menu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Feature

 

 

 

 

 

 

 

Description

 

 

Default

Options

 

 

 

 

 

 

 

 

 

Enables / disables the on-screen message

 

 

 

 

AREA TITLE

 

depending on the horizontal position reached

NO

YES, NO

 

 

by the device.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enables the user to edit a customized, on-

 

 

 

 

STRING AREA MENU

 

screen text message that is activated when the

 

 

 

 

 

 

device reaches a defined, horizontal position.

 

 

 

 

 

 

 

 

 

 

 

POSITION AREA

 

The horizontal position reached by the device

 

 

 

 

 

that prompts a customized on-screen text

 

 

 

 

MENU

 

 

 

 

 

 

message.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adds a corresponding value (offset) in degrees

 

 

 

 

 

 

to the pan references used for displaying the

 

 

 

-180.00

 

 

area text. For example, if this value is set to

 

 

 

OFFSET PAN

 

 

+0.00

 

to

 

+45.0 ° then all references will be shifted in

 

 

 

 

 

 

 

+180.00

 

 

PAN by +45 ° with respect to the system’s

 

 

 

 

 

 

 

 

 

 

 

physical reference.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Security Systems

Instruction Manual

F01U.073.990 Version 1.0 2007.07

Image 37
Contents High Speed Pan/Tilt System Page Table of Contents Configuring the System Important safety instructions SafetySafety precautions Coax grounding Important noticesTrademarks Copyright2Unpacking Parts ListTools Required Small, straight-blade screwdriver 2.5 mm 0.13Description Safety RulesMounting the High Speed Pan/Tilt Installing the High Speed Pan/TiltWarranties are void Outdoor Pole Mount for UPH Series DescriptionOutdoor Wall Mount for UPH Series Pole Adapter for MTC-WUPHBase Gasket Screw Ring Washer Bracket Support Reference # DescriptionTie Threads used to Group and Secure Signal Cables Wiring the Video CableThat the disconnecting switch is open Connecting the Power SupplyWire Color VAC Terminal Connection Per local Installer Neutral Live/Active Green/Yellow EarthRS-232 is used for firmware upgrades only see Figure Wiring Biphase5RS-232 Connecting the Washer Pump optional Nut Washer PipeNosecap CouplingCalibrating the Nozzle AL1 Reference DescriptionBase with 19-pin Connector for Connecting Peripherals Connecting the PeripheralsAttaching the Top Unit Metal Fixing AccessorySalt Bag Fixing ScrewsAligning the Tabs Place safety label near unit that warns of moving parts Configuration WindowScrew Screw SealBaud Rate Switches Configuring the DeviceRocker for DIP switch No is OFF PROGRAM. OFF For updating the firmwareSetting the Address Protocol SwitchesProtocol Baud Rate Menu setup OSD Pelco D 2400 Preset Biphase Auto AUX-On BilinxAddress Combinations 4Connections RS-485 Biphase Bilinx/Video Intuikeyboard RS-485 Divar BiphaseIntuikeyboard AllegiantEthernetEthernet Video RS485-2Configuring the Device Switching On and OffTo configure the UPH, proceed as follows On-screen Display OSD Using the JoystickMoving Around the Menus Open or Iris Close buttonSetup and Configuration 10.1 Keyboard Commands ListPresets Auxiliary Connections10.2 Changing the Settings Configuring the System10.3 Changing the Numeric Fields Main menu by pressing AUX on 200 Enter11.1 Language Menu 11.2 Display Setup MenuPlayed on the screen Feature Description Default Options By the device Enables the user to edit a customized, on Enables / disables the on-screen messageArea Parameters Menu Depending on the horizontal position reachedChanging the Edit Text Menu Setting the Area Position ValuesOffset Pan Display Parameters11.3 Motion Parameters Menu Wiper-washer, and the alarm settings of the UPHSpeed Menu PAN Speed Data is expressed as degrees per secondTilt Speed Limits Feature Description Preset/Patrol/AutopanPreset Menu Special Preset Parameters Reached Speed Home PositionStart Position Patrol loading of preset positionsEND Position First Prst SpeedAutopan Autopan menu is used to indicate preset position settingsMotions Recall Menu Wiper-Washer 11.4 Camera Parameters AlarmsUPH-2D and UPH-3D Series DinionXF Cameras Zoom Parameters Menu UPH-Z Series camera moduleFocus Parameters Menu Focus Parameters menu is used to enable focus settingsAuto Exposure Parameters Menu Parameters Mode Infrared MenuDynamic Masking UPH-Z Series only Mask Changing Mask NRPosition Recall Changing Colour11.5 Creating a New Dynamic Mask PTZ Mode MaskingSAT Back Light CompenImage Stabilization 11.7 Setup Info Menu 11.6 Load Default ConfigurationLoad Default menu is used to load the default settings UPH boards12.1 Cleaning Maintenance12.2 Replacing the Fuses Voltage Fuse F1 Fuse F2Problem Possible Cause Solution TroubleshootingTroubleshooting Error 514 584 13.1 Dimensions and Range of MovementR385 Technical Specifications Bosch Security Systems